Definitioncore
Complementary sensitivity function
Also called complementary sensitivity.
T = L/(1 + L), the closed-loop map from reference to output and from sensor noise to output, with S + T = 1. A small peak of W T gives robust stability under multiplicative plant errors.
The complementary sensitivity function of a feedback control loop is the transfer function , where is the loop transfer function. In a unity feedback loop it is the closed-loop map from the reference to the output , and, with a minus sign, the map from the sensor noise to . Its name comes from the identity with the sensitivity function . So the two cannot both be small at one frequency: a loop that rejects disturbances (small ) at a frequency passes the sensor noise (with near 1) at that frequency. The size of also decides how large a relative plant error the loop can tolerate before it loses stability.
Definition
Let and be real rational transfer functions in a negative unity feedback loop that is well posed, . The complementary sensitivity function is
With and in coprime form, . Its denominator is the characteristic polynomial of the loop, and its zeros are the zeros of .
Readings. With and :
So is the response of the output to the reference and to the noise, with opposite signs. A noise that the loop cannot tell apart from the output gets the same treatment as a reference.
Peak. For an internally stable loop, . A large means a resonant closed loop. Bounds on the margins follow from the definitions. At a phase crossover, , so . At a gain crossover, and , so . Hence, for ,
Robust stability under multiplicative uncertainty. Let the true plant be , where the weight is a stable transfer function and is any stable transfer function with (the H-infinity norm). Assume the nominal loop with is internally stable and that each has the same number of poles in the closed right half plane as . Then the loop is internally stable for every such if and only if
This is a theorem (Doyle, Francis and Tannenbaum 1992, chapter 4; Skogestad and Postlethwaite, chapter 7). The idea of the sufficiency part: by the assumption, the open-loop pole count of the Nyquist criterion is the same for and , and on the Nyquist contour , so as is scaled from 0 to its full size, the Nyquist curve of never reaches , and the count of encirclements of the Nyquist stability criterion does not change. The necessity part builds a of norm at most 1 that puts a closed-loop pole on the imaginary axis at a frequency where . The test is the small-gain theorem applied to the loop seen by , whose gain is ; see model uncertainty.
Examples and non-examples
Example: a third-order loop. Let , which gives an internally stable loop. Then
- , because has a pole at 0: a constant reference is followed exactly in steady state.
- The peak is at rad/s, and at rad/s, the closed-loop bandwidth.
- At rad/s, and . At rad/s, : fast noise hardly reaches the output.
- The bounds give and degrees. The true values are and degrees. The phase margin bound is almost tight because the peak of is close to the gain crossover rad/s.
- With a constant weight (a relative plant error of up to 50 percent at every frequency), , so the loop stays internally stable for all such errors. The largest constant weight the test allows is .
Example: the trade at one frequency. From and the triangle inequality, at each . So at every frequency. A loop cannot reject a disturbance and a sensor noise in the same frequency band.
Example: a right half plane zero. If has a zero at with , then every internally stable loop has and . For a real zero and a loop with integral action, and for the unit step response . Since , the step response must be negative for some : it starts in the wrong direction. For example, has , and every internally stable loop with integral action around it shows this undershoot.
Non-example: of an unstable loop. For the closed loop has two poles in the right half plane, and is not a gain from a sinusoidal reference to the output.
Non-example: is not the only transfer function to check. For and , is stable, but the loop is not internally stable, because has a pole at . A stable alone does not prove internal stability.
Related definitions
- Sensitivity function , the map from an output disturbance to the output.
- Multivariable loops. The output complementary sensitivity is and the input one is , with and .
- Closed-loop bandwidth. The frequency where first drops to of . For the standard second-order system, is the whole closed loop, and its bandwidth has a closed form.
- Weighted complementary sensitivity. The term in mixed sensitivity design and the high-frequency part of loop shaping.
References
- Karl J. Åström and Richard M. Murray, Feedback Systems, An Introduction for Scientists and Engineers, second edition, Princeton University Press, 2021, Chapter 12, Frequency Domain Design (the section Sensitivity Functions), and Chapter 13, Robust Performance (the section Stability in the Presence of Uncertainty, the condition on the complementary sensitivity)
- Sigurd Skogestad and Ian Postlethwaite, Multivariable Feedback Control, Analysis and Design, second edition, Wiley, 2005, Chapter 2, Classical Feedback Control (S, T, the peaks M_S and M_T and the bounds on the margins), and Chapter 7, Uncertainty and Robustness for SISO Systems (robust stability with multiplicative uncertainty)
- John C. Doyle, Bruce A. Francis and Allen R. Tannenbaum, Feedback Control Theory, Macmillan, 1992, Chapter 4, Uncertainty and Robustness (robust stability for multiplicative perturbations)
Where this leads
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W4 complete |
|
Tag 0WHXZ1 Edit this page History Report an error Markdown