Definitioncore
Nichols chart
Also called Nichols plot.
A plot of the open-loop gain in dB against the open-loop phase in degrees, on a grid of contours of constant closed-loop gain and phase of T = L/(1 + L). Used to read margins and shape loops.
A Nichols chart is a plot of the open-loop gain in dB against the open-loop phase in degrees, with the frequency as a parameter along the curve, drawn on a fixed grid of contours of constant closed-loop gain and phase of . One curve then shows the gain margin, the phase margin, the closed-loop resonant peak and the closed-loop bandwidth. A change of the loop gain moves the curve up or down without a change of shape, and a pure phase shift moves it left or right, which makes the chart a good sheet for loop shaping by hand. Nathaniel Nichols and his co-workers introduced it in the 1947 Radiation Laboratory volume Theory of Servomechanisms.
Definition
Notation. The loop is the negative feedback loop of the feedback control loop page with unity feedback, loop transfer function , and complementary sensitivity function , the transfer function from the reference to the output . Phase is in degrees and gain in dB.
The Nichols plot. The Nichols plot of is the curve
with phase on the horizontal axis and gain on the vertical axis. The phase is the continuous branch, as on the Bode plot. The curve carries the same data as the two Bode curves, with the frequency moved from an axis to marks along the curve.
The grid. A point of the plane stands for the complex number . The M-contours are the level sets of , and the N-contours are the level sets of . The grid repeats every 360 degrees of phase and is symmetric about the line degrees. All N-contours pass through the critical point , which stands for . The M-contours for are closed curves around it, and they shrink to it as .
A few contours can be found by hand. means , that is, , so the 0 dB M-contour is for degrees. On the line , where with , , so the contour passes through below the critical point and, for , through above it.
| contour | 0 dB | 1 dB | 3 dB | 6 dB |
|---|---|---|---|---|
| open-loop gain below the critical point, at degrees | -6.02 dB | -5.54 dB | -4.65 dB | -3.53 dB |
Reading the chart.
- The gain margin is the distance in dB from the critical point down to where the curve crosses the line degrees.
- The phase margin is the distance in degrees from the critical point to the right, to where the curve crosses the 0 dB line.
- The closed-loop resonant peak is the value of the highest M-contour that the curve touches.
- The closed-loop bandwidth is the frequency where the curve crosses the dB M-contour.
- The sensitivity function is not on the standard grid, but , and is the point reflection of through the critical point. So the contours of are the M-contours reflected through the critical point.
Examples and non-examples
The check loop. For , the Bode values give these points of the Nichols plot:
| (rad/s) | phase (degrees) | gain (dB) |
|---|---|---|
| 0.1 | -98.57 | 13.925 |
| 0.2 | -107.02 | 7.745 |
| 0.44575 | -126.59 | 0 |
| 1 | -161.57 | -10.000 |
| 1.41421 | -180.00 | -15.563 |
| 2 | -198.43 | -22.041 |
The curve crosses the 0 dB line 53.41 degrees to the right of the critical point (the phase margin) and the degree line 15.563 dB below it (the gain margin). It touches the M-contour of (0.929 dB) at : the closed loop has a small resonant peak. It crosses the dB M-contour at , at the point , so the closed-loop bandwidth is about 0.8 rad/s. Multiplying by 6 moves the whole curve up by 15.563 dB, and then it passes through the critical point; the closed loop has poles at .
You can check one closed-loop value by hand. At , and , so ( dB). The phase of is degrees. This is the M-contour and the N-contour through the point .
Not a Nichols chart. The Nyquist plot shows the same values in the complex plane, where the M-contours are circles, but a gain change scales the curve instead of shifting it. A Bode plot of shows the closed-loop gain directly, but it hides how a change of moves it. A Nichols plot with the phase folded into degrees breaks the curve at degrees, the line where the gain margin is read. The grid assumes unity feedback: with a sensor in the feedback path the contours give with , which is the transfer function from to , not to .
What the chart does not show. The chart does not count encirclements of the critical point, so it does not by itself show that the closed loop is asymptotically stable; that comes from the Nyquist stability criterion. A loop that is unstable by itself can have a curve that looks safe on the chart.
Related definitions
- The Bode plot, the Nyquist plot and the Nichols chart show the same frequency response in three ways.
- The resonant peak relates to the overshoot of the step response; for the second-order system the relation is exact.
- Loop shaping and the lead-lag compensator are often done on the chart, because a lead network moves the curve to the right near crossover and a gain moves it up or down.
References
- Hubert M. James, Nathaniel B. Nichols and Ralph S. Phillips (editors), Theory of Servomechanisms, MIT Radiation Laboratory Series, volume 25, McGraw-Hill, 1947, Chapter 4, General Design Principles for Servomechanisms, by Nichols with Manger and Krohn (the plot of the loop gain in decibels against phase, with loci of constant closed-loop gain)
- Gene F. Franklin, J. David Powell and Abbas Emami-Naeini, Feedback Control of Dynamic Systems, eighth edition, Pearson, 2019, Section 6.9.1, Nichols Chart
- Katsuhiko Ogata, Modern Control Engineering, fifth edition, Prentice Hall, 2010, Section 7-4, Log-Magnitude-versus-Phase Plots, and Section 7-8, on the closed-loop frequency response and the Nichols chart
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W4 complete |
|
Tag EEHH4A Edit this page History Report an error Markdown