Also called low-rank model of dynamic MRI.

Model a dynamic image as a sum of few products of spatial and temporal functions, so that the space time matrix has low rank.

The partial separability (PS) model is a forward model for dynamic MRI. It says that the image series ρ(r,t)\rho(r, t) is a sum of LL products ul(r) vl(t)u_l(r)\, v_l(t) of a spatial function and a temporal function, with LL much smaller than the number of pixels and of frames. In k-space the same model reads s(k,t)=∑l=1Lcl(k) ϕl(t)s(k, t) = \sum_{l=1}^{L} c_l(k)\, \phi_l(t). So the space time (Casorati) matrix, with one row per pixel or k-space point and one column per frame, has rank at most LL. Liang (2007) proposed the model and a two step recovery: navigator data, acquired often but only near the center of k-space, give the temporal functions by an SVD; sparse imaging data then give the spatial functions by least squares. The model is the low rank part of L+S, which adds a sparse part, and it is close to the training step of k-t PCA in k-t BLAST.

The machine

The unknown. The image series ρ(r,t)\rho(r, t): a complex function of the position rr in the field of view and of the time tt. On a grid with NN pixels and TT frames it is the Casorati matrix X∈CN×TX \in \mathbb{C}^{N \times T}, whose column tt is frame tt and whose row nn is the time course of pixel nn.

The parameters.

  • The model order LL, a positive integer with L≪min⁡(N,T)L \ll \min(N, T).
  • The temporal functions ϕ1,…,ϕL\phi_1, \ldots, \phi_L, the rows of Φ∈CL×T\Phi \in \mathbb{C}^{L \times T}.
  • The spatial functions u1,…,uLu_1, \ldots, u_L, the columns of U∈CN×LU \in \mathbb{C}^{N \times L}, and their spectra cl=Fuulc_l = F_u u_l, the columns of C=FuUC = F_u U.
  • The sampling: the set of pairs (k,t)(k, t) that the scan acquires. Usually only a few k-space points are acquired in each frame.

The forward map. For each frame, the MRI signal equation with one uniform coil, applied to the model image:

ρ(r,t)=∑l=1Lul(r) vl(t),s(k,t)=∫ρ(r,t) e−2πi k⋅r dr+e(k,t)=∑l=1Lcl(k) ϕl(t)+e(k,t),\rho(r, t) = \sum_{l=1}^{L} u_l(r)\, v_l(t), \qquad s(k, t) = \int \rho(r, t)\, e^{-2\pi i\, k \cdot r}\, dr + e(k, t) = \sum_{l=1}^{L} c_l(k)\, \phi_l(t) + e(k, t),

where clc_l is the Fourier transform of ulu_l, ϕl=vl\phi_l = v_l, and ee is circular complex Gaussian noise. With several coils, each coil has its own clc_l, or the coil maps multiply ulu_l as in SENSE.

The discrete model. With the unitary DFT FuF_u applied to each frame and a mask Ω\Omega that keeps the acquired (k,t)(k, t) pairs,

X=UΦ,S=FuX=CΦ,y=Ω(S)+e.X = U \Phi, \qquad S = F_u X = C \Phi, \qquad y = \Omega(S) + e.

Here S∈CN×TS \in \mathbb{C}^{N \times T} is the k-space Casorati matrix: row kk is the time course of one k-space point.

Where it holds (heuristic). The model fits when few temporal patterns are shared by many pixels: periodic motion with few harmonics, contrast uptake curves, and slow signal changes. A pixel whose intensity follows a mix of these patterns adds no new term.

Where it fails (heuristic, with a measurement below).

  • Motion of edges. When an edge moves, each pixel near it has its own time course, and the rank grows with the size of the motion. In the example below one disk whose radius changes made the singular values fall slowly instead of stopping at 3.
  • Noise. Noisy data have full rank, so LL is a choice. Too small an LL leaves model error; too large an LL fits noise and asks for more samples per k-space point.
  • Events in few pixels at a few times, for example a bright spot that flashes once. These do not share a temporal pattern. L+S puts them in the sparse part.

