Modelintro
Standard second-order system
Also called damped harmonic oscillator model.
The transfer function omega_n^2 / (s^2 + 2 zeta omega_n s + omega_n^2). The damping ratio zeta and the natural frequency omega_n fix the overshoot, the speed and the resonance in closed form.
The standard second-order system is the linear model with the transfer function
with the natural frequency in rad/s and the dimensionless damping ratio . It is the damped harmonic oscillator with unit static gain: a mass on a spring with a damper, or a series RLC circuit. Two numbers fix all of its behavior, and the overshoot, the peak time, the resonant peak and the bandwidth have exact formulas in and . That is why closed-loop specifications are often stated as a target pair of poles , and why a higher-order loop is often read through a "dominant" second-order pair. That reading is an approximation, and this page says when it fails.
The machine
Equations. The input and the output are real, and time is continuous, in seconds. The model is the linear ordinary differential equation
With zero initial conditions and the one-sided Laplace transform, . A state-space representation with the state is
This realization is minimal, so the poles of are the eigenvalues of the matrix.
Physical forms. A mass (kg) on a spring of stiffness (N/m) with a damper (N s/m), driven by the force , obeys . So and . A series RLC circuit with the output at the capacitor has and .
Poles. The poles are . There are four cases:
| case | poles | |
|---|---|---|
| undamped | ||
| underdamped | , with and | |
| critically damped | , twice | |
| overdamped | two distinct negative real poles with |
In the underdamped case the poles lie on the circle of radius , at the angle from the negative real axis. So fixes the angle of the poles and their distance from the origin. For the poles are in the right half plane and the system is unstable; the formulas below assume unless they say otherwise.
What it counts
The model predicts the whole response to any input from the two parameters. The usual uses are:
- Step response numbers. The overshoot, the peak time, the rise time and the settling time of the step response specifications, as exact functions or bounds in and .
- Frequency response numbers. The resonant peak, the resonant frequency and the bandwidth.
- Parameter fits. From a measured step response with overshoot and peak time , the inverse formulas give and . With and s they return and rad/s. The fit is exact only if the plant is of this form; on a real plant it is a measurement with an error.
Relation to other models
- First-order system : the limit of an overdamped second-order system when one pole is much faster than the other. It never overshoots.
- Higher-order systems with a dominant pair. If a linear time-invariant system has a pair of complex poles much closer to the imaginary axis than all other poles and zeros, its step response is close to that of the pair with the same static gain. This is a design approximation, not a theorem with a stated error. It fails when a zero is near the pair (a zero at adds the term and raises the overshoot), when a third pole is not far away (it slows the response and lowers the overshoot), and when a pole and a zero nearly cancel (they leave a slow tail). A ratio of 5 to 10 between the real parts is a common rule of thumb.
- Second-order system with a zero. ; for the zero is in the right half plane and the step response starts in the wrong direction.
- Discrete time. Sampling with a zero-order hold and the period maps the poles to ; see zero-order-hold discretization.
- As a closed loop. The loop transfer function in a unity feedback loop gives the closed loop . So the model is also the closed loop of a type 1 plant with a proportional controller; see complementary sensitivity function.
Known results in the model
All results below are exact for the model, and each one follows from the formula for in a few lines.
Step response. For a unit step input and zero initial state,
- underdamped: , with ;
- undamped: ;
- critically damped: ;
- overdamped: .
Each follows from the partial fraction decomposition of . The impulse response is the derivative; in the underdamped case it is .
Peak time and overshoot (). The derivative is zero at , , and the largest value is at , where and . So
For and : s and . For there is no overshoot. The overshoot depends on only.
Rise time. The first time is , the 0 to 100 percent rise time; for , it is 2.4184 s. The 10 to 90 percent rise time has no closed form; for , it is 1.6376 s. The formula is a rule of thumb, tuned near .
Settling time. The response stays inside the envelope . So the response is inside the band for all with
which is an upper bound on the true settling time. For , and , the bound is 8.1117 s and the true 2 percent settling time is 8.0763 s. The common formula drops the factor and rounds to 4; it gives 8 s here and is a rule of thumb. For the 5 percent band, the true value is 5.2891 s and the rule gives 6 s.
Frequency response. With ,
The phase is degrees at for every . Minimizing the denominator over gives:
- Resonance. For , the peak is at . For , decreases from 1 and there is no resonance. For : at . For : .
- Bandwidth. at ; for , .
System norms. The H-infinity norm is for and 1 otherwise. The H2 norm satisfies for . For , , that is , the norms are 5.02519 and .
As a unity feedback loop. For , at , and the phase margin is . For it is 51.83 degrees. The rule degrees for is a fit to this formula, not an identity. The velocity error constant is (in 1/s), so a ramp is followed with the steady-state error .
Design regions. A bound is the same as , a sector around the negative real axis; a bound on the 0 to 100 percent rise time or on bounds ; the settling bound bounds from below. These regions in the plane are what the root locus method aims at. For a loop of higher order they are targets for the dominant pair, with the caveats above.
References
- Gene F. Franklin, J. David Powell and Abbas Emami-Naeini, Feedback Control of Dynamic Systems, eighth edition, Pearson, 2019, Chapter 3, Dynamic Response (the poles of a second-order system, the time-domain specifications, and the effects of zeros and extra poles)
- Katsuhiko Ogata, Modern Control Engineering, fifth edition, Prentice Hall, 2010, Chapter 5, Transient and Steady-State Response Analyses (second-order systems and their step response specifications), and Chapter 7 (the resonant peak and frequency of the second-order system)
- Karl J. Åström and Richard M. Murray, Feedback Systems, An Introduction for Scientists and Engineers, second edition, Princeton University Press, 2021, Chapter 6, Linear Systems (the step response and its specifications), and Chapter 7, State Feedback (second-order systems and the damping ratio)
Where this leads
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W4 complete |
|
Tag R10NPS Edit this page History Report an error Markdown