Definitioncore
X-ray transform
Also called ray transform.
The map that takes a function in n dimensions to its integrals along lines, equal to the Radon transform in the plane and different from it in space.
The X-ray transform takes a function on to its integrals along all straight lines. It models X-ray imaging in any dimension, because a ray measures the integral of the attenuation along a line, by the Beer-Lambert law. In the plane the lines are the hyperplanes, so the X-ray transform and the Radon transform are the same thing with a different parametrization. In they differ: the Radon transform integrates over planes and the X-ray transform over lines, and CT scanners measure line integrals.
Definition
Let . For a direction and a point in the hyperplane , the X-ray transform of is
Each line in is for exactly one pair with , and . For a fixed , the function on is the parallel projection, or radiograph, in the direction . By Fubini's theorem , so the integral exists for almost every .
The plane. For , take and with . Then . The X-ray transform names a line by its direction, the Radon transform by its normal.
The divergent beam transform. A point source at gives the integrals along half-lines, . For with support away from , with the projection of on . Fan-beam and cone-beam CT measure for sources on a curve.
Fourier slice relation. With the Fourier transform in ordinary frequency, , the -dimensional transform of the projection on is
The proof is Fubini's theorem: write each as , and note that when . So one radiograph gives on the whole hyperplane , not only on a line as in the 2D Fourier slice theorem. With Natterer's unitary transform the same relation has the factor .
Examples and non-examples
The ball in 3D. Let on the unit ball of . A line at distance from the center cuts a chord of length , so for in each direction. The plane at distance cuts a disk of radius , so the 3D Radon transform is . The two transforms of the same ball are different functions. Both have the right mass: and , the volume of the ball.
The Gaussian in 3D. For , on , a 2D Gaussian, and . Both match through the slice relation above and through the slice theorem for planes.
From lines to planes. Integrating the radiograph along a line in gives the integral of over a plane that contains . So the X-ray transform determines the 3D Radon transform on all planes that contain a measured direction. The Grangeat formula uses a related identity for cone-beam data, where only a derivative of the plane integrals is available.
Enough directions. In the lines form a 4-parameter family and has 3 variables, so not all lines are needed. If the directions fill one great circle, for example all directions with , then each measured line lies in a plane , and the data are the 2D Radon transforms of all these slices. This is slice-by-slice CT, and it determines .
Non-example: the 3D Radon transform. Integrals of over planes are not X-ray data. In 3D they are the data of the Radon inversion formula , which is local, while X-ray data in a plane need the nonlocal 2D formula (Radon inversion formula).
Non-example: a circular cone-beam scan. A source that moves on one circle measures for a set of lines that does not meet the Tuy condition. The data do not determine off the plane of the circle in a stable way, and the Feldkamp-Davis-Kress method is an approximation there. A helical source orbit meets the condition, and the Katsevich algorithm inverts it exactly.
Related definitions
- Radon transform: integrals over hyperplanes. It is the X-ray transform when .
- Back-projection operator: the adjoint, which sums over all measured lines through a point.
- Fourier slice theorem: the 2D form of the slice relation above.
- Attenuated Radon transform: line integrals with an exponential weight along the line.
- Tuy condition: the condition on a source curve under which cone-beam data determine .
References
- D. C. Solmon, The X-ray transform, Journal of Mathematical Analysis and Applications 56(1), 1976, pp. 61 to 83 (the X-ray transform in n dimensions, its Fourier slice relation and its inversion)
- F. Natterer, The Mathematics of Computerized Tomography, SIAM Classics in Applied Mathematics 32, 2001, Section II.1 (the X-ray transform P and the divergent beam transform D next to the Radon transform R)
- K. T. Smith, D. C. Solmon and S. L. Wagner, Practical and mathematical aspects of the problem of reconstructing objects from radiographs, Bulletin of the American Mathematical Society 83(6), 1977, pp. 1227 to 1270 (the X-ray and divergent beam transforms and what finite data determine)
Where this leads
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W4 complete |
|
Tag JVBXZD Edit this page History Report an error Markdown