Sensitivity function

Also called sensitivity transfer function.

S = 1/(1 + L) for the loop transfer function L. It maps an output disturbance to the output, gives the relative change of the loop per change of the plant, and its peak is 1 over the distance to -1.

The sensitivity function of a feedback control loop is the transfer function S(s)=1/(1+L(s))S(s) = 1/(1 + L(s)), where L=PCL = P C is the loop transfer function of the plant PP and the controller CC. It has three readings that are the same formula: it is the transfer function from a disturbance at the plant output to the output, it is the transfer function from the reference to the error e=r−ye = r - y, and it is the relative change of the closed loop per relative change of the plant. Feedback helps where ∣S(jω)∣<1|S(j\omega)| < 1 and hurts where ∣S(jω)∣>1|S(j\omega)| > 1. Its largest value MsM_s is the inverse of the distance from the Nyquist curve of LL to the critical point −1-1, which makes it a better single measure of robustness than the gain margin or the phase margin.

Definition

Let P(s)P(s) and C(s)C(s) be real rational transfer functions, with negative unity feedback, and let the loop be well posed, that is 1+L(∞)≠01 + L(\infty) \ne 0. The sensitivity function is

S(s)=11+L(s)=11+P(s) C(s).S(s) = \frac{1}{1 + L(s)} = \frac{1}{1 + P(s)\,C(s)}.

With P=b/aP = b/a and C=nc/dcC = n_c/d_c as ratios of coprime polynomials, S=a dc/(a dc+b nc)S = a\,d_c / (a\,d_c + b\,n_c). Its poles are among the closed-loop poles, and its zeros include the poles of LL.

Three readings.

  1. Output disturbance. If y=Pu+doy = P u + d_o and u=C(r−y)u = C (r - y), then y=Tr+Sdoy = T r + S d_o, with T=L/(1+L)T = L/(1 + L) the complementary sensitivity function.
  2. Tracking error. With do=0d_o = 0, e=r−y=Sre = r - y = S r.
  3. Relative sensitivity. For the closed-loop map T=PC/(1+PC)T = P C/(1 + P C), a change dPdP of the plant gives
dTdP=C(1+PC)2,dT/TdP/P=dTdP⋅PT=C(1+PC)2⋅(1+PC)⋅1C=S.\frac{dT}{dP} = \frac{C}{(1 + P C)^2}, \qquad \frac{dT/T}{dP/P} = \frac{dT}{dP} \cdot \frac{P}{T} = \frac{C}{(1 + PC)^2} \cdot (1 + PC) \cdot \frac{1}{C} = S.

So SS is the ratio of the relative change of the closed loop to the relative change of the plant, for small changes. Some older texts use the inverse ratio, the return difference 1+L1 + L, under the same name; check the convention of a source before you use its formulas.

Peak sensitivity. For an internally stable loop, the peak sensitivity is the H-infinity norm of SS,

Ms=∥S∥∞=sup⁡ω≥0∣S(jω)∣=1inf⁡ω∣1+L(jω)∣=1sm,M_s = \|S\|_\infty = \sup_{\omega \ge 0} |S(j\omega)| = \frac{1}{\inf_{\omega} |1 + L(j\omega)|} = \frac{1}{s_m},

where sm=inf⁡ω∣L(jω)−(−1)∣s_m = \inf_\omega |L(j\omega) - (-1)| is the smallest distance from the Nyquist curve of LL to −1-1, the stability margin or vector margin. Usual designs have MsM_s between 1.2 and 2; this is a design rule of thumb from practice (Åström and Murray; Skogestad and Postlethwaite, chapter 2), not a theorem.

Bounds on the classical margins. Let MsM_s be finite. If L(jωpc)=−1/gmL(j\omega_{pc}) = -1/g_m at a phase crossover, the distance to −1-1 there is ∣1−1/gm∣≥1/Ms|1 - 1/g_m| \ge 1/M_s. If ∣L(jωc)∣=1|L(j\omega_c)| = 1 at a gain crossover with phase margin φm\varphi_m, then ∣1+L(jωc)∣=2sin⁡(φm/2)≥1/Ms|1 + L(j\omega_c)| = 2 \sin(\varphi_m/2) \ge 1/M_s. So, for gm>1g_m > 1,

gm≥MsMs−1,φm≥2arcsin⁡12Ms.g_m \ge \frac{M_s}{M_s - 1}, \qquad \varphi_m \ge 2 \arcsin \frac{1}{2 M_s}.

The converse fails: good gain and phase margins do not bound MsM_s, because the Nyquist curve can pass near −1-1 at a frequency that is neither crossover.

Multivariable loops. For a plant with mm inputs and pp outputs, the output sensitivity is So=(I+PC)−1S_o = (I + P C)^{-1}, a p×pp \times p matrix, and the input sensitivity is Si=(I+CP)−1S_i = (I + C P)^{-1}, an m×mm \times m matrix. They differ when PC≠CPP C \ne C P, which is the usual case. They are related by PSi=SoPP S_i = S_o P. The disturbance at the plant output sees SoS_o; a disturbance at the plant input sees PSiP S_i.

