Algorithm Search⌘K

Problemadvanced

Sparse-view CT reconstruction

Also called few-view tomography, sparse-view CT.

Reconstruct a CT image from far fewer projection angles than the sampling condition asks, which needs a prior such as small total variation.

Sparse-view CT reconstruction asks for a CT image from projections at only a few angles, far fewer than the sampling condition of filtered back-projection needs. The motive is a lower X-ray dose or a faster scan. With few angles, the linear system Ax=yA x = y has fewer equations than unknowns, so many images fit the data exactly, and the angular gaps alias into streaks in the FBP image. No method can recover a general image from the data alone. Every method adds a prior: nonnegativity, a small total variation, a sparse representation, or a model learned from training images. The best-known approach, minimizing total variation under a data constraint, comes from compressed sensing.

In plain words

A CT scanner sends X-rays through the body from many angles and records how much each ray is weakened. From these records, a computer builds a cross-section image. The usual method needs many angles, about one and a half times the number of detector cells across the body. Each angle costs radiation.

With only a few angles, the records do not pin down the image. Many different images give exactly the same records, and the usual method fills the gaps with straight streaks. To choose one image, the computer must use knowledge about what real images look like. Real cross-sections are made of a few organs or materials, each with a nearly constant value, so a good choice is the image with the fewest and smallest jumps in value that still matches the records.

Definition

Let ff be the unknown attenuation on the unit disk, and Rf(θ,s)\mathcal{R}f(\theta, s) its Radon transform. The data are noisy samples

yk,j=Rf(θk,sj)+ek,j,k=0,…,a−1,j=0,…,d−1,y_{k,j} = \mathcal{R}f(\theta_k, s_j) + e_{k,j}, \qquad k = 0, \dots, a - 1,\quad j = 0, \dots, d - 1,

at aa angles θk=kπ/a\theta_k = k\pi/a and dd detector bins, with the noise norm ∥e∥≤δ\|e\| \le \delta. Discretized on an n×nn \times n grid, the model is y=Ax+ey = A x + e with a nonnegative system matrix AA of size ad×n2ad \times n^2 (from Siddon's algorithm, Joseph's projector or the distance-driven projector). The problem is sparse-view when the number of angles aa is far below the sampling condition a≈πd/2a \approx \pi d/2 of the parallel geometry (Natterer, Chapter III). In practice this means tens of angles instead of hundreds or a thousand.

The output is an image xx that fits the data and is close to the true image. The standard formulation with a total variation prior is the convex problem

min⁡xTV⁡(x)subject to∥Ax−y∥≤ε,x≥0,\min_x \operatorname{TV}(x) \quad\text{subject to}\quad \|A x - y\| \le \varepsilon,\quad x \ge 0,

with ε≈δ\varepsilon \approx \delta, or its penalized form min⁡x12∥Ax−y∥2+μTV⁡(x)\min_x \frac{1}{2}\|A x - y\|^2 + \mu \operatorname{TV}(x) over x≥0x \ge 0.

What the data do not fix. If ad<n2a d < n^2, the null space of AA has dimension at least n2−adn^2 - a d, and adding any null space vector to a solution gives another solution. This is a statement about the discrete model. In the continuous model it is stronger: Smith, Solmon and Wagner (1977) showed that for any finite set of directions there are nonzero smooth functions with compact support whose projections in all these directions vanish. So finitely many projections never determine a general object.

Variants

  • Fan-beam and cone-beam geometry. The same problem with divergent rays. Sidky and Pan studied the circular cone-beam case.
  • Limited angle. The few angles are not spread over [0,π)[0, \pi) but bunched in a smaller range. This is a different and harder problem with a missing wedge in Fourier space; see limited-angle tomography.
  • Interior and truncated data. Few views combined with a detector that does not cover the object; see interior tomography.
  • Low dose. Many angles with high noise per ray instead of few angles. The trade between the number of views and the dose per view is a design question.
  • Discrete objects. If the object takes only a few known values, the problem becomes discrete tomography, which needs even fewer views.

