Algorithm Search⌘K

Tomographic reconstruction

Problems

  • Tomographic reconstruction

    Recover a function on the plane or in space from its integrals along many lines or planes, such as the X-ray attenuation map from CT projections.

    intro
  • Calderon problem

    Recover the conductivity inside a body from the map that sends boundary voltages to boundary currents, a severely ill-posed nonlinear problem.

    advanced
  • Discrete tomography

    Reconstruct an image with few gray values, such as a 0-1 matrix, from a few projections. Two directions are easy, and consistency for three or more is NP-complete.

    advanced
  • Interior tomography

    Reconstruct a region inside the object from the rays that pass through it only, which is not unique without extra prior information.

    advanced
  • Limited-angle tomography

    Reconstruct from projections over an angular range less than 180 degrees, which leaves a wedge of Fourier space unmeasured and only edges in some directions stable.

    advanced
  • Metal artifact reduction

    Remove the streaks that metal implants cause in CT, usually by finding the corrupted rays and replacing or reweighting them before reconstruction.

    advanced
  • Single-particle reconstruction

    Recover a 3D molecule density from many noisy 2D cryo-electron microscope projections taken at unknown orientations.

    advanced
  • Sparse-view CT reconstruction

    Reconstruct a CT image from far fewer projection angles than the sampling condition asks, which needs a prior such as small total variation.

    advanced

Algorithms

  • Direct Fourier reconstruction

    Reconstruct a CT slice from the 1D transforms of its projections. Place them on radial lines, interpolate onto a Cartesian grid and take an inverse 2D FFT.

    O(a d log d + n^2 log n) worst1 languagescore
  • Fan-beam filtered back-projection

    Reconstruct a CT slice from rays that diverge from a point source. Weight each projection, filter it with a modified ramp, and back-project with the inverse squared source distance.

    O(a d log d + a n^2) worst1 languagescore
  • Fan-to-parallel rebinning

    Turn fan-beam CT data into a parallel-beam sinogram. Each parallel ray is a fan ray with a known source angle and fan angle, read from the fan data by interpolation.

    O(a d) worst1 languagescore
  • Feldkamp-Davis-Kress algorithm

    Approximate cone-beam CT reconstruction for a circular source orbit. Weight each projection, ramp-filter it row by row, and back-project it in 3D with the inverse squared depth.

    O(a m d log d + a s n^2) worst1 languagescore
  • Filtered back-projection

    Reconstruct a CT slice from parallel projections. Convolve each projection with a band-limited ramp kernel, then back-project the filtered projections over all angles.

    O(a d log d + a n^2) worst1 languagescore
  • Maximum likelihood expectation maximization reconstruction

    Maximize the Poisson likelihood of emission data by multiplying the image by the back-projected ratio of measured to predicted counts, keeping it nonnegative.

    O(K a d n) total1 languagescore
  • Ordered subsets expectation maximization

    Speed up MLEM by applying its multiplicative update with one subset of projections at a time, cycling through the subsets.

    O(K (a d n + T n^2)) total1 languagescore
  • Siddon's algorithm

    Compute the exact length of a ray in each pixel or voxel it crosses, by merging the sorted parameters of its crossings with the grid lines or planes.

    O(a d n) worst1 languagescore
  • Simultaneous algebraic reconstruction technique

    Update the image by the normalized back projection of the residuals of one whole projection angle at a time, between ART and SIRT.

    O(K a d n) total1 languagescore
  • Simultaneous iterative reconstruction technique

    Update all pixels at once by the back projection of all ray residuals, scaled by the row and column sums of the system matrix. It is a weighted Landweber iteration.

    O(K a d n) total1 languagescore
  • Common lines method

    Find the relative orientations of projection images from the lines along which pairs of their 2D Fourier transforms agree, as the slice theorem requires.

    O(m a n^2 + m^2 a^2 d + m^4) total1 languagesadvanced
  • Distance-driven projector

    A matched forward and back projector for CT that maps pixel borders and detector bin borders onto one axis and uses the lengths of their overlaps as weights.

