Algorithm Search⌘K

Theoremadvanced

Youla-Kucera parametrization

Also called Youla parametrization, Q-parametrization.

All controllers that internally stabilize a plant are given by one formula in a free parameter Q in RH-infinity. Every closed loop map is affine in Q.

The Youla-Kucera parametrization describes the set of all controllers that internally stabilize a given linear plant. Write the plant as a ratio of stable transfer functions, P=NM−1P = N M^{-1}, with factors that satisfy a Bezout identity (a coprime factorization). Then every stabilizing controller has the form C=(Y+MQ)(X−NQ)−1C = (Y + M Q)(X - N Q)^{-1} for exactly one proper stable parameter QQ, and every proper stable QQ that keeps CC proper gives a stabilizing controller. The four closed loop maps of the feedback loop are affine in QQ. So a search over stabilizing controllers, which is a nonconvex set, becomes a search over the vector space of stable transfer functions, and any convex specification on the closed loop maps stays convex. Youla, Jabr and Bongiorno (1976) and Kučera (1975) found the result independently. It is the start of the H2 and H-infinity design methods of the 1980s.

Statement

Notation. RH∞RH_\infty is the set of proper real rational transfer functions with all poles in the open left half plane. A square matrix over RH∞RH_\infty is a unit if its inverse is also in RH∞RH_\infty. The loop has negative feedback, as everywhere in this area: the plant PP and the controller CC are proper real rational matrices, e=r−ye = r - y, u=Ce+du = C e + d and y=Puy = P u. The loop is well posed if I+P(∞)C(∞)I + P(\infty) C(\infty) is invertible. It is internally stable if it is well posed and the four maps from (r,d)(r, d) to (e,u)(e, u) are in RH∞RH_\infty:

[(I+PC)−1−(I+PC)−1PC(I+PC)−1(I+CP)−1].\begin{bmatrix} (I + P C)^{-1} & -(I + P C)^{-1} P \\ C (I + P C)^{-1} & (I + C P)^{-1} \end{bmatrix}.

Theorem (Youla, Jabr and Bongiorno 1976; Kučera 1975). Let PP be a proper real rational p×mp \times m matrix with a doubly coprime factorization over RH∞RH_\infty: P=NM−1=M~−1N~P = N M^{-1} = \tilde M^{-1} \tilde N, with M,N,M~,N~,X,Y,X~,Y~M, N, \tilde M, \tilde N, X, Y, \tilde X, \tilde Y in RH∞RH_\infty and

[X~Y~−N~M~][M−YNX]=[I00I].\begin{bmatrix} \tilde X & \tilde Y \\ -\tilde N & \tilde M \end{bmatrix} \begin{bmatrix} M & -Y \\ N & X \end{bmatrix} = \begin{bmatrix} I & 0 \\ 0 & I \end{bmatrix}.

Then a proper real rational CC internally stabilizes PP if and only if

C=(Y+MQ)(X−NQ)−1=(X~−QN~)−1(Y~+QM~)C = (Y + M Q)(X - N Q)^{-1} = (\tilde X - Q \tilde N)^{-1}(\tilde Y + Q \tilde M)

for some Q∈RH∞m×pQ \in RH_\infty^{m \times p} with det⁡(X(∞)−N(∞)Q(∞))≠0\det(X(\infty) - N(\infty) Q(\infty)) \ne 0. The map from QQ to CC is one to one. For this CC,

(I+PC)−1=(X−NQ)M~,PC(I+PC)−1=N(Y~+QM~),C(I+PC)−1=M(Y~+QM~),(I + P C)^{-1} = (X - N Q)\tilde M, \qquad P C (I + P C)^{-1} = N(\tilde Y + Q \tilde M), \qquad C (I + P C)^{-1} = M(\tilde Y + Q \tilde M),

and (I+PC)−1P=(X−NQ)N~(I + P C)^{-1} P = (X - N Q)\tilde N. Each map is affine in QQ.

Stable plant. If P∈RH∞P \in RH_\infty, take N=N~=PN = \tilde N = P, M=M~=IM = \tilde M = I, X=X~=IX = \tilde X = I and Y=Y~=0Y = \tilde Y = 0. The theorem then says: CC stabilizes PP if and only if C=Q(I−PQ)−1C = Q(I - P Q)^{-1} with Q∈RH∞Q \in RH_\infty and I−P(∞)Q(∞)I - P(\infty) Q(\infty) invertible, and then (I+PC)−1=I−PQ(I + P C)^{-1} = I - P Q and PC(I+PC)−1=PQP C (I + P C)^{-1} = P Q.

