Theoremcore
Internal model principle
Also called Francis-Wonham internal model principle.
A stable loop keeps zero steady-state error to a class of references or disturbances under all small plant changes only if the controller contains a model of the generator of that class.
The internal model principle says what a feedback controller must contain to drive the error to zero for a whole class of reference or disturbance signals, and to keep doing so when the plant changes a little. If the signals are steps, the controller needs an integrator. If they are sinusoids of frequency , it needs the poles . In general it needs the unstable modes of the system that generates the signals, the exosystem, and in a loop with outputs it needs copies of them. Francis and Wonham proved the principle in 1975 and 1976 for multivariable linear systems. The key hypothesis is that zero error must hold for all plants near the nominal one, the structural stability of the regulation property. Without it, a controller can reach zero error for one plant only.
Statement
Setup. Consider a negative unity feedback loop with , a strictly proper plant and a proper controller , both written with coprime real polynomials. The loop is internally stable when the characteristic polynomial is Hurwitz. Let be a monic real polynomial with all roots in the closed right half plane. The signal class of is the set of all signals whose Laplace transform is for a real polynomial with : the outputs of the exosystem with characteristic polynomial , for all its initial states. For example, gives the constants, the ramps , and the sinusoids of frequency .
Theorem (single output). Let the loop be internally stable.
- (Regulation.) for every reference in the signal class of if and only if divides .
- (Robust regulation.) The following are equivalent:
- (a) there is a neighborhood of the plant coefficients (with the degrees of and fixed) such that, for every plant in it, the loop with the same is internally stable and for every in the class of ;
- (b) divides : the controller has every root of as a pole, with at least the same multiplicity.
The same holds for a disturbance at the plant output, because and use the same .
Theorem (Francis and Wonham 1976, multivariable form, informal). Let a linear plant with inputs and regulated outputs be driven by an exosystem whose eigenvalues are all in the closed right half plane, and let the controller be driven by the error. Suppose the closed loop is internally stable and the error goes to 0 for every initial state of the plant, the controller and the exosystem. Then this regulation property holds for all plant data in a neighborhood of the nominal data if and only if the controller contains a -fold copy of the exosystem dynamics: in a precise sense stated in the paper, copies of the minimal polynomial of appear in the controller. For and a transfer function controller this is part 2 above. A common sufficient form is , the series connection of exosystem models with a stabilizer .
Existence (Davison 1976, in short). For a plant , with error , a controller with this property exists if and only if is stabilizable, is detectable, and at every root of . The rank condition says that the plant has no transmission zero at a mode of the exosystem, and it needs .
In plain words
To cancel a disturbance that keeps coming back in the same pattern, the controller must be able to make that pattern by itself. A heater that must hold a room at a set temperature against a steady heat loss needs a part that adds up the error over time, so it can keep giving heat when the error is zero. A controller that must cancel a hum at one frequency needs a part that oscillates at that frequency. You can sometimes tune a controller without such a part so that it works for one exact plant. But the first small change in the plant then brings the error back. Only a copy of the signal pattern inside the controller gives zero error that survives small plant changes, and a system with several outputs needs one copy for each output.
Proof
The proof is for the single-output theorem. It uses the final value theorem in its exact form for rational transforms, including its Lemma A: an exponential polynomial over exponents with goes to 0 only if all are zero.
Part 1. For ,
If. Let . Then . Since is strictly proper and is proper, , so and is strictly proper. Its poles are roots of the Hurwitz , so .
Only if. Suppose does not divide . Then some root of has a larger multiplicity in than its multiplicity in . Take , which is allowed since . Because and is Hurwitz, , so after all cancellations still has a pole of order at . Then is an exponential polynomial whose part with exponents in the closed right half plane is not zero, and by Lemma A it does not go to 0.
Part 2, (b) implies (a). Let . The roots of depend continuously on the coefficients of and , and the degree of stays the same near , because its leading coefficient is that of . So stays Hurwitz in a neighborhood of the plant, and coprimeness of and also persists there, because the resultant of and is nonzero and depends continuously on the coefficients. For each such plant , so Part 1 gives .