What it counts

  • The data. One complex number per acquired (k,t)(k, t) pair and per coil.
  • The degrees of freedom (theorem). An N×TN \times T matrix of rank LL has L(N+T−L)L(N + T - L) complex degrees of freedom, against NTN T for a general matrix. The product UΦU \Phi has NL+LTN L + L T entries, and UΦ=(UG−1)(GΦ)U \Phi = (U G^{-1})(G \Phi) for every invertible L×LL \times L matrix GG, which removes L2L^2. For N=1282N = 128^2, T=256T = 256 and L=16L = 16 this is 265,984265{,}984 against 4,194,3044{,}194{,}304, a factor of 15.8.
  • What the fit minimizes. The two step method minimizes ∥PS−AΦ∥F\|P S - A \Phi\|_F over rank LL products on the navigator rows PSP S (the truncated SVD), then ∥yk−Φkc(k)∥2\|y_k - \Phi_k c(k)\|_2 for each k-space point kk, where Φk\Phi_k holds the columns of Φ\Phi at the frames in which kk was sampled. Other methods minimize ∥y−Ω(S)∥2\|y - \Omega(S)\|^2 with a rank constraint or a nuclear norm penalty on SS; there is no nuclear norm page.
  • The cost (real-ram). The SVD of the navigator matrix, of size p×Tp \times T, costs O(pTmin⁡(p,T))O(p T \min(p, T)). Each least squares fit costs O(mkL2)O(m_k L^2) for mkm_k samples, so all fits together cost O(ML2)O(M L^2) for MM samples. Forming the images costs O(NTL)O(N T L), plus TT FFTs of O(Nlog⁡N)O(N \log N) each.

A small example (measurement). A 32×3232 \times 32 series with T=40T = 40 frames: a static ellipse, a disk whose intensity is 0.6(1+0.3sin⁡(2πt/7.3))0.6(1 + 0.3 \sin(2\pi t/7.3)), like a heart, and a small disk with the uptake curve 0.4/(1+e−(t−15)/3)0.4 / (1 + e^{-(t - 15)/3}). This series is exactly PS of order 3. The scan acquires Cartesian lines: the center line ky=0k_y = 0 in every frame as the navigator, and 3 other lines per frame in a fixed cycle over the other 31 lines. That is 4 of 32 lines per frame, an acceleration of 8, and each line other than the center is acquired 3 or 4 times in the 40 frames. Errors are ∥X^−X∥F/∥X∥F\|\hat X - X\|_F / \|X\|_F.

method relative error
zero filled inverse DFT of each frame 0.490
view sharing (the nearest acquired frame for each line) 0.099
PS, two step, L=1L = 1 0.082
PS, two step, L=2L = 2 0.051
PS, two step, L=3L = 3 6.4×10−166.4 \times 10^{-16}

The singular values of XX, divided by the largest, were 1,0.063,0.0491, 0.063, 0.049 and then 1.5×10−161.5 \times 10^{-16}. Recovery with L=3L = 3 is exact up to rounding, as the theorems below predict. With L=4L = 4 the fit fails on the 4 lines that were acquired only 3 times.

When a fourth disk with the radius 3+sin⁡(2πt/7.3)3 + \sin(2\pi t/7.3) pixels is added, the singular values become 1,0.069,0.051,0.023,0.014,0.012,0.0095,0.00591, 0.069, 0.051, 0.023, 0.014, 0.012, 0.0095, 0.0059 and do not stop. With the same sampling, L=3L = 3 gave 0.046, against 0.031 for the best rank 3 approximation of the true XX and 0.118 for view sharing. With 5 lines other than the center per frame (an acceleration of 5.3, 6 or 7 acquisitions of each line), L=3,4,5,6L = 3, 4, 5, 6 gave 0.045, 0.032, 0.046 and 0.103. So a larger LL helps only until the extra temporal functions from the navigator are too weak to estimate well.