A doubly coprime factorization exists for every proper real rational PP; state-space formulas come from a stabilizable and detectable realization (see coprime factorization). That page uses the loop u=Kyu = K y with the identity XM−YN=IX M - Y N = I. Its form is the one here with K=−CK = -C, YY replaced by −Y-Y and QQ replaced by −Q-Q.

In plain words

A controller can make an unstable plant behave well, but most controllers you try will fail. The set of the good ones has a strange shape, so it is hard to search. The theorem gives a map that turns this set into a simple one. Pick any stable transfer function QQ. Put it into a fixed formula built from the plant. The result is a controller that stabilizes the plant. Every stabilizing controller comes out of the formula for exactly one QQ. Also, the closed loop responses depend on QQ in a linear way, plus a constant. So if you want a small tracking error or a small noise gain, you search over stable QQ, and the problem is often convex.

Proof

The proof is given for a single-input single-output plant, where all factors commute. The multivariable proof follows the same steps with the doubly coprime identity in place of the scalar Bezout identity (Zhou, Doyle and Glover 1996, chapter 12). In the scalar case the identity says XM+YN=1X M + Y N = 1, with X~=X\tilde X = X, Y~=Y\tilde Y = Y, M~=M\tilde M = M and N~=N\tilde N = N.

Step 1: a test for internal stability. Let C=U/VC = U/V with U,V∈RH∞U, V \in RH_\infty coprime: RV+WU=1R V + W U = 1 for some R,W∈RH∞R, W \in RH_\infty. Every proper rational CC has such a factorization. Put Δ=MV+NU\Delta = M V + N U. Then

11+PC=MVΔ,P1+PC=NVΔ,C1+PC=MUΔ,PC1+PC=NUΔ,\frac{1}{1 + P C} = \frac{M V}{\Delta}, \quad \frac{P}{1 + P C} = \frac{N V}{\Delta}, \quad \frac{C}{1 + P C} = \frac{M U}{\Delta}, \quad \frac{P C}{1 + P C} = \frac{N U}{\Delta},

because 1+PC=1+(NU)/(MV)=Δ/(MV)1 + P C = 1 + (N U)/(M V) = \Delta/(M V). Claim: the loop is internally stable if and only if Δ\Delta is a unit of RH∞RH_\infty. If 1/Δ∈RH∞1/\Delta \in RH_\infty, the four maps are products of elements of RH∞RH_\infty. Conversely, let the four maps be in RH∞RH_\infty. Multiply the two Bezout identities:

1Δ=(XM+YN)(RV+WU)Δ=XRMVΔ+XWMUΔ+YRNVΔ+YWNUΔ,\frac{1}{\Delta} = \frac{(X M + Y N)(R V + W U)}{\Delta} = X R \frac{M V}{\Delta} + X W \frac{M U}{\Delta} + Y R \frac{N V}{\Delta} + Y W \frac{N U}{\Delta},

which is in RH∞RH_\infty. Well-posedness is part of this: 1/Δ1/\Delta is proper.

Step 2: every Q gives a stabilizing controller. Let Q∈RH∞Q \in RH_\infty with X(∞)−N(∞)Q(∞)≠0X(\infty) - N(\infty) Q(\infty) \ne 0. Put U=Y+MQU = Y + M Q and V=X−NQV = X - N Q. Then

MV+NU=MX−MNQ+NY+NMQ=MX+NY=1.M V + N U = M X - M N Q + N Y + N M Q = M X + N Y = 1.

This identity also shows that UU and VV are coprime, with the coefficients MM and NN. VV is not zero at infinity, so C=U/VC = U/V is proper. By Step 1 with Δ=1\Delta = 1, the loop is internally stable, and the four maps are MVM V, NVN V, MUM U and NUN U: these are the formulas in the statement.

Step 3: every stabilizing controller comes from some Q. Let CC stabilize PP, and write C=U/VC = U/V coprime. By Step 1, Δ=MV+NU\Delta = M V + N U is a unit. Put U′=U/ΔU' = U/\Delta and V′=V/ΔV' = V/\Delta. They are in RH∞RH_\infty, C=U′/V′C = U'/V' and MV′+NU′=1M V' + N U' = 1. Define Q=XU′−YV′∈RH∞Q = X U' - Y V' \in RH_\infty. Use MX=1−NYM X = 1 - N Y:

Y+MQ=Y+MXU′−MYV′=Y+U′−Y(NU′+MV′)=U′,Y + M Q = Y + M X U' - M Y V' = Y + U' - Y(N U' + M V') = U',

and in the same way, with NY=1−MXN Y = 1 - M X, X−NQ=X−NXU′+NYV′=X+V′−X(NU′+MV′)=V′X - N Q = X - N X U' + N Y V' = X + V' - X(N U' + M V') = V'. So C=(Y+MQ)/(X−NQ)C = (Y + M Q)/(X - N Q). Also V′=1/(M+NC)V' = 1/(M + N C) and M+NCM + N C is proper, so V′(∞)=X(∞)−N(∞)Q(∞)≠0V'(\infty) = X(\infty) - N(\infty) Q(\infty) \ne 0.