Examples

A null space in a 2 by 2 image. Take the image x=(x0,x1;x2,x3)x = (x_0, x_1; x_2, x_3) and two views, the row sums and the column sums. The matrix has 4 rows and rank 3, and its null space is spanned by the checkerboard c=(1,−1;−1,1)c = (1, -1; -1, 1), because each row and each column of cc sums to 0. For the true image x=(2,0;0,0)x = (2, 0; 0, 0), the data are the row sums (2,0)(2, 0) and the column sums (2,0)(2, 0), and every image x+tc=(2+t,−t;−t,t)x + t c = (2 + t, -t; -t, t) fits them exactly.

  • The minimum-norm solution, which SIRT or ART give from x0=0x_0 = 0, removes the part of xx along cc: ⟨x,c⟩/∥c∥2=2/4=1/2\langle x, c\rangle / \|c\|^2 = 2/4 = 1/2, so it is (3/2,1/2;1/2,−1/2)(3/2, 1/2; 1/2, -1/2). It has a negative value, which is impossible for an attenuation.
  • Nonnegativity alone fixes the answer here: 2+t≥02 + t \ge 0, −t≥0-t \ge 0 and t≥0t \ge 0 force t=0t = 0.
  • The anisotropic total variation, the sum of the absolute differences of the four neighbor pairs, is 2∣2+2t∣+2∣2t∣=4(∣1+t∣+∣t∣)2|2 + 2t| + 2|2t| = 4(|1 + t| + |t|). It is smallest, with the value 4, for all t∈[−1,0]t \in [-1, 0], so TV alone does not decide, but TV together with nonnegativity gives t=0t = 0.

A measured case. A 16×1616 \times 16 phantom of three ellipses (values 0 to 1.5), 6 angles with 23 bins each, 138 equations for 256 unknowns, and exact data. ART with positivity reaches the relative error 0.068 after 200 sweeps and stays near 0.067. ASD-POCS, which adds TV steps, reaches 0.050 after 200 iterations and 0.037 after 400 with one parameter set (g=10g = 10, α=0.05\alpha = 0.05). These are measurements of this setup, made with the code of the ASD-POCS page.

Known algorithms

Method Prior What it gives
Filtered back-projection none fast and linear; with few views, streaks from angular aliasing (Kak and Slaney, Chapter 5)
ART, SART, SIRT the start point, early stopping a solution near the start in a weighted norm; fewer streaks than FBP, but the null space error stays
ASD-POCS (Sidky and Pan 2008) TV and nonnegativity alternating data and TV steps with adaptive lengths; a heuristic without a convergence proof
Chambolle-Pock algorithm (Sidky, Jorgensen and Pan 2012) TV, constrained or penalized a primal-dual method that converges to a solution of the convex problem
ADMM, split Bregman TV or other sparsity priors splitting methods for the penalized problem, with convergence proofs
Total generalized variation piecewise smooth images less staircasing than TV, at a higher cost
Learned primal-dual, algorithm unrolling learned from training data trained iterations that use the projector and its adjoint; no guarantee outside the training distribution
Plug-and-play priors, deep image prior a denoiser or a network structure a prior given by a denoiser or by the bias of a network; convergence only under conditions on the denoiser