    O(a n (n + d)) worst1 languagesadvanced
  • Joseph's projector

    Approximate a line integral through an image by linear interpolation between the two nearest pixel centers on each row or column the ray crosses.

    O(a d n) worst1 languagesadvanced
  • Lambda tomography

    Reconstruct Lambda f, the square root of minus the Laplacian of f, from local data. It is not f, but it has the same edges, and each value needs only the rays near the point.

    O(a d + a n^2) worst1 languagesadvanced
  • One-step-late algorithm

    Add a prior to MLEM by evaluating the gradient of the penalty at the current image in the denominator of the update.

    O(K a d n) total1 languagesadvanced
  • Separable paraboloidal surrogates

    Minimize penalized likelihood for transmission or emission tomography by minimizing at each step a separable quadratic surrogate that majorizes the cost.

    O(K a d n) total1 languagesadvanced
  • Adaptive steepest descent POCS

    Reconstruct sparse-view CT by alternating projections onto the data and positivity constraints with steepest descent steps on total variation.

    O(K (a d n + g n^2)) total1 languagesresearch
  • D-bar method

    Reconstruct a 2D conductivity from boundary data through scattering transforms and a d-bar equation, a direct nonlinear method for EIT.

    O(m c^2 + n^2 K m^2) total1 languagesresearch
  • Katsevich algorithm

    Exact helical cone-beam CT reconstruction. Differentiate the data along the source path, apply a 1D Hilbert filter along kappa-lines, and back-project over the PI-interval of each point.

    O(a m d + V K d) worst1 languagesresearch

Concepts

  • Beam hardening

    The rise in mean energy of a polychromatic X-ray beam as it passes through matter, which breaks the linear model and causes cupping and streaks.

    advanced

Definitions

  • Radon transform

    The map that takes a function on the plane to its integrals along all lines, indexed by the angle and the signed distance of the line from the origin.

    intro
  • Shepp-Logan phantom

    A standard test image of ten ellipses that models a head section, whose Radon transform is known in closed form.

    intro
  • Sinogram

    The Radon transform data shown as an image over angle and detector position, where each point of the object traces a sinusoid.

    intro
  • Back-projection operator

    The adjoint of the Radon transform, which sets each point to the sum of the projection values on all lines through it and gives a blurred image.

    core
  • Ramp filter

    The filter with frequency response |sigma| that undoes the 1/r blur of back-projection, often multiplied by a window to limit noise.

    core
  • X-ray transform

    The map that takes a function in n dimensions to its integrals along lines, equal to the Radon transform in the plane and different from it in space.

    core
  • Attenuated Radon transform

    The Radon transform with an exponential weight from the attenuation along each line, the model of SPECT data.

    advanced

Theorems

  • Beer-Lambert law

    The intensity of a ray through matter falls as the exponential of minus the line integral of the attenuation, which makes CT data line integrals after a log.

    intro
  • Fourier slice theorem

    The 1D Fourier transform of a parallel projection at angle theta equals the 2D Fourier transform of the object along the line through the origin at that angle.

    core
  • Radon inversion formula

    A function is recovered from its Radon transform by applying the Hilbert transform and a derivative in the radial variable, then back-projecting.

    core
  • Grangeat's formula

    The radial derivative of the 3D Radon transform is given by a weighted derivative of cone-beam line integrals, which links cone-beam data to plane integrals.

    advanced
  • Tuy condition

    Exact cone-beam reconstruction is possible when every plane through the object meets the source trajectory, which a single circle fails.

    advanced
  • Novikov inversion formula

    An explicit formula that inverts the attenuated Radon transform in the plane for a known attenuation map, found by Novikov in 2002.

    research

Models

  • Emission tomography model

    Model the counts of each detector bin as independent Poisson variables whose means are weighted line sums of the unknown activity map plus a known background.

    core