Part 2, (a) implies (b). Suppose does not divide , and let be a root of whose multiplicity in is larger than its multiplicity in . Perturb only the constant term of the plant denominator: and . Then is nonzero for all , so for all small the multiplicity of in is exactly , and does not divide . If (a) held, these plants would be in the neighborhood, the loop would be internally stable for them, and Part 1 would give an in the class with . So (a) fails.
The multivariable theorem needs the geometric approach of Francis and Wonham, or the frequency-domain arguments in the later literature; the proof is in the 1976 paper. The idea is the same: a mode of the exosystem that is not a pole of the controller must be cancelled by the plant, and a small perturbation of the plant breaks the cancellation.
Consequences
- Integral action. For steps (), robust zero error needs a pole of at . This is the reason for the I term of the PID controller and for integral state feedback. For ramps a double integrator is needed. The table of the steady-state error page is Part 1 for .
- The point of entry does not matter. The internal model must be in the controller, not only somewhere in the loop. A plant integrator rejects a step reference, but not a step disturbance at the plant input (the example on the steady-state error page).
- Sinusoids. A resonant term in rejects a sinusoidal disturbance of frequency for all small plant changes. Periodic signals with many harmonics need many such terms, which leads to repetitive control.
- Multivariable plants. A plant with outputs needs copies, for example integrators for constant references, and at least as many inputs as outputs (Davison's rank condition).
- State-space regulation. The output regulation problem asks for the same property in state space; its solvability is decided by the regulator equations, and the controllers that solve it robustly contain the internal model. Disturbance observers and offset-free MPC build the model into an estimator.
- Not internal model control. Internal model control is a controller structure that contains a model of the plant, not of the signals. The two names are close and the ideas are different.
Tightness
Regulation without robustness. Let and . The loop has , and divides , so the step error is 0 by Part 1. But . Perturb the plant to : the step error becomes , for example 0.0476 for . If the physics guarantees that the plant pole stays exactly at 0 (an angle that is the integral of a speed), the perturbation class is smaller, and a smaller internal model is enough. The theorem is relative to the class of perturbations.
The model must be exact. Let and (). The controller gives and , so and the error goes to 0. For the changed plant , is still Hurwitz () and the error still goes to 0. If the controller denominator is instead, the error amplitude is , small but not zero. A proportional controller leaves .
Robustness is local. Part 2 promises zero error only in a neighborhood where the loop stays internally stable. A large plant change can destabilize the loop, and then the internal model does not help.
Internal stability is needed. Without it, some closed-loop map has poles in the closed right half plane. A controller zero that cancels an unstable plant pole can give an with zero error to the reference while a load disturbance makes an internal signal grow without bound.
History
Integral action was used in governors and process controllers long before a general theory. In the early 1970s several groups studied the servomechanism and regulator problems for multivariable linear systems. Francis and Wonham presented the internal model principle at an IFAC symposium in 1975 and published it in Automatica in 1976, in the language of the geometric approach. Davison (1976) solved the robust servomechanism problem and gave the existence conditions above. Francis (1977) treated the linear multivariable regulator problem with internal stability. The principle was later extended to nonlinear systems in the theory of output regulation.
References
- B. A. Francis and W. M. Wonham, The internal model principle of control theory, Automatica 12(5) (1976) 457-465, the whole paper (structurally stable regulation and the internal model in the controller)
- E. J. Davison, The robust control of a servomechanism problem for linear time-invariant multivariable systems, IEEE Transactions on Automatic Control 21(1) (1976) 25-34, the whole paper (existence conditions and the structure of a robust servo controller)
- B. A. Francis, The linear multivariable regulator problem, SIAM Journal on Control and Optimization 15(3) (1977) 486-505, the whole paper (the regulator problem with internal stability, and its solution by the regulator equations)
Where this leads
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W4 complete |
|
Tag B93JKJ Edit this page History Report an error Markdown