Definitionintro
Steady-state error
Also called tracking error at steady state.
The limit of the error r - y of a stable loop for a step, ramp or parabola reference. The system type and the constants K_p, K_v and K_a give it, for example 1/(1 + K_p) for a step and type 0.
The steady-state error of a feedback control loop is the limit, as time goes to infinity, of the error between the reference and the output, for a reference of a given shape. The standard shapes are the step, the ramp and the parabola. In a unity feedback loop the answer depends on only two facts about the loop transfer function : its number of poles at , called the system type, and one gain, the error constant. A type 0 loop follows a unit step with the error , a type 1 loop follows it with zero error and a ramp with the error , and so on. The numbers mean something only when the loop is internally stable; the formulas give a finite value for an unstable loop too, and that value is then wrong.
Definition
Take a negative unity feedback loop with , , and a rational loop transfer function . Assume the loop is internally stable. With and the sensitivity function, the steady-state error to the reference is
when the limit exists. If is unbounded, the error is said to be infinite.
System type. Write with and . The integer , the number of poles of at the origin, is the type of the loop.
Error constants.
They are the position, velocity and acceleration error constants. If and have the same unit, has no unit, is in 1/s and in 1/s. For a loop of type , the constant of index equals , the lower ones are infinite and the higher ones are 0.
The table. For the references (step), (ramp) and (parabola), :
| type | step | ramp | parabola |
|---|---|---|---|
| 0 | |||
| 1 | 0 | ||
| 2 | 0 | 0 |
A reference with a different size scales the error: a ramp gives in a type 1 loop.
Why. For , and
The denominator is the characteristic polynomial of the loop up to a constant factor, so it is Hurwitz. If , has all its poles in the open left half plane, and the final value theorem gives : this is 0 for , and for , and for . If , has a pole of order at the origin, so by partial fractions contains a term with and grows without bound. The final value theorem does not apply in that case.
Examples and non-examples
Example: type 0. . Then and the step error is . The closed loop is Hurwitz, so the value is correct. A ramp reference gives an error that grows like .
Example: type 1. . Then 1/s, the step error is 0 and the ramp error is . The closed loop is Hurwitz. This loop is the standard second-order system with and , and indeed .
Example: a disturbance is a different input. Let and , a type 1 loop with zero step error to the reference. A unit step load disturbance at the plant input gives , and
The integrator of the plant does not remove this error, because it is behind the point where the disturbance enters. An integrator in does. The system type counts the poles of , so it only speaks about the reference; the internal model principle gives the rule for a disturbance at any point.
Non-example: an unstable loop. gives and the formula ramp error . But the closed loop is not Hurwitz (for a cubic with positive coefficients, the test is , and ; see the Routh-Hurwitz criterion). The error grows without bound. The value 0.2 is meaningless.
Non-example: a non-unity feedback loop. If the sensor has the transfer function with , the signal the controller sees, , is not the error . The table applies only after the loop is redrawn as a unity feedback loop with the equivalent loop transfer function .
Related definitions
- Sensitivity at zero frequency. For a step, . A type loop has near the origin, which is the frequency-domain form of the table.
- Bode plot reading. For a type 1 loop the low-frequency asymptote of is , which crosses 1 at .
- Discrete time. For a loop with the sampling period , the type is the number of poles at , and , . The discrete final value theorem replaces the continuous one.
- Integral action. An integrator in the controller raises the type by one; this is the reason for the I term of the PID controller and for integral state feedback.
- Internal model principle. Zero steady-state error to a step, a ramp or a sinusoid for all small plant changes needs a copy of the signal model in the controller; see internal model principle.
References
- Gene F. Franklin, J. David Powell and Abbas Emami-Naeini, Feedback Control of Dynamic Systems, eighth edition, Pearson, 2019, Chapter 4, A First Analysis of Feedback (the control of the steady-state error to polynomial inputs, the system type and the error constants)
- Katsuhiko Ogata, Modern Control Engineering, fifth edition, Prentice Hall, 2010, Chapter 5, Transient and Steady-State Response Analyses (steady-state errors in unity feedback systems, the static position, velocity and acceleration error constants)
Where this leads
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W4 complete |
|
Tag W3CB6S Edit this page History Report an error Markdown