Algorithm Search⌘K

Definitioncore

Transfer function matrix

Also called MIMO transfer function, transfer matrix of a multivariable system.

The p by m matrix G(s) = C(sI - A)^(-1)B + D whose entry (i, j) is the transfer function from input j to output i of a linear time-invariant system with m inputs and p outputs.

A transfer function matrix describes a linear time-invariant system with several inputs and several outputs. It is a matrix G(s)G(s) of transfer functions: the entry in row ii and column jj is the transfer function from input jj to output ii when all other inputs are zero. Because the system is linear, the Laplace transforms of the outputs are Y(s)=G(s) U(s)Y(s) = G(s)\, U(s) for a system at rest. For a state-space representation x′=Ax+Bux' = Ax + Bu, y=Cx+Duy = Cx + Du, the matrix is G(s)=C(sI−A)−1B+DG(s) = C(sI - A)^{-1}B + D. Many ideas of the scalar case carry over, but poles and zeros need a new definition, because the zeros of the matrix are not the zeros of its entries.

Definition

Notation. The system has mm inputs, pp outputs and nn states. R(s)\mathbb{R}(s) is the field of rational functions with real coefficients, and R(s)p×m\mathbb{R}(s)^{p \times m} the set of p×mp \times m matrices over it.

Definition. The transfer function matrix of a linear time-invariant system at rest is the G∈R(s)p×mG \in \mathbb{R}(s)^{p \times m} (or, with delays, a matrix of more general functions of ss) with

Y(s)=G(s) U(s)Y(s) = G(s)\, U(s)

for every input uu whose transform exists. Its entry Gij(s)G_{ij}(s) is the transfer function from uju_j to yiy_i. Equivalently, GG is the Laplace transform of the matrix impulse response g(t)g(t), whose column jj is the output for the input δ(t) ej\delta(t)\, e_j.

GG is proper if every entry is proper, so that G(∞)=lim⁡s→∞G(s)G(\infty) = \lim_{s \to \infty} G(s) exists, and strictly proper if G(∞)=0G(\infty) = 0.

From a state-space model. Transform x′=Ax+Bux' = Ax + Bu with x(0−)=0x(0^-) = 0 to get sX=AX+BUsX = AX + BU, so X=(sI−A)−1BUX = (sI - A)^{-1}BU and

G(s)=C(sI−A)−1B+D=D+∑k≥1CAk−1B s−k.G(s) = C (sI - A)^{-1} B + D = D + \sum_{k \ge 1} C A^{k - 1} B\, s^{-k}.

The matrices CAk−1BC A^{k - 1} B are the Markov parameters. So GG is proper with G(∞)=DG(\infty) = D, and each entry has a denominator that divides det⁡(sI−A)\det(sI - A). Conversely, every proper G∈R(s)p×mG \in \mathbb{R}(s)^{p \times m} has a state-space realization; this is the realization problem. The least state dimension among the realizations is the McMillan degree of GG, and a realization of that dimension is a minimal realization.

Poles and zeros. The set of poles of GG is the union of the poles of its entries. The multiplicities, and the zeros, are not read from the entries: they come from the Smith-McMillan form. The poles of GG with multiplicity are the eigenvalues of AA of a minimal realization, and the McMillan degree is their number. The zeros of GG are its transmission zeros.

Frequency response and size. For a system whose poles are all in the open left half plane, G(iω)G(i\omega) is the steady-state gain matrix for sinusoidal inputs of frequency ω\omega. Its largest and smallest singular values bound the gain of G(iω)G(i\omega) over all input directions, and the largest one over all ω\omega is the H-infinity norm. The steady-state gain for constant inputs is G(0)=−CA−1B+DG(0) = -CA^{-1}B + D when AA is invertible.

Feedback. With a controller KK and u=K(r−y)u = K(r - y), the output is y=(I+GK)−1GK ry = (I + GK)^{-1} G K\, r, and S=(I+GK)−1S = (I + GK)^{-1} is the sensitivity matrix. The order of the factors matters: (I+GK)−1(I + GK)^{-1} is p×pp \times p and (I+KG)−1(I + KG)^{-1} is m×mm \times m.

