Definitionintro
Radon transform
The map that takes a function on the plane to its integrals along all lines, indexed by the angle and the signed distance of the line from the origin.
The Radon transform takes a function on the plane to the set of its integrals along all lines. It is the forward operator of parallel-beam CT, where each line integral is the log of an X-ray intensity ratio by the Beer-Lambert law. In the plane it is the same object as the X-ray transform; in dimensions the Radon transform integrates over hyperplanes, the X-ray transform over lines. The parabolic Radon transform of seismic processing is a different transform: it sums a data gather along parabolas in time and offset, not a function along straight lines.
Definition
Let and . For , the Radon transform of is the function
The integral runs over the line , that is, . The number is the signed distance of the line from the origin, and is its unit normal. By Fubini's theorem the integral exists for almost every , and for each . For a continuous with compact support it exists for every . The function for one fixed is the projection at the angle .
The pair gives the same line as , so if is allowed in then and each line appears twice. This page and the other tomography pages use and , the convention of Kak and Slaney. Natterer writes for the unit vector itself, on the circle .
In the Radon transform integrates over hyperplanes: for , where is the -dimensional surface measure. For this is the definition above.
Some properties follow at once from the definition. They hold for every .
- Linear. .
- Shift. If , then . A shift of the object shifts each projection by the component of along .
- Rotation. If is rotated by the angle , then , with the angle taken modulo together with the sign rule above. A radial has the same projection at each angle.
- Mass. for each .
- Moments. For each integer , , which is a homogeneous polynomial of degree in and when the moments of exist. These are the Helgason-Ludwig range conditions (Natterer, Section II.4). A function that fails them is not the Radon transform of any function, so noisy data are in general outside the range.
- Bounded on a disk. If vanishes outside the unit disk, the Cauchy-Schwarz inequality on a chord of length at most 2 gives . Integration over and over gives in . So is a bounded operator from of the disk to . Its adjoint is the back-projection operator.
Examples and non-examples
The unit disk. Let on and 0 outside. The line at distance cuts the disk in a chord of length , so for and 0 otherwise, at each angle. The mass check gives , the area of the disk.
An ellipse. Let on the ellipse and 0 outside. Put . Then
and 0 otherwise (Kak and Slaney, equation 5). For , , , and : and . The shift and rotation rules then give the projection of any ellipse, and a sum of ellipses gives the projection of the Shepp-Logan phantom in closed form.
The Gaussian. For , the integral along each line is . Its 1D Fourier transform is , which is the 2D transform of on the line through the origin, as the Fourier slice theorem says.
A point. A unit point mass at is not a function, but the limit of narrow bumps gives the distribution : the projection is a spike at . As goes from 0 to , the spike traces a sinusoid. This is the origin of the name sinogram for the image of .
Non-example: the constant function. on all of is not in , and every line integral is infinite. The definition needs decay or compact support.
Non-example: a discrete projector. A pixel-driven or ray-driven matrix, such as the Siddon algorithm or the Joseph projector, is a discretization of for a pixel image, not the transform itself. Its rows differ from the exact line integrals by a discretization error, and its adjoint is a discrete back projection.
Non-example: Radon's theorem on convex sets. Radon's theorem in convex geometry (any points in split into two sets whose convex hulls meet) carries the same name but has no relation to this transform.
Related definitions
- X-ray transform: integrals over lines in . It equals the Radon transform for .
- Sinogram: the data shown as an image over .
- Back-projection operator: the adjoint , which sums over all lines through a point.
- Fourier slice theorem: the 1D transform of a projection is a line of the 2D transform of .
- Radon inversion formula: from , by a filter in and back projection.
- Attenuated Radon transform: the line integrals with an exponential weight, the model of SPECT.
- Hough transform: a discrete relative that votes for lines through the edge points of an image.
- Tomographic reconstruction problem: the inverse problem of finding from samples of .
References
- J. Radon, Über die Bestimmung von Funktionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten, Berichte über die Verhandlungen der Königlich-Sächsischen Gesellschaft der Wissenschaften zu Leipzig, Math.-Phys. Klasse 69, 1917, pages 262 to 277, the definition of the line integrals of a function on the plane and their inversion
- F. Natterer, The Mathematics of Computerized Tomography, SIAM Classics in Applied Mathematics 32, 2001, Section II.1, definition and elementary properties of some integral operators; Section II.4, the ranges
- A. C. Kak and M. Slaney, Principles of Computerized Tomographic Imaging, SIAM Classics in Applied Mathematics 33, 2001, Chapter 3, Section 3.1, pp. 49 to 56 (line integrals and projections, the Shepp-Logan phantom of Fig. 3.4 and the projection of an ellipse, equation 5)
- A. M. Cormack, Representation of a function by its line integrals, with some radiological applications, Journal of Applied Physics 34(9), 1963, pp. 2722 to 2727
Where this leads
- Attenuated Radon transform
- Back-projection operator
- Common lines method
- Direct Fourier reconstruction
- Distance-driven projector
- Emission tomography model
- Fan-beam filtered back-projection
- Fan-to-parallel rebinning
- Filtered back-projection
- Fourier slice theorem
- Grangeat's formula
- Interior tomography
- Joseph's projector
- Lambda tomography
- Limited-angle tomography
- Photoacoustic tomography
- Shepp-Logan phantom
- Siddon's algorithm
- Single-particle reconstruction
- Sinogram
- Sparse-view CT reconstruction
- Tomographic reconstruction
- X-ray transform
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W4 complete |
|
Tag 27X3XV Edit this page History Report an error Markdown