Bounds

  • Counting (theorem). With ad<n2a d < n^2 equations, the discrete null space has dimension at least n2−adn^2 - a d, so no method that uses only the data can recover every image.
  • Finite data in the continuum (theorem). No finite set of projections determines a general compactly supported function (Smith, Solmon and Wagner 1977). Every positive result needs a restricted class of images.
  • Sampling (theorem with assumptions). For an image of bandwidth bb on the unit disk, the parallel geometry resolves it with about a≈πd/2a \approx \pi d/2 angles and a detector spacing of about 1/(2b)1/(2b) (Natterer, Chapter III). Sparse-view CT lives far below this count.
  • Sparse gradients (theorem for random Fourier samples). Candes, Romberg and Tao proved (their theorem) that a signal whose gradient has ss nonzero entries is recovered exactly by TV minimization from a number of randomly chosen Fourier samples of order slog⁡Ns \log N, with high probability. CT data on a few angles give Fourier samples on a few radial lines (the Fourier slice theorem), which are not random, so the theorem does not cover CT. Their exact recovery of a phantom from radial lines was a numerical experiment, not a theorem.
  • Heuristic rules. How many views TV reconstruction needs for a given class of images is known from experiments and from studies of phase transitions, not from a theorem for CT geometry.

Reductions

  • To a convex program. The TV problem with ∥Ax−y∥≤ε\|A x - y\| \le \varepsilon and x≥0x \ge 0 is a second-order cone program, so interior-point methods solve it for small images, and first-order methods such as Chambolle-Pock for large ones.
  • To compressed sensing. By the Fourier slice theorem, each view gives the 2D Fourier transform of the image on one line through the origin. With a gridding step, sparse-view CT becomes recovery of an image with a sparse gradient from Fourier samples on radial lines.
  • To sinogram inpainting. Treat the missing angles as missing rows of the sinogram, fill them by inpainting or interpolation, and then run FBP. This uses the structure of sinograms rather than of images.
  • To discrete tomography. If the image takes only the values 0 and 1, sparse-view CT is discrete tomography, where two directions can already be enough in special cases, and three directions make the decision problem NP-complete.

Applications

  • Low-dose medical CT. Fewer views lower the dose for screening and for children, at the price of a prior.
  • Fast and gated scans. In cardiac CT and in perfusion studies, only the views taken during a short time window are usable.
  • Industrial and security CT. Inspection of parts made of a few materials, where TV and discrete priors fit well and scan time is limited.
  • Electron and X-ray microscopy. Tilt series with few projections because the sample is damaged by the beam; usually combined with a limited angle range.
  • Tomosynthesis. Breast and chest tomosynthesis take few views over a limited range, so they combine the sparse-view and limited-angle problems.

References

  1. K. T. Smith, D. C. Solmon and S. L. Wagner, Practical and mathematical aspects of the problem of reconstructing objects from radiographs, Bulletin of the American Mathematical Society 83(6), 1977, pp. 1227 to 1270 (finitely many projections do not determine an object)
  2. F. Natterer, The Mathematics of Computerized Tomography, SIAM Classics in Applied Mathematics 32, 2001, Chapter III (sampling conditions for the parallel scanning geometry and resolution)
  3. A. C. Kak and M. Slaney, Principles of Computerized Tomographic Imaging, SIAM Classics in Applied Mathematics 33, 2001, Chapter 5 (aliasing artifacts in CT images, including too few views) and Chapter 7 (algebraic reconstruction)
  4. Emmanuel J. Candes, Justin Romberg and Terence Tao, Robust uncertainty principles, exact signal reconstruction from highly incomplete frequency information, IEEE Transactions on Information Theory 52(2), 2006, exact recovery of a piecewise constant image from incomplete Fourier samples by TV minimization (general locator)
  5. Emil Y. Sidky and Xiaochuan Pan, Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization, Physics in Medicine and Biology 53(17), 2008, the constrained TV problem for few-view CT and the ASD-POCS algorithm (general locator)
  6. Emil Y. Sidky, Jakob H. Jorgensen and Xiaochuan Pan, Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle-Pock algorithm, Physics in Medicine and Biology 57(10), 2012, convergent primal-dual solvers for the constrained and penalized TV problems of CT (general locator)

About this page

The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.

LadderLevelWhat the next level needs
Human proofH0 no proof
  • add a proof in proofs/ (06.5)
LeanL0 no Lean part
  • name a Lean module in the lean field (07)
VisualV0 none
  • add viz/scene.ts or a figure (10)
WritingW2 basic
  • a known algorithm
  • a contract.yaml