Algorithm Search⌘K

Problemadvanced

Quantitative susceptibility mapping

Also called QSM, dipole inversion.

Recover the magnetic susceptibility map from the measured field map, which is its convolution with a dipole kernel that vanishes on a cone.

Quantitative susceptibility mapping (QSM) is the problem of recovering the magnetic susceptibility χ(r)\chi(r) of tissue from the phase of MRI data. The tissue changes the main field B0B_0 a little, and the change is the convolution of χ\chi with the field of a unit dipole. In Fourier space the convolution is a product with the kernel D(k)=13−kz2/∣k∣2D(k) = \frac13 - k_z^2 / |k|^2, and DD is zero on a double cone at 54.7356 degrees to B0B_0. So the field does not see the frequencies of χ\chi on that cone, and the inversion, called dipole inversion, is ill-posed. Methods fill the gap with a prior, as in other deconvolution problems, or measure the field at several orientations of the head (COSMOS, Liu et al. 2009). Iron in the brain, calcium and the oxygen in venous blood all change χ\chi, which is why the map is useful.

In plain words

Every material becomes a weak magnet in a strong magnetic field. Iron becomes a slightly stronger magnet than water, and calcium a slightly weaker one. These small magnets change the field of the scanner nearby, and the change shows up in the phase of the MRI signal.

QSM works backward from the measured field change to the strength of the small magnets in each voxel. Each small magnet changes the field in a fixed pattern, with lobes along the field and a different sign to the sides. The measured field is the sum of all these patterns.

One family of patterns gives no field change at all, so the data cannot see it. QSM must guess that part, using prior knowledge, or rotate the head and scan again so that the hidden part changes.

Definition

The physical model. Let B0B_0 point along zz, and let δ(r)=(Bz(r)−B0)/B0\delta(r) = (B_z(r) - B_0)/B_0 be the relative field change. For an isotropic susceptibility with ∣χ∣≪1|\chi| \ll 1, to first order in χ\chi and with the Lorentz sphere correction,

δ=d∗χ,d(r)=3cos⁡2θr−14π∣r∣3,δ^(k)=D(k) χ^(k),D(k)=13−kz2∣k∣2,\delta = d * \chi, \qquad d(r) = \frac{3\cos^2\theta_r - 1}{4\pi |r|^3}, \qquad \hat\delta(k) = D(k)\, \hat\chi(k), \qquad D(k) = \frac13 - \frac{k_z^2}{|k|^2},

where θr\theta_r is the angle between rr and zz, and the convolution theorem turns the convolution into a product. D(0)D(0) is not defined, so χ\chi is determined at most up to a constant, and QSM gives values relative to a reference region. The model is an approximation: it ignores anisotropy of χ\chi (white matter has some), effects of the microstructure, and terms of second order in χ\chi.

From the data to the field. The phase of the image at the echo time TE\mathrm{TE} is φ(r)=φ0(r)±2πγˉ ΔB(r) TE\varphi(r) = \varphi_0(r) \pm 2\pi \bar\gamma\, \Delta B(r)\, \mathrm{TE}, with the sign set by the scanner convention. Phase unwrapping removes the jumps of 2π2\pi, and a fit over several echoes removes φ0\varphi_0. The result is the total field. It is the sum of the local field, from χ\chi inside the region of interest Ω\Omega (the brain), and the background field, from sources outside Ω\Omega such as the air in the sinuses. Background field removal estimates the local field δ\delta inside Ω\Omega.

The discrete problem (dipole inversion). On a grid of NN voxels with the periodic DFT FF,

δ=F−1diag⁡(D) Fχ+eon Ω,\delta = F^{-1} \operatorname{diag}(D)\, F \chi + e \quad \text{on } \Omega,

with noise ee whose variance depends on the magnitude of the image. Given δ\delta on Ω\Omega, find χ\chi. This page uses D(0)=0D(0) = 0 and real χ\chi.