Step 4: the map is one to one. If C=(Y+MQ)/(X−NQ)C = (Y + M Q)/(X - N Q), then the pair (U,V)=(Y+MQ,X−NQ)(U, V) = (Y + M Q, X - N Q) has MV+NU=1M V + N U = 1 by Step 2, and U=CVU = C V. So (M+NC)V=1(M + N C) V = 1 and V=1/(M+NC)V = 1/(M + N C) is fixed by CC. Then Q=(X−V)/NQ = (X - V)/N on the set where N≠0N \ne 0, and NN is not the zero function unless P=0P = 0. If P=0P = 0, take N=0N = 0, M=X=1M = X = 1 and Y=0Y = 0; then C=QC = Q. In both cases QQ is fixed by CC. □\square

Consequences

Example. P=1/(s−1)P = 1/(s - 1). Take N=1/(s+1)N = 1/(s + 1), M=(s−1)/(s+1)M = (s - 1)/(s + 1), X=1X = 1 and Y=2Y = 2, so that XM+YN=(s−1+2)/(s+1)=1X M + Y N = (s - 1 + 2)/(s + 1) = 1. For a constant Q=qQ = q:

C=2+q s−1s+11−qs+1=(2+q)s+2−qs+1−q.C = \frac{2 + q\,\frac{s - 1}{s + 1}}{1 - \frac{q}{s + 1}} = \frac{(2 + q) s + 2 - q}{s + 1 - q}.

The closed loop polynomial is (s−1)(s+1−q)+(2+q)s+2−q=s2+2s+1(s - 1)(s + 1 - q) + (2 + q) s + 2 - q = s^2 + 2 s + 1 for every qq. So q=0q = 0 gives the static gain C=2C = 2, q=1q = 1 gives the PI controller C=3+1/sC = 3 + 1/s, and q=−1q = -1 gives C=(s+3)/(s+2)C = (s + 3)/(s + 2). Each places both closed loop poles at −1-1, which are the poles of the factors and of QQ. The sensitivity is S=s−1s+1⋅s+1−qs+1S = \frac{s - 1}{s + 1} \cdot \frac{s + 1 - q}{s + 1}; it is 0 at the unstable pole s=1s = 1 for every qq. With q=1q = 1, S(0)=0S(0) = 0, so the PI controller has zero steady state error for a step reference.

  • Affine closed loop. With T1=XM~T_1 = X \tilde M, T2=NT_2 = N, T3=M~T_3 = \tilde M (scalar case), the sensitivity is T1−T2QT3T_1 - T_2 Q T_3. A weighted H-infinity problem min⁡C∥WS∥∞\min_C \|W S\|_\infty over stabilizing CC becomes the model matching problem min⁡Q∈RH∞∥W(T1−T2QT3)∥∞\min_{Q \in RH_\infty} \|W(T_1 - T_2 Q T_3)\|_\infty, which is convex in QQ (Zames 1981). The same holds for the H2 norm and for time domain bounds on step responses.
  • Internal model control. For a stable plant, C=Q/(1−PQ)C = Q/(1 - P Q) is the internal model control structure: the controller runs a copy of the plant model in parallel with QQ. The parameter QQ is the map from rr to uu, and PQP Q is the complementary sensitivity.
  • Interpolation conditions. For a scalar plant, S=M(X−NQ)S = M(X - N Q) vanishes at every unstable pole of PP (a zero of MM), and T=N(Y+MQ)T = N(Y + M Q) vanishes at every unstable zero of PP. These constraints hold for every stabilizing controller, and they cause the classical limits of performance, such as the Bode sensitivity integral.
  • All suboptimal H-infinity controllers. The set of controllers that meet an H-infinity bound is again an LFT in a free parameter, now with ∥Q∥∞<γ\|Q\|_\infty < \gamma (Glover and Doyle 1988; see the two-Riccati page).
  • Rule of thumb. In numerical design, QQ is often restricted to a finite expansion ∑kqkϕk\sum_k q_k \phi_k in fixed stable filters ϕk\phi_k, which gives a finite dimensional convex problem. This gives an upper bound on the true optimum, and the order of the controller grows with the number of filters.

