Definitionadvanced
Attenuated Radon transform
The Radon transform with an exponential weight from the attenuation along each line, the model of SPECT data.
The attenuated Radon transform is the model of single photon emission computed tomography (SPECT). A tracer with activity sends out photons, and a photon that starts at and moves toward the detector is absorbed on its way with a rate , the attenuation map. By the Beer-Lambert law, the photon reaches the detector with the probability , where the integral runs from to the detector. So each measured line integral of has a weight that depends on the point and on the direction of travel. With it is the Radon transform. For a known , the Novikov inversion formula recovers exactly.
Definition
Let and , as on the Radon transform page. For an attenuation map and a direction , the divergent beam transform is
the integral of on the half line from in the direction . For and continuous with compact support, the attenuated Radon transform of is
with and . The integral runs over the line , as for the Radon transform. The weight is the fraction of the photons from the point that reach a detector far away in the direction . This is the convention of Natterer; other papers put the detector on the other side, which changes to .
The angle runs over the full circle . The pairs and give the same line, but the photons move in opposite directions, so the weights differ. In general , and the data on do not determine the data on . A SPECT camera that turns through degrees measures both.
Some properties follow from the definition.
- Linear in . for a fixed .
- Not linear in . The map is nonlinear, because is in an exponent. Finding both and from alone is a different and harder problem.
- Reduces to the Radon transform. For , for every .
- Bounded by the Radon transform. Since , the weight is in , so for .
- Adjoint. For a fixed , the adjoint is the attenuated back projection . It is the back-projection operator with the same weight.
- A discrete form. A system matrix for SPECT puts the weight , computed for each pixel and each direction, into the row of each ray. The result is a nonnegative matrix for the emission tomography model, and MLEM applies to it directly.
Examples and non-examples
A uniform disk. Let and on the unit disk, and 0 outside. Put for . The line at distance meets the disk for , and the photon from the point crosses the length of the disk on its way out. So
At and this is , against the Radon value . As it tends to , the Radon transform of the disk. Here the data do not depend on , and they are the same for and , because the object and the attenuation are symmetric.
A point source off center. Let be a unit point mass at , and on the unit disk. Then . At , , and the photon crosses the length of the disk: the weight is . At , which gives the same line, and the length is : the weight is . The two directions of one line give different data. This is why the full circle of angles is needed.
Non-example: PET data. In positron emission tomography the two photons of one event move in opposite directions along the same line, and both must reach the detectors. The product of the two weights is , the same for every point of the line. So PET data are : the Radon transform times a known factor, which a transmission scan measures. It is not an attenuated Radon transform in the sense above, and the attenuation correction is a division.
A special case: constant attenuation. If on a known convex region that holds the support of , the weight can be split into a factor that depends only on the line and the factor . After this correction the data are the exponential Radon transform . Tretiak and Metz (1980) inverted it with a filtered back projection with a modified filter.
Non-example: a transmission scan. In transmission CT the source is outside the body, and the data are for the attenuation itself. Taking the log gives the Radon transform of . There is no emission activity and no weight inside the integral.
Related definitions
- Radon transform: the case .
- X-ray transform: the line integrals in any dimension; the attenuated X-ray transform adds the same weight.
- Novikov inversion formula: the explicit inverse of in the plane for a known .
- Radon inversion formula: the inverse for , which the Novikov formula reduces to.
- Hilbert transform: the filter in that appears in both inversion formulas.
- Emission tomography model: the Poisson model for the counts, where a discrete is the system matrix of SPECT.
- Sinogram: the data shown as an image over ; for SPECT it covers .
References
- R. G. Novikov, An inversion formula for the attenuated X-ray transformation, Arkiv for Matematik 40(1), 2002, pp. 145 to 167 (the attenuated transform in the plane and its explicit inversion)
- F. Natterer, Inversion of the attenuated Radon transform, Inverse Problems 17(1), 2001, pp. 113 to 119 (the definition with the divergent beam transform, and a short derivation of the inversion)
- O. Tretiak and C. Metz, The exponential Radon transform, SIAM Journal on Applied Mathematics 39(2), 1980, pp. 341 to 354 (the case of a constant attenuation and its inversion)
- F. Natterer and F. Wubbeling, Mathematical Methods in Image Reconstruction, SIAM, 2001, Chapter 2, Integral Geometry, pp. 9 to 40 (the attenuated Radon transform among the integral transforms of tomography; general locator)
Where this leads
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W4 complete |
|
Tag KJR2GS Edit this page History Report an error Markdown