Relation to other models

  • MRI signal equation. Each frame follows the signal equation. The PS model adds a constraint across frames.
  • Principal component analysis and the Karhunen-Loeve transform. The temporal functions from the SVD are the principal components of the time courses (without the mean removed). So PS is PCA of the time courses with LL components.
  • k-t BLAST and k-t PCA. k-t BLAST uses low resolution training data to weight a reconstruction in x-f space. k-t PCA takes a temporal basis from such training data by PCA, which is the first step of the PS method in another form (heuristic comparison).
  • L+S and robust PCA. L+S writes X=L+SX = L + S with a low rank LL and a sparse SS. The PS model is the case S=0S = 0 with a fixed rank in place of the nuclear norm.
  • Matrix completion. Recovering a PS series from samples of SS is a low rank matrix recovery problem. Haldar and Liang (ISBI 2010) treated it this way. The completion theorems assume random samples and an incoherence condition; the PS navigator sampling is not random, so the deterministic theorems below are the ones that apply to it.
  • LORAKS. LORAKS also uses low rank, but of a structured matrix built from one k-space, not of the space time matrix.
  • MR fingerprinting. The simulated signal evolutions of an MRF dictionary are close to a low dimensional subspace, and subspace methods for MRF use the same UΦU \Phi form (heuristic comparison).

Known results in the model

Rank (theorem). If X=UΦX = U \Phi with U∈CN×LU \in \mathbb{C}^{N \times L} and Φ∈CL×T\Phi \in \mathbb{C}^{L \times T}, then rank⁡X≤L\operatorname{rank} X \le L, with equality if and only if rank⁡U=rank⁡Φ=L\operatorname{rank} U = \operatorname{rank} \Phi = L. The same holds for S=FuXS = F_u X.

Proof. rank⁡(UΦ)≤min⁡(rank⁡U,rank⁡Φ)≤L\operatorname{rank}(U \Phi) \le \min(\operatorname{rank} U, \operatorname{rank} \Phi) \le L. If both ranks are LL, then UU has a left inverse U+U^{+} with U+U=IU^{+} U = I, so Φ=U+X\Phi = U^{+} X and L=rank⁡Φ≤rank⁡XL = \operatorname{rank} \Phi \le \operatorname{rank} X. If one rank is less than LL, so is rank⁡X\operatorname{rank} X by the first inequality. FuF_u is invertible, so rank⁡S=rank⁡X\operatorname{rank} S = \operatorname{rank} X. □\square

Only the temporal subspace matters (theorem). If Φ^=GΦ\hat\Phi = G \Phi with GG invertible, then X=(UG−1)Φ^X = (U G^{-1}) \hat\Phi. So any basis of the row space of Φ\Phi describes the same set of images, and the spatial functions adjust to it.

The navigator gives the temporal subspace (theorem). Let PP select pp rows of SS (the navigator k-space points, acquired in every frame), and let A=PCA = P C, a p×Lp \times L matrix. If rank⁡A=L\operatorname{rank} A = L and rank⁡Φ=L\operatorname{rank} \Phi = L, then the row space of PSP S equals the row space of Φ\Phi. So the first LL right singular vectors of PSP S span it. This needs p≥Lp \ge L.

Proof. PS=AΦP S = A \Phi, so every row of PSP S is a combination of rows of Φ\Phi. AA has a left inverse A+A^{+}, so Φ=A+PS\Phi = A^{+} P S and every row of Φ\Phi is a combination of rows of PSP S. The two row spaces are equal, of dimension LL, so PSP S has exactly LL nonzero singular values and the first LL right singular vectors span the row space. □\square

