Definitionintro
Gain margin
Also called gain margin of a feedback loop.
The factor 1/|L(j omega_pc)| by which the loop gain can grow before the closed loop loses asymptotic stability, read where the phase is -180 degrees. With several crossings, the least above 1 counts.
The gain margin of a feedback loop is the factor by which the loop gain can be multiplied before the closed loop loses asymptotic stability. For a loop transfer function whose closed loop is asymptotically stable, it is read at a phase crossover frequency , where the phase of is degrees: there the Nyquist plot crosses the negative real axis at , and the gain margin is , or in dB. If there are several crossings, the margin is the smallest factor greater than 1 among them, or if there is none. A common target is (6 dB), but the gain margin is a heuristic: a loop can have a large gain margin and still come close to at another frequency.
Definition
Notation. The loop is the negative feedback loop of the feedback control loop page with loop transfer function , real rational and proper, and the closed loop is asymptotically stable. The critical point is , frequencies are in rad/s, and gains in dB are of the factor.
Phase crossover. A phase crossover frequency is an where is a negative real number, that is, degrees modulo 360 degrees. On the Bode plot it is where the phase curve crosses , , and so on. On the Nyquist plot it is where the curve crosses the negative real axis.
Definition. Multiply the loop by a real gain . The closed loop of has a pole on the imaginary axis exactly when for some , that is, when lies on the Nyquist plot of . By the Nyquist stability criterion, the number of unstable closed-loop poles of changes only at these values of . Let be the points where the plot of crosses the negative real axis. Then:
- the upper gain margin is , the smallest factor greater than 1, or if there is no crossing between and 0;
- the lower gain margin is , the largest factor less than 1, or 0 if there is no crossing to the left of .
The closed loop of is asymptotically stable for all with . "The gain margin" without a qualifier is . When the loop is unstable by itself or is conditionally stable, and both numbers must be given.
The bound from the peak sensitivity. Let be the peak of the sensitivity function . The Nyquist plot stays at a distance at least from . A crossing between and 0 is therefore at most in size, and
So guarantees , and guarantees . The converse is false: a large does not bound . Values of between 2 and 5 are common targets (Åström and Murray), and is often asked to be between 1.2 and 2.
Examples and non-examples
The check loop. For , the product gives . The phase crossover is , and the gain margin is , or dB. With the gain 6, the closed-loop polynomial is : the poles sit on the imaginary axis at the phase crossover frequency, as the definition says. With the gain 10, the poles are and , and the closed loop is unstable. The peak sensitivity of is , and the bound is well below the true margin 6.
Three equal poles. For , the phase is degrees at . Since , and . So (8.519 dB). The gain at which the loop of reaches the stability limit is 8, the ultimate gain used by Ziegler-Nichols tuning.
An unstable loop has a lower margin. For , the only crossing of the negative real axis is , at . So and : the closed loop is asymptotically stable exactly for . The gain can grow without limit but can drop only by a factor of 2 (6.02 dB).
A conditionally stable loop. For , the plot crosses the negative real axis at (at ) and at (at ). Both are to the left of , so and , or dB. Reading only the first crossing, , would give a false lower margin: the loop is unstable for every between and .
A large margin that says little. The loop is from the section on stability margins in Åström and Murray. Its imaginary part is negative at every , so the Nyquist plot never crosses the negative real axis and . Its phase margin is 69.77 degrees, also large. But the lightly damped pole pair near pulls the curve close to : at , so the curve comes within of the critical point. A small change of the plant near that frequency, not a change of gain, makes this loop unstable.
Related definitions
- The phase margin is the other classical margin, read where . Together with the gain margin it gives two points of the Nyquist plot; gives its smallest distance to .
- The Nichols chart shows the gain margin as the vertical distance below the point (-180 degrees, 0 dB).
- A root locus crosses the imaginary axis at the gain and the frequency .
- Relay autotuning measures the phase crossover frequency and the gain there by an experiment, and Ziegler-Nichols tuning uses them.
- The continuous-time LQR loop has the gain margin interval per channel; see LQR stability margins.
References
- Karl Johan Åström and Richard M. Murray, Feedback Systems, An Introduction for Scientists and Engineers, second edition, Princeton University Press, 2021, Section 10.3, Stability Margins (the gain margin, the stability margin s_m = 1/M_s, and the bounds of the margins in terms of s_m)
- Gene F. Franklin, J. David Powell and Abbas Emami-Naeini, Feedback Control of Dynamic Systems, eighth edition, Pearson, 2019, Section 6.4, Stability Margins
- Sigurd Skogestad and Ian Postlethwaite, Multivariable Feedback Control, Analysis and Design, second edition, Wiley, 2005, Section 2.4.3, Frequency domain performance (gain and phase margins, and the maximum peak criteria)
- Hendrik W. Bode, Network Analysis and Feedback Amplifier Design, Van Nostrand, 1945, the chapters on feedback amplifier design (the margins in gain and phase that a practical amplifier needs); no chapter locator confirmed
Where this leads