Algorithm Search⌘K

Definitionadvanced

Attenuated Radon transform

The Radon transform with an exponential weight from the attenuation along each line, the model of SPECT data.

The attenuated Radon transform is the model of single photon emission computed tomography (SPECT). A tracer with activity f(x)f(x) sends out photons, and a photon that starts at xx and moves toward the detector is absorbed on its way with a rate μ\mu, the attenuation map. By the Beer-Lambert law, the photon reaches the detector with the probability exp⁡(−∫μ)\exp(-\int \mu), where the integral runs from xx to the detector. So each measured line integral of ff has a weight that depends on the point and on the direction of travel. With μ=0\mu = 0 it is the Radon transform. For a known μ\mu, the Novikov inversion formula recovers ff exactly.

Definition

Let ω(θ)=(cos⁡θ,sin⁡θ)\omega(\theta) = (\cos\theta, \sin\theta) and ω⊥(θ)=(−sin⁡θ,cos⁡θ)\omega^\perp(\theta) = (-\sin\theta, \cos\theta), as on the Radon transform page. For an attenuation map μ≥0\mu \ge 0 and a direction vv, the divergent beam transform is

Dμ(x,v)=∫0∞μ(x+τv) dτ,D\mu(x, v) = \int_0^\infty \mu(x + \tau v)\,d\tau,

the integral of μ\mu on the half line from xx in the direction vv. For ff and μ\mu continuous with compact support, the attenuated Radon transform of ff is

Rμf(θ,s)=∫−∞∞f(s ω+t ω⊥) e−Dμ(sω+tω⊥, ω⊥) dt,θ∈[0,2π), s∈R,\mathcal{R}_\mu f(\theta, s) = \int_{-\infty}^{\infty} f(s\,\omega + t\,\omega^\perp)\, e^{-D\mu(s\omega + t\omega^\perp,\ \omega^\perp)}\,dt, \qquad \theta \in [0, 2\pi),\ s \in \mathbb{R},

with ω=ω(θ)\omega = \omega(\theta) and ω⊥=ω⊥(θ)\omega^\perp = \omega^\perp(\theta). The integral runs over the line x⋅ω=sx \cdot \omega = s, as for the Radon transform. The weight e−Dμe^{-D\mu} is the fraction of the photons from the point sω+tω⊥s\omega + t\omega^\perp that reach a detector far away in the direction ω⊥\omega^\perp. This is the convention of Natterer; other papers put the detector on the other side, which changes ω⊥\omega^\perp to −ω⊥-\omega^\perp.

The angle runs over the full circle [0,2π)[0, 2\pi). The pairs (θ,s)(\theta, s) and (θ+π,−s)(\theta + \pi, -s) give the same line, but the photons move in opposite directions, so the weights differ. In general Rμf(θ+π,−s)≠Rμf(θ,s)\mathcal{R}_\mu f(\theta + \pi, -s) \ne \mathcal{R}_\mu f(\theta, s), and the data on [0,π)[0, \pi) do not determine the data on [π,2π)[\pi, 2\pi). A SPECT camera that turns through 360360 degrees measures both.

Some properties follow from the definition.

  • Linear in ff. Rμ(αf+βg)=α Rμf+β Rμg\mathcal{R}_\mu(\alpha f + \beta g) = \alpha\,\mathcal{R}_\mu f + \beta\,\mathcal{R}_\mu g for a fixed μ\mu.
  • Not linear in μ\mu. The map μ↦Rμf\mu \mapsto \mathcal{R}_\mu f is nonlinear, because μ\mu is in an exponent. Finding both ff and μ\mu from Rμf\mathcal{R}_\mu f alone is a different and harder problem.
  • Reduces to the Radon transform. For μ=0\mu = 0, R0f(θ,s)=Rf(θ,s)\mathcal{R}_0 f(\theta, s) = \mathcal{R}f(\theta, s) for every θ∈[0,2π)\theta \in [0, 2\pi).
  • Bounded by the Radon transform. Since μ≥0\mu \ge 0, the weight is in (0,1](0, 1], so 0≤Rμf≤Rf0 \le \mathcal{R}_\mu f \le \mathcal{R}f for f≥0f \ge 0.
  • Adjoint. For a fixed μ\mu, the adjoint is the attenuated back projection Rμ#g(x)=∫02πe−Dμ(x,ω⊥(θ)) g(θ,x⋅ω(θ)) dθ\mathcal{R}_\mu^\# g(x) = \int_0^{2\pi} e^{-D\mu(x, \omega^\perp(\theta))}\, g(\theta, x \cdot \omega(\theta))\,d\theta. It is the back-projection operator with the same weight.
  • A discrete form. A system matrix for SPECT puts the weight e−Dμe^{-D\mu}, computed for each pixel and each direction, into the row of each ray. The result is a nonnegative matrix for the emission tomography model, and MLEM applies to it directly.