Variants

  • Single orientation. One scan, the usual clinical case. A prior must fill the frequencies near the cone.
  • Several orientations (COSMOS). The head is scanned at non_o orientations to B0B_0. In the frame of the head each scan has its own kernel Di(k)=13−(k⋅bi)2/∣k∣2D_i(k) = \frac13 - (k \cdot b_i)^2 / |k|^2, where bib_i is the direction of B0B_0. The kernels have different cones, so the combined problem can be well conditioned.
  • Susceptibility tensor imaging. For anisotropic tissue, χ\chi is a symmetric 3×33 \times 3 tensor in each voxel, with six unknowns, so at least six orientations are needed.
  • Total field inversion. The background and local fields are fitted together, without a separate background removal step.
  • The field from several echoes. A fit of phase against echo time gives the field and its noise variance, which become the weights of the data term.

Examples

The kernel by hand. D(1,0,0)=13D(1, 0, 0) = \frac13, D(0,0,1)=13−1=−23D(0, 0, 1) = \frac13 - 1 = -\frac23, D(1,0,1)=13−12=−16D(1, 0, 1) = \frac13 - \frac12 = -\frac16 and D(1,1,1)=13−13=0D(1, 1, 1) = \frac13 - \frac13 = 0. Also D(1,7,5)=13−2575=0D(1, 7, 5) = \frac13 - \frac{25}{75} = 0. The zero set is 3kz2=∣k∣23 k_z^2 = |k|^2, that is cos⁡2θ=13\cos^2\theta = \frac13, the angle arccos⁡(1/3)=54.7356\arccos(1/\sqrt3) = 54.7356 degrees to the zz axis, the magic angle.

A sphere (theorem under the model). A ball of radius aa with uniform χ\chi gives, outside the ball, the field of one dipole at its center: δ(r)=χa3(3cos⁡2θ−1)/(3∣r∣3)\delta(r) = \chi a^3 (3\cos^2\theta - 1) / (3 |r|^3). This follows from the kernel, because dd is harmonic away from 00 (see Reductions) and so its mean over a ball equals its value at the center. Inside the ball, with the Lorentz correction, δ=0\delta = 0. So the field outside the ball tells only χa3\chi a^3, not χ\chi and aa apart.

A numerical example (measurement). A 32332^3 phantom: an ellipsoid with χ=0.02\chi = 0.02 and three balls with 0.150.15, −0.1-0.1 and 0.080.08 (in arbitrary units), mean removed. The field is computed with the periodic model, and Gaussian noise with a standard deviation of 1 percent of the largest field value is added. The table gives ∥χ^−χ∥2/∥χ∥2\|\hat\chi - \chi\|_2 / \|\chi\|_2. The same model makes and inverts the data, so these errors are smaller than with real data.

method relative error
division by DD where D≠0D \ne 0, without noise 0.246
division by DD where D≠0D \ne 0, with noise 3.08
truncated k-space division, threshold 0.05, 0.1, 0.2, 0.3 0.482, 0.404, 0.401, 0.458
Tikhonov in k-space, α=10−4,10−3,10−2,0.03\alpha = 10^{-4}, 10^{-3}, 10^{-2}, 0.03 0.615, 0.422, 0.416, 0.510
3 orientations: B0B_0 tilted by 0, 25 degrees about xx, 25 degrees about yy 0.106
5 orientations: 0 and ±25\pm 25 degrees about xx and about yy 0.072

Without noise, all the error of the first row comes from the 153 grid frequencies (of 32332^3) where DD is exactly zero. They hold 6.1 percent of the energy of χ\chi, and 0.061=0.246\sqrt{0.061} = 0.246. The 8 low frequencies (±1,±1,±1)(\pm1, \pm1, \pm1) alone hold 5.3 percent. With noise, division by the small values of DD near the cone makes the error 3.08. The single orientation methods trade this noise for a bias near the cone, and their best errors were 0.401 and 0.416. Three tilted orientations have no common zero on the grid; the smallest value of ∑iDi(k)2\sum_i D_i(k)^2 over k≠0k \ne 0 was 0.040.