Examples and non-examples

Example: a third-order loop. Let L(s)=1/(s(s+1)(s+2))L(s) = 1/(s (s + 1)(s + 2)). The closed loop s3+3s2+2s+1s^3 + 3 s^2 + 2 s + 1 has its roots at −2.3247-2.3247 and −0.3376±0.5623j-0.3376 \pm 0.5623 j, so the loop is internally stable. Values of ∣S(jω)∣|S(j\omega)|:

ω\omega (rad/s) 0.01 0.1 0.7263 1 10
∣S(jω)∣\lvert S(j\omega) \rvert 0.0200 0.2032 1.5684 (peak) 1.4142 1.0003

At low frequency L(s)≈1/(2s)L(s) \approx 1/(2 s), so ∣S(jω)∣≈2ω|S(j\omega)| \approx 2\omega: a slow disturbance is reduced by a large factor. The peak is Ms=1.5684M_s = 1.5684 at ω=0.7263\omega = 0.7263 rad/s, so the Nyquist curve passes at the distance 1/Ms=0.63761/M_s = 0.6376 from −1-1. The bounds give gm≥2.759g_m \ge 2.759 and φm≥37.18\varphi_m \ge 37.18 degrees. The true margins are gm=6g_m = 6 (15.563 dB, at ω=2\omega = \sqrt 2) and φm=53.41\varphi_m = 53.41 degrees (at ωc=0.44575\omega_c = 0.44575 rad/s), so the bounds hold and are not tight here. With D(s)=s(s+1)(s+2)D(s) = s(s + 1)(s + 2), ∣S∣2=∣D∣2/∣D+1∣2|S|^2 = |D|^2 / |D + 1|^2, and ∣D+1∣2−∣D∣2=1+2Re⁡D(jω)=1−6ω2|D + 1|^2 - |D|^2 = 1 + 2 \operatorname{Re} D(j\omega) = 1 - 6\omega^2. So ∣S(jω)∣>1|S(j\omega)| > 1 exactly for ω>1/6=0.4082\omega > 1/\sqrt 6 = 0.4082 rad/s: disturbances at those frequencies are amplified by the loop.

Example: the plant change in Black's amplifier. With A=105A = 10^5 and β=0.01\beta = 0.01, L=Aβ=1000L = A\beta = 1000 and S=1/1001S = 1/1001. A 1 percent change of AA changes the closed-loop gain by about 0.0010.001 percent.

Example: integral action. If LL has a pole at s=0s = 0, then S(0)=0S(0) = 0, and an internally stable loop rejects a constant output disturbance fully. This is the simplest case of the internal model principle.

Non-example: an unstable loop. For L(s)=10/(s(s+1)(s+2))L(s) = 10/(s (s + 1)(s + 2)), S(s)=s(s+1)(s+2)/(s3+3s2+2s+10)S(s) = s(s + 1)(s + 2)/(s^3 + 3s^2 + 2 s + 10) has two poles in the right half plane. The function ∣S(jω)∣|S(j\omega)| can still be plotted, but it is not the gain from a sinusoidal disturbance to the output, because the response grows without bound. The readings above need an internally stable loop.

Non-example: the open-loop sensitivity. Without feedback, y=PCry = P C r, and the relative change of the map is the relative change of PP: the sensitivity is 1 at all frequencies. Only feedback can make it smaller.

  • Complementary sensitivity T=L/(1+L)T = L/(1 + L), with S+T=1S + T = 1. See complementary sensitivity function.
  • Return difference 1+L1 + L, the quantity Bode used; SS is its inverse.
  • Interpolation constraints. For an internally stable loop, S(p)=0S(p) = 0 at each pole pp of LL in the closed right half plane, and S(z)=1S(z) = 1 at each zero zz of PP in the closed right half plane. These limit what a design can do.
  • Bode sensitivity integral. For LL of relative degree at least 2 and an internally stable loop, ∫0∞ln⁡∣S(jω)∣ dω=π∑kRe⁡pk\int_0^\infty \ln |S(j\omega)|\, d\omega = \pi \sum_k \operatorname{Re} p_k, summed over the open-loop poles pkp_k in the open right half plane. Making ∣S∣|S| small in one band makes it large in another. See Bode sensitivity integral.
  • Weighted sensitivity. The design condition ∥W1S∥∞<1\|W_1 S\|_\infty < 1 for a weight W1W_1 is the performance part of mixed sensitivity design and of loop shaping.
  • The Nyquist stability criterion decides internal stability from the same curve L(jω)L(j\omega) whose distance to −1-1 gives MsM_s.

References

  1. Karl J. Åström and Richard M. Murray, Feedback Systems, An Introduction for Scientists and Engineers, second edition, Princeton University Press, 2021, Chapter 10, Frequency Domain Analysis (stability margins, with the shortest distance s_m from the Nyquist curve to -1), and Chapter 12, Frequency Domain Design (the section Sensitivity Functions)
  2. Sigurd Skogestad and Ian Postlethwaite, Multivariable Feedback Control, Analysis and Design, second edition, Wiley, 2005, Chapter 2, Classical Feedback Control (the closed-loop transfer functions, the peaks M_S and M_T and their bounds on the margins), and Chapter 3 for the input and output sensitivity of multivariable loops
  3. Hendrik W. Bode, Network Analysis and Feedback Amplifier Design, Van Nostrand, 1945, the chapters on feedback and sensitivity (the return difference and the sensitivity of an amplifier to a change of one element)
  4. Gene F. Franklin, J. David Powell and Abbas Emami-Naeini, Feedback Control of Dynamic Systems, eighth edition, Pearson, 2019, Chapter 4, A First Analysis of Feedback (sensitivity of the closed loop to plant changes) and Chapter 6, The Frequency-Response Design Method

Where this leads

About this page

The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.

LadderLevelWhat the next level needs
Human proofH0 no proof
  • add a proof in proofs/ (06.5)
LeanL0 no Lean part
  • name a Lean module in the lean field (07)
VisualV0 none
  • add viz/scene.ts or a figure (10)
WritingW4 complete
  • a review of the text: no review record reviews/BX9KY0/text.yaml