Techniqueintro
Root locus
Also called Evans root locus.
The paths of the closed-loop poles, the roots of D(s) + K N(s), as one gain K goes from 0 to infinity. Used to choose the gain and to place compensator poles and zeros.
The root locus of a loop is the set of paths that the closed-loop poles follow as one gain of the loop goes from 0 to infinity. For the unity feedback loop with the loop transfer function and , the closed-loop poles are the roots of . Evans showed in 1948 that the paths can be drawn by hand from the poles and zeros of alone, with a few rules, and that one picks the gain from the drawing. The method turns time-domain specifications into a place in the plane where the dominant poles must be, and shows whether a gain alone can put them there or a compensator is needed. Today the roots are computed, but the rules still explain the shape of the paths and the effect of each added pole and zero.
In plain words
When you turn up the gain of a feedback loop, its behavior changes: it gets faster, then it starts to ring, and at some gain it may become unstable. The behavior of a linear loop is set by a few numbers called its poles. The root locus is a picture of where these poles go as the gain grows. Each pole starts at a point fixed by the plant and moves along a curve. Some curves end at other fixed points of the plant, and the others run off to infinity along straight lines. From the picture you can read the gain that gives a wanted amount of ringing, the gain at which the loop goes unstable, and whether an extra part in the controller would bend the curves to a better place.
When it applies
- One parameter that enters linearly. The characteristic polynomial must have the form with real. A gain in a unity feedback loop gives this form. So does any parameter that enters a characteristic polynomial linearly: write and draw the locus of .
- Rational . is a real rational function with poles and zeros, . A time delay gives infinitely many branches; replace it by a Padé approximation first, and know that the result is approximate.
- One input and one output. For a multivariable loop, the locus of one gain with all other gains fixed is still defined, but the rules for its shape do not carry over in a simple way.
- The angle and magnitude conditions. A point is on the locus for some if and only if degrees for an integer , and then . All rules follow from these two conditions; see root locus rules.
The template
ROOT-LOCUS-DESIGN(G, specs)- 1
write G = N/D with N and D monic; the closed-loop poles are the roots of D + K N - 2
turn specs into a target region for the dominant pair ▷ zeta ≥ zeta_min, zeta omega_n ≥ sigma_min - 3
draw the locus: the rules for its shape, or the roots of D + K N on a grid of K - 4
if a branch crosses the target region at a point s* then - 5
K ← 1 / |G(s*)| ▷ magnitude condition - 6
else - 7
add a compensator pole or zero to G (lead: pull the locus left; lag: raise the low-frequency gain), then go to L3 - 8
find all closed-loop poles for this K, check that the others are far to the left of s* - 9
check the closed-loop zeros, simulate the step response, check the margins; if a check fails, go to L2 or L7 - 10
return the controller
The target region of line L2 comes from the step response specifications of the standard second-order system: a bound on the overshoot gives a minimum damping ratio, a sector around the negative real axis, and a bound on the settling time gives a minimum value of , a half plane. Line L8 is needed because these formulas hold for a dominant pair only. Line L9 is needed because the locus shows only the poles; the zeros of stay zeros of the closed loop and change the response.
Classic examples
A gain on a third-order plant. Let , so , . The real axis segments of the locus are and . Three asymptotes leave the centroid at 60, 180 and 300 degrees. The two branches from 0 and meet at the breakaway point , at , and leave the real axis. They cross the imaginary axis at for , which is the gain margin of the loop with (see gain margin and the Routh-Hurwitz criterion). For an overshoot near 16 percent take : the ray at 120 degrees meets the locus at ( rad/s), and . The third closed-loop pole is . A simulation of the step response gives the overshoot 15.54 percent and the 2 percent settling time 12.49 s.
The ultimate gain for Ziegler-Nichols tuning. For , the characteristic polynomial is . The three branches leave the triple pole at 60, 180 and 300 degrees and move along straight lines; two of them cross the imaginary axis where , at rad/s with . The ultimate gain 8 and the period s are the inputs of the closed-loop Ziegler-Nichols tuning rules.