Examples and non-examples

A uniform disk. Let f=1f = 1 and μ=μ0\mu = \mu_0 on the unit disk, and 0 outside. Put h=1−s2h = \sqrt{1 - s^2} for ∣s∣≤1|s| \le 1. The line at distance ss meets the disk for t∈[−h,h]t \in [-h, h], and the photon from the point tt crosses the length h−th - t of the disk on its way out. So

Rμf(θ,s)=∫−hhe−μ0(h−t) dt=1−e−2μ0hμ0.\mathcal{R}_\mu f(\theta, s) = \int_{-h}^{h} e^{-\mu_0 (h - t)}\,dt = \frac{1 - e^{-2\mu_0 h}}{\mu_0}.

At μ0=1\mu_0 = 1 and s=0s = 0 this is 1−e−2=0.8646651 - e^{-2} = 0.864665, against the Radon value 22. As μ0→0\mu_0 \to 0 it tends to 2h2h, the Radon transform of the disk. Here the data do not depend on θ\theta, and they are the same for (θ,s)(\theta, s) and (θ+π,−s)(\theta + \pi, -s), because the object and the attenuation are symmetric.

A point source off center. Let ff be a unit point mass at x0=(0.5,0)x_0 = (0.5, 0), and μ=1\mu = 1 on the unit disk. Then Rμf(θ,s)=δ(s−x0⋅ω) e−Dμ(x0,ω⊥)\mathcal{R}_\mu f(\theta, s) = \delta(s - x_0\cdot\omega)\, e^{-D\mu(x_0, \omega^\perp)}. At θ=π/2\theta = \pi/2, ω⊥=(−1,0)\omega^\perp = (-1, 0), and the photon crosses the length 1.51.5 of the disk: the weight is e−1.5=0.2231e^{-1.5} = 0.2231. At θ=3π/2\theta = 3\pi/2, which gives the same line, ω⊥=(1,0)\omega^\perp = (1, 0) and the length is 0.50.5: the weight is e−0.5=0.6065e^{-0.5} = 0.6065. The two directions of one line give different data. This is why the full circle of angles is needed.

Non-example: PET data. In positron emission tomography the two photons of one event move in opposite directions along the same line, and both must reach the detectors. The product of the two weights is e−Rμ(θ,s)e^{-\mathcal{R}\mu(\theta, s)}, the same for every point of the line. So PET data are e−Rμ Rfe^{-\mathcal{R}\mu}\,\mathcal{R}f: the Radon transform times a known factor, which a transmission scan measures. It is not an attenuated Radon transform in the sense above, and the attenuation correction is a division.

A special case: constant attenuation. If μ=μ0\mu = \mu_0 on a known convex region that holds the support of ff, the weight can be split into a factor that depends only on the line and the factor eμ0te^{\mu_0 t}. After this correction the data are the exponential Radon transform ∫f(sω+tω⊥) eμ0t dt\int f(s\omega + t\omega^\perp)\, e^{\mu_0 t}\,dt. Tretiak and Metz (1980) inverted it with a filtered back projection with a modified filter.

Non-example: a transmission scan. In transmission CT the source is outside the body, and the data are e−Rμe^{-\mathcal{R}\mu} for the attenuation μ\mu itself. Taking the log gives the Radon transform of μ\mu. There is no emission activity ff and no weight inside the integral.

  • Radon transform: the case μ=0\mu = 0.
  • X-ray transform: the line integrals in any dimension; the attenuated X-ray transform adds the same weight.
  • Novikov inversion formula: the explicit inverse of Rμ\mathcal{R}_\mu in the plane for a known μ\mu.
  • Radon inversion formula: the inverse for μ=0\mu = 0, which the Novikov formula reduces to.
  • Hilbert transform: the filter in ss that appears in both inversion formulas.
  • Emission tomography model: the Poisson model for the counts, where a discrete Rμ\mathcal{R}_\mu is the system matrix of SPECT.
  • Sinogram: the data shown as an image over (θ,s)(\theta, s); for SPECT it covers θ∈[0,2π)\theta \in [0, 2\pi).

References

  1. R. G. Novikov, An inversion formula for the attenuated X-ray transformation, Arkiv for Matematik 40(1), 2002, pp. 145 to 167 (the attenuated transform in the plane and its explicit inversion)
  2. F. Natterer, Inversion of the attenuated Radon transform, Inverse Problems 17(1), 2001, pp. 113 to 119 (the definition with the divergent beam transform, and a short derivation of the inversion)
  3. O. Tretiak and C. Metz, The exponential Radon transform, SIAM Journal on Applied Mathematics 39(2), 1980, pp. 341 to 354 (the case of a constant attenuation and its inversion)
  4. F. Natterer and F. Wubbeling, Mathematical Methods in Image Reconstruction, SIAM, 2001, Chapter 2, Integral Geometry, pp. 9 to 40 (the attenuated Radon transform among the integral transforms of tomography; general locator)

Where this leads

About this page

The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.

LadderLevelWhat the next level needs
Human proofH0 no proof
  • add a proof in proofs/ (06.5)
LeanL0 no Lean part
  • name a Lean module in the lean field (07)
VisualV0 none
  • add viz/scene.ts or a figure (10)
WritingW4 complete
  • a review of the text: no review record reviews/KJR2GS/text.yaml