Known algorithms

method data what it does
Truncated k-space division (TKD) one orientation divides by DD where ∣D∣>t\lvert D \rvert > t and by ±t\pm t elsewhere; two FFTs, O(Nlog⁡N)O(N \log N); where ∣D∣<t\lvert D \rvert < t it divides by tt in place of ∣D∣\lvert D \rvert, so it shrinks those frequencies, which gives streaks along the cone and values that are too small
Tikhonov in k-space one orientation χ^=F−1[Dδ^/(D2+α)]\hat\chi = F^{-1}[D \hat\delta / (D^2 + \alpha)], the closed form of Tikhonov regularization with the identity; O(Nlog⁡N)O(N \log N)
Weighted, Bayesian regularization (de Rochefort et al. 2010) one orientation, the magnitude image a data term weighted by the noise, with priors that regions of the background have zero susceptibility and that edges of χ\chi match edges of the magnitude image; solved iteratively
Edge weighted ℓ1\ell_1 and total variation one orientation, the magnitude image an ℓ1\ell_1 penalty of the gradient, as in total variation denoising, with weights from the magnitude edges; solved by conjugate gradients on a smoothed form or by ADMM
COSMOS (Liu et al. 2009) non_o orientations weighted linear least squares; with equal weights, χ^(k)=∑iDi(k)δ^i(k)/∑iDi(k)2\hat\chi(k) = \sum_i D_i(k) \hat\delta_i(k) / \sum_i D_i(k)^2 for each kk, O(noNlog⁡N)O(n_o N \log N)
Learned methods one orientation a network trained on pairs of fields and maps; its accuracy is a measurement on its test data

Bounds

  • The forward operator (theorem). In the continuous setting on L2(R3)L^2(\mathbb{R}^3), the map χ↦d∗χ\chi \mapsto d * \chi is the Fourier multiplier DD, with −23≤D≤13-\frac23 \le D \le \frac13, so its norm is 23\frac23, reached along kzk_z.
  • No bounded inverse (theorem). DD is zero only on the cone, a set of measure zero, so the map is injective on L2L^2. But ∣D∣|D| takes values as small as we like near the cone, and the inverse is the multiplier 1/D1/D, which is unbounded. So the solution does not depend continuously on the data, and the problem is not well posed in the sense of Hadamard.
  • How much of k-space is near the cone (theorem). For directions uniform on the sphere, u=cos⁡θu = \cos\theta is uniform on [−1,1][-1, 1], so the fraction of directions with ∣D∣<ε|D| < \varepsilon is 1/3+ε−1/3−ε\sqrt{1/3 + \varepsilon} - \sqrt{1/3 - \varepsilon} for ε≤13\varepsilon \le \frac13, about 3 ε\sqrt3\, \varepsilon for small ε\varepsilon. For ε=0.05,0.1,0.2\varepsilon = 0.05, 0.1, 0.2 this is 0.087, 0.175 and 0.365. On a 32332^3 grid the measured fractions were 0.122, 0.242 and 0.472, larger because the cube holds many frequencies along its diagonals, which lie on the cone.
  • A discrete null space (theorem). On a cubic grid, every integer frequency with 2kz2=kx2+ky22 k_z^2 = k_x^2 + k_y^2, for example (1,1,1)(1, 1, 1), has D=0D = 0. Any χ\chi with its spectrum on these frequencies gives zero field, so no method can recover that part from one orientation.
  • Noise gain (theorem). TKD with threshold tt multiplies the noise at each frequency by at most 1/t1/t. Tikhonov multiplies it by ∣D∣/(D2+α)≤1/(2α)|D|/(D^2 + \alpha) \le 1/(2\sqrt\alpha), the maximum of x/(x2+α)x/(x^2 + \alpha) at x=αx = \sqrt\alpha.
  • Several orientations (theorem). At frequency kk, the least squares estimate from non_o orientations is unique if and only if ∑iDi(k)2>0\sum_i D_i(k)^2 > 0, and with white noise of variance σ2\sigma^2 in each field its variance is σ2/∑iDi(k)2\sigma^2 / \sum_i D_i(k)^2. Three orthogonal directions of B0B_0 are not enough: all three kernels vanish where (k⋅bi)2=∣k∣2/3(k \cdot b_i)^2 = |k|^2/3 for each ii, which is ∣kx∣=∣ky∣=∣kz∣|k_x| = |k_y| = |k_z|, the four diagonal lines. On the 32332^3 grid that left 121 common zeros, all on these lines (measurement).

