MRI reconstruction
Problems
- MRI reconstruction
Recover the magnetization image from samples of its Fourier transform taken along k-space trajectories by one or more receive coils.
intro - Partial Fourier reconstruction
Recover an image from a little more than half of k-space by using the conjugate symmetry of the transform of a real image with a smooth phase.
core - Quantitative susceptibility mapping
Recover the magnetic susceptibility map from the measured field map, which is its convolution with a dipole kernel that vanishes on a cone.
advanced
Algorithms
- Root sum of squares coil combination
Combines the images of the coils into one magnitude image: the square root of the sum of the squared coil magnitudes at each pixel, after optional noise whitening. Needs no coil maps.
1 languagesintro - GRAPPA
Fills the skipped k-space lines of each coil with a small shift-invariant kernel over the acquired neighbors of all coils, fitted by least squares on a fully sampled center block. Needs no coil maps.
1 languagescore - Homodyne reconstruction
Reconstructs an MR image from partial k-space: double the unpaired high frequencies, remove a low resolution phase estimate and keep the real part. Exact for a real image with a constant phase.
1 languagescore - SENSE
Unfolds an aliased image from uniformly undersampled multi-coil Cartesian data by solving a small least squares problem with the coil sensitivities at each pixel. Needs R <= c.
1 languagescore - CG-SENSE
Solves the SENSE least squares problem for any k-space trajectory with the conjugate gradient method on the normal equations, with the coil encoding operator and its adjoint by FFT or nonuniform FFT.
1 languagesadvanced - Conjugate phase reconstruction
Reconstructs each pixel by weighting every k-space sample with its density weight and the conjugate of its predicted phase, field map term included: the adjoint of the signal model.
1 languagesadvanced - Density compensation
Weights for non-Cartesian k-space samples, found by the Pipe-Menon fixed point iteration w <- w / (C w), so that the weighted samples convolved with the gridding kernel give a flat density.
1 languagesadvanced - POCS partial Fourier reconstruction
Rebuilds an MR image from partial k-space by alternate projections onto the images with a low resolution phase and onto the images that agree with the measured samples.
1 languagesadvanced - SPIRiT
Finds the missing multi-coil k-space samples for any sampling pattern by asking that every sample agree with a calibrated kernel over its neighbors, solved by CGLS with the acquired samples kept.
1 languagesadvanced - k-t BLAST
Undersample dynamic MRI in k-space and time on a lattice and unfold the aliases in x-f space with a prior from low resolution training data.
1 languagesadvanced - ESPIRiT
Estimates coil sensitivity maps from calibration k-space: the null space of the calibration matrix defines a small matrix at each pixel, and its eigenvector with eigenvalue 1 is the map.
1 languagesresearch - LORAKS
Reconstruct undersampled MRI by asking that matrices built from local k-space neighborhoods have low rank, which follows from limited support or smooth phase.
1 languagesresearch - Low-rank plus sparse dynamic MRI
Reconstruct a dynamic image series as the sum of a low rank background and a sparse dynamic part by proximal steps on nuclear and L1 norms.
1 languagesresearch - Slice-GRAPPA
Separates slices that were excited at the same time: one GRAPPA-type kernel per slice maps the collapsed k-space of all coils to the k-space of that slice, fitted on single-slice calibration data.
1 languagesresearch - Variational network
An unrolled gradient scheme for MRI whose regularizer filters and activation functions are learned from pairs of undersampled and full data.
1 languagesresearch
Techniques
- Compressed sensing MRI
Undersample k-space at random and reconstruct by minimizing a sparsity penalty, such as wavelet L1 and total variation, subject to data consistency.
advanced - PROPELLER
Acquire k-space in rotated strips that each cover the center, so that rotation and shift between strips can be estimated and corrected.
advanced - Variable density sampling
Draw random k-space samples with a density that falls with distance from the center, where most of the energy of images lies.
advanced - MR fingerprinting
Vary the acquisition parameters pseudorandomly and match the signal evolution of each voxel to a dictionary simulated by the Bloch equations to get T1 and T2.
research
Concepts
- k-space
The spatial frequency domain in which MRI samples the image. The gradients move the sample point k(t) over time, and the spacing and extent of the samples set the field of view and the resolution.
intro - k-space trajectory
The path of the sampled spatial frequencies k(t) during a scan, set by the gradient waveforms. Cartesian lines, echo planar, radial and spiral paths differ in speed, reconstruction and artifacts.
core
Definitions
- Coil sensitivity map
The complex weight s_k(r) with which receive coil k sees the magnetization at the point r, so that coil k records the image s_k x. Parallel imaging uses the maps to replace skipped k-space lines.
core - Geometry factor
The noise amplification of a parallel imaging method at each pixel, beyond the sqrt(R) loss from fewer samples. For SENSE it is sqrt([M^-1]_pp [M]_pp) with M = E^H Psi^-1 E, and it is at least 1.
advanced
Models
- Bloch equations
The differential equations for the nuclear magnetization in a magnetic field, with precession and T1 and T2 relaxation. They predict the MR signal for a sample of independent spins.
1 languagescore - MRI signal equation
The received MRI signal at time t is the integral of coil sensitivity times magnetization times exp(-i 2 pi k(t) . r): a Fourier sample at k(t), the time integral of the gradient times gammabar.
core - Partial separability model
Model a dynamic image as a sum of few products of spatial and temporal functions, so that the space time matrix has low rank.
research