Tightness

  • Q must be stable. For P=1/(s−1)P = 1/(s - 1) with the factors of the example in Consequences, Q=1/(s−2)Q = 1/(s - 2) gives S=M(X−NQ)=s−1s+1(1−1(s+1)(s−2))S = M(X - N Q) = \frac{s - 1}{s + 1}\bigl(1 - \frac{1}{(s + 1)(s - 2)}\bigr), which has a pole at s=2s = 2. The controller is proper, but the loop is not internally stable.
  • The properness condition cannot be dropped. For the stable static plant P=1P = 1 the formula is C=Q/(1−Q)C = Q/(1 - Q). The constant Q=1Q = 1 is in RH∞RH_\infty, but it gives X(∞)−N(∞)Q(∞)=0X(\infty) - N(\infty) Q(\infty) = 0, and no proper controller results.
  • Coprimeness cannot be dropped. The factors N=(s−1)/(s+1)2N = (s - 1)/(s + 1)^2 and M=(s−1)2/(s+1)2M = (s - 1)^2/(s + 1)^2 also give P=1/(s−1)P = 1/(s - 1), but they are not coprime, and no X,YX, Y satisfy the Bezout identity. With these factors the formula cannot be set up.
  • Internal stability, not only the map from r to y. The controller C=(s−1)/sC = (s - 1)/s cancels the unstable pole: PC=1/sP C = 1/s, and PC/(1+PC)=1/(s+1)P C/(1 + P C) = 1/(s + 1) is in RH∞RH_\infty. But P/(1+PC)=s/((s−1)(s+1))P/(1 + P C) = s/((s - 1)(s + 1)) has a pole at s=1s = 1. This CC is not in the parametrized set, as the theorem says.

History

Youla, Jabr and Bongiorno published the parametrization in 1976, in a two part paper on Wiener-Hopf design of optimal controllers, first for single-input single-output plants and then for multivariable plants. Kučera gave the same result for discrete-time plants with polynomial equations in 1975, and his name is often added for this reason. Zames (1981) used the parametrization for a stable plant to pose the H-infinity sensitivity problem, and the coprime factorization approach of the 1980s gave the form over RH∞RH_\infty used here (Zhou, Doyle and Glover 1996, chapter 12). The state-space solutions of the H2 and H-infinity problems later gave the controllers directly, but the parametrization remains the basis of convex controller design.

References

  1. Dante C. Youla, Joseph J. Bongiorno and Hamid A. Jabr, Modern Wiener-Hopf design of optimal controllers, Part I, The single-input-output case, IEEE Transactions on Automatic Control 21(1), 3-13, 1976, the description of all stabilizing controllers for a single-input single-output plant and its use in Wiener-Hopf design
  2. Dante C. Youla, Hamid A. Jabr and Joseph J. Bongiorno, Modern Wiener-Hopf design of optimal controllers, Part II, The multivariable case, IEEE Transactions on Automatic Control 21(3), 319-338, 1976, the parametrization of all stabilizing controllers for a multivariable plant with matrix fraction descriptions
  3. Vladimir Kučera, Stability of discrete linear feedback systems, IFAC Proceedings Volumes 8(1), 573-578, 1975, the parametrization of all stabilizing controllers of a discrete-time plant by polynomial equations
  4. George Zames, Feedback and optimal sensitivity, model reference transformations, multiplicative seminorms, and approximate inverses, IEEE Transactions on Automatic Control 26(2), 301-320, 1981, the weighted sensitivity problem, posed through the parametrization of the sensitivity of a stable plant
  5. Keith Glover and John C. Doyle, State-space formulae for all stabilizing controllers that satisfy an H-infinity norm bound and relations to risk sensitivity, Systems and Control Letters 11(3), 167-172, 1988, the parametrization of all controllers that meet an H-infinity norm bound
  6. Kemin Zhou, John C. Doyle and Keith Glover, Robust and Optimal Control, Prentice Hall, 1996, Chapter 5 (internal stability and coprime factorization over RH-infinity) and Chapter 12 (parametrization of all stabilizing controllers)

About this page

The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.

LadderLevelWhat the next level needs
Human proofH0 no proof
  • add a proof in proofs/ (06.5)
LeanL0 no Lean part
  • name a Lean module in the lean field (07)
VisualV0 none
  • add viz/scene.ts or a figure (10)
WritingW4 complete
  • a review of the text: no review record reviews/GEZP6T/text.yaml