Reductions

  • Dipole inversion to deconvolution. The field is a convolution of χ\chi with dd, so dipole inversion is a deconvolution with a known kernel, like image deblurring, and the Wiener filter and Tikhonov regularization apply in k-space.
  • Background removal to a harmonic problem. For r≠0r \ne 0, d(r)=14π∂z2(1/∣r∣)d(r) = \frac{1}{4\pi} \partial_z^2 (1/|r|), because ∂z2(1/∣r∣)=(3z2−∣r∣2)/∣r∣5\partial_z^2 (1/|r|) = (3 z^2 - |r|^2)/|r|^5. Since 1/∣r∣1/|r| is harmonic away from 00, so is dd. So the background field, made by sources outside Ω\Omega, satisfies the Laplace equation inside Ω\Omega, a Poisson equation with zero right side. Methods such as SHARP and the Laplacian boundary value method use this fact.
  • Phase to field. The field comes from the unwrapped phase, so QSM depends on phase unwrapping.
  • Several orientations to stacked least squares. COSMOS stacks the non_o diagonal systems, and the normal equations are diagonal in k-space.

Applications

  • Iron in the brain. Deep gray matter nuclei hold iron, which is paramagnetic (χ>0\chi > 0 relative to water). QSM measures it in studies of aging and of neurodegenerative diseases.
  • Calcium against blood. Calcifications are diamagnetic (χ<0\chi < 0) and blood products are paramagnetic. Both look dark in magnitude images, and the sign of χ\chi tells them apart.
  • Venous oxygen. Deoxyhemoglobin is paramagnetic, so the susceptibility of veins depends on the oxygen saturation of the blood.
  • White matter. Myelin is diamagnetic and anisotropic, which motivates susceptibility tensor imaging.

References

  1. Ludovic de Rochefort, Tian Liu, Bryan Kressler, Jing Liu, Pascal Spincemaille, Vincent Lebon, Jianlin Wu and Yi Wang, Quantitative susceptibility map reconstruction from MR phase data using bayesian regularization, validation and application to brain imaging, Magnetic Resonance in Medicine 63(1), 2010, pages 194 to 206 (dipole inversion with a weighted data term and priors from regions of zero susceptibility and from the edges of the magnitude image; general locator for the details)
  2. Tian Liu, Pascal Spincemaille, Ludovic de Rochefort, Bryan Kressler and Yi Wang, Calculation of susceptibility through multiple orientation sampling (COSMOS), a method for conditioning the inverse problem from measured magnetic field map to susceptibility source image in MRI, Magnetic Resonance in Medicine 61(1), 2009, pages 196 to 204 (the field measured at several orientations of the object to B0, and the susceptibility from weighted linear least squares; general locator for the details)

About this page

The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.

LadderLevelWhat the next level needs
Human proofH0 no proof
  • add a proof in proofs/ (06.5)
LeanL0 no Lean part
  • name a Lean module in the lean field (07)
VisualV0 none
  • add viz/scene.ts or a figure (10)
WritingW2 basic
  • a known algorithm
  • a contract.yaml