A lead compensator. The first example settles slowly because the dominant pair is at . To make it about twice as fast with the same damping, aim at , , that is . The angle of is not degrees there, so no gain puts a pole at . A lead-lag compensator puts its zero on the plant pole at and its pole at , where the angle condition at holds. The loop with has the closed-loop polynomial . The simulated overshoot is 15.81 percent and the 2 percent settling time is 5.52 s instead of 12.49 s. The velocity error constant rises from 0.519 to 1.219 1/s. The cancelled pole at is stable, so the cancellation is harmless here; it would not be for an unstable pole.
Complex poles and a zero. For the poles are . The branch leaves at the departure angle 135 degrees, moves on the circle of radius around the zero , and meets the real axis at for . Then one branch goes to the zero and one goes to . Every gain gives a stable loop, and along the circle the damping ratio of the complex pair rises from 0.707 to 1.
Variations
- Negative gain. For the angle condition becomes degrees. This complementary locus (the zero degree locus) is needed when has a negative leading coefficient, as with some plants that have a zero in the right half plane.
- Root contours. With two parameters, draw a family of loci, one for each value of the second parameter.
- Discrete time. For a sampled loop with the period , the same rules give the locus in the plane, and the target region is inside the unit circle. The curves of constant damping ratio map to spirals.
- Other parameters. The locus over a time constant or a pole location, after the polynomial is rewritten as , shows the sensitivity of the poles to that parameter.
- Numerical root locus. A program finds the roots of on a grid of and joins them into branches. This is what design tools draw; the rules then serve to check the plot and to choose the grid near breakaway points and imaginary axis crossings.
Pitfalls
- Dominance is assumed. The formulas for the overshoot and the settling time hold for a pair of poles when all other poles and zeros are far away. In the first example a third pole 7 times farther away still moves the peak time from 5.44 s to 5.93 s. Check by simulation (line L9).
- Zeros are not on the picture. A zero of near the dominant pair raises the overshoot. A zero in the right half plane gives undershoot, and a branch that ends there makes the loop unstable at high gain.
- Cancelling an unstable pole or zero. A compensator zero on an unstable plant pole hides an unstable mode: the locus looks fine and the loop is not internally stable (see feedback control loop). Cancelling a slow stable pole inexactly leaves a slow closed-loop pole with a small residue, a long tail in the step response.
- The sign and scale of . The rules assume and monic and . If the leading coefficients have opposite signs, the 180 degree locus is the wrong one.
- Multiple roots are hard to compute. Near a breakaway point the closed loop has a double root, and computed roots are sensitive there (see root conditioning). A plot that jumps between branches near such a point is a numerical effect, not a property of the loop.
Exercises
- For , find the gain for . (Answer: the closed loop has , so and .)
- For , find where the locus crosses the imaginary axis, with the Routh array of . (Answer: , .)
- Show that the branches of are the segment and the vertical line . (Hint: the closed-loop poles are .)
References
- W. R. Evans, Graphical analysis of control systems, Transactions of the American Institute of Electrical Engineers 67(1) (1948) 547-551, the whole paper (the angle and magnitude conditions and the graphical construction of the locus)
- W. R. Evans, Control system synthesis by root locus method, Transactions of the American Institute of Electrical Engineers 69(1) (1950) 66-69, the whole paper (the choice of gain and compensation from the locus)
- Gene F. Franklin, J. David Powell and Abbas Emami-Naeini, Feedback Control of Dynamic Systems, eighth edition, Pearson, 2019, Chapter 5, The Root-Locus Design Method
- Karl J. Åström and Richard M. Murray, Feedback Systems, An Introduction for Scientists and Engineers, second edition, Princeton University Press, 2021, Chapter 12, Frequency Domain Design (the section The Root-Locus Method)
Where this leads
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W2 basic |
|
Tag QR5VW2 Edit this page History Report an error Markdown