One k-space point at a time (theorem). Fix Φ\Phi and a k-space point kk acquired in the frames t1,…,tmt_1, \ldots, t_m. Let Φk∈Cm×L\Phi_k \in \mathbb{C}^{m \times L} have the entries ϕl(tj)\phi_l(t_j), and let the data be yk=Φkc(k)+eky_k = \Phi_k c(k) + e_k. If rank⁡Φk=L\operatorname{rank} \Phi_k = L, the least squares solution c^(k)=Φk+yk\hat c(k) = \Phi_k^{+} y_k is unique and ∥c^(k)−c(k)∥2≤∥ek∥2/σmin⁡(Φk)\|\hat c(k) - c(k)\|_2 \le \|e_k\|_2 / \sigma_{\min}(\Phi_k). If rank⁡Φk<L\operatorname{rank} \Phi_k < L, there is a z≠0z \ne 0 with Φkz=0\Phi_k z = 0, and c(k)c(k) and c(k)+zc(k) + z give the same data. So each point needs m≥Lm \ge L samples, at frames where the temporal functions are linearly independent.

Proof. With full column rank, Φk+Φk=I\Phi_k^{+} \Phi_k = I, so c^(k)−c(k)=Φk+ek\hat c(k) - c(k) = \Phi_k^{+} e_k, and ∥Φk+∥2=1/σmin⁡(Φk)\|\Phi_k^{+}\|_2 = 1/\sigma_{\min}(\Phi_k). Without it, the null space of Φk\Phi_k is not trivial. □\square

Exact recovery (theorem). Without noise, if XX is exactly PS of order LL, the navigator condition above holds, and every k-space point has rank⁡Φk=L\operatorname{rank} \Phi_k = L, then the two step method returns XX exactly. This is a deterministic statement: it needs no random sampling. It follows from the last three theorems, applied with Φ^\hat\Phi from the SVD and C^=CG−1\hat C = C G^{-1}.

Model error (theorem, Eckart and Young 1936). For any XX with singular values σ1≥σ2≥⋯\sigma_1 \ge \sigma_2 \ge \cdots, the best approximation of rank LL in the Frobenius norm is the truncated SVD, with the error (∑i>Lσi2)1/2(\sum_{i > L} \sigma_i^2)^{1/2}. When the true series is only close to PS, this is the floor that no method in the model can go below. In the example above the floor for L=3L = 3 was 0.031 and the two step method reached 0.046.

Periodic sampling can break the fit (a measurement of the last condition). If the temporal functions, restricted to the frames in which a point kk was acquired, are linearly dependent, then Φk\Phi_k loses rank and the theorem above says that c(k)c(k) is not determined. A periodic motion and a periodic sampling order can cause this. In the example with the heart period changed from 7.3 to 10 frames, the line cycle of about 10.3 frames put the visits of 8 of the 32 lines at frames like 2, 12, 22 and 33, where sin⁡(2πt/10)\sin(2\pi t/10) has one value. Those 8 lines had condition numbers above 10610^{6} for L=3L = 3, and the error rose from 6.4×10−166.4 \times 10^{-16} to 0.0915. A sampling order that does not follow the period of the motion avoids this (heuristic).

Choosing the navigator (heuristic). Most of the energy of an image is near the center of k-space, so central navigator points give AA full rank with few samples in most images. The navigator also sets the time resolution: Φ\Phi is known only at the frames in which the navigator was acquired.

References

  1. Zhi-Pei Liang, Spatiotemporal imaging with partially separable functions, Proc. IEEE International Symposium on Biomedical Imaging (ISBI), 2007, 988 to 991, the partially separable model of order L and the two step recovery with navigator and imaging data (general locator)
  2. Carl Eckart and Gale Young, The approximation of one matrix by another of lower rank, Psychometrika 1(3), 1936, 211 to 218, the best approximation of lower rank by the truncated singular value decomposition (general locator)

About this page

The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.

LadderLevelWhat the next level needs
Human proofH0 no proof
  • add a proof in proofs/ (06.5)
LeanL0 no Lean part
  • name a Lean module in the lean field (07)
VisualV0 none
  • add viz/scene.ts or a figure (10)
WritingW4 complete
  • a review of the text: no review record reviews/ANWQA3/text.yaml