Examples and non-examples

  • From a state-space model. Take A=(01−2−3)A = \begin{pmatrix} 0 & 1 \\ -2 & -3 \end{pmatrix}, B=C=IB = C = I, D=0D = 0. Then det⁡(sI−A)=s2+3s+2\det(sI - A) = s^2 + 3s + 2 and
G(s)=1s2+3s+2(s+31−2s).G(s) = \frac{1}{s^2 + 3s + 2} \begin{pmatrix} s + 3 & 1 \\ -2 & s \end{pmatrix}.

Each entry has the poles −1-1 and −2-2.

  • Same entries, different degree. G1=diag⁡(1/(s+1),1/(s+1))G_1 = \operatorname{diag}(1/(s + 1), 1/(s + 1)) has McMillan degree 2: it needs two states, A=−I2A = -I_2. G2=(1/(s+1)1/(s+1))G_2 = \begin{pmatrix} 1/(s + 1) & 1/(s + 1) \end{pmatrix} has McMillan degree 1: A=−1A = -1, B=(11)B = \begin{pmatrix} 1 & 1 \end{pmatrix}, C=1C = 1. Both have the single pole −1-1, but with multiplicity 2 for G1G_1 and 1 for G2G_2.
  • A zero that no entry has. Let
G(s)=(1s+12s+31s+11s+1),det⁡G(s)=1−s(s+1)2(s+3).G(s) = \begin{pmatrix} \dfrac{1}{s + 1} & \dfrac{2}{s + 3} \\[2mm] \dfrac{1}{s + 1} & \dfrac{1}{s + 1} \end{pmatrix}, \qquad \det G(s) = \frac{1 - s}{(s + 1)^2 (s + 3)}.

No entry is zero at s=1s = 1, but G(1)=(1/21/21/21/2)G(1) = \begin{pmatrix} 1/2 & 1/2 \\ 1/2 & 1/2 \end{pmatrix} has rank 1, and the input direction (1,−1)(1, -1) is blocked there: s=1s = 1 is a transmission zero in the right half plane, which limits the performance of any feedback loop around GG. The steady-state gain is G(0)=(12/311)G(0) = \begin{pmatrix} 1 & 2/3 \\ 1 & 1 \end{pmatrix}.

  • Non-example: an improper matrix. (s1)\begin{pmatrix} s & 1 \end{pmatrix} is rational, but its first entry is a differentiator, which is not proper. It can describe an ideal model, but no (A,B,C,D)(A, B, C, D) model has it as its transfer matrix, since C(sI−A)−1B+DC(sI - A)^{-1}B + D is always proper.
  • Non-example: a time-varying system. A linear time-varying system x′=A(t)x+B(t)ux' = A(t)x + B(t)u has no transfer matrix: the response to este^{st} is not a multiple of este^{st}, and Y(s)=G(s)U(s)Y(s) = G(s)U(s) fails for every fixed GG.
  • Non-example: the entries alone. The list of entries, each read as a separate scalar system, does not show the poles and zeros of the matrix. In the zero example above, every entry is minimum phase, yet the matrix has a right half plane zero. Interaction measures such as the relative gain array are used to judge when the entries can be treated one by one.
  • Transfer function: the case m=p=1m = p = 1.
  • Transmission zero: a value of ss where GG loses rank below its normal rank.
  • Smith-McMillan form: the diagonal form that gives the poles and zeros of GG with multiplicities.
  • Minimal realization: a state-space model of GG with the least number of states, the McMillan degree.
  • Markov parameters: the coefficients CAk−1BC A^{k - 1} B of the expansion of GG at s=∞s = \infty.
  • H-infinity norm: the peak over frequency of the largest singular value of G(iω)G(i\omega).
  • Relative gain array: a measure of the interaction between the loops of a square GG.

References

  1. Sigurd Skogestad and Ian Postlethwaite, Multivariable Feedback Control, Analysis and Design, second edition, Wiley, 2005, Chapter 3, Introduction to Multivariable Control (transfer matrices, feedback rules and singular values), and Chapter 4, Elements of Linear System Theory (Sections 4.4 and 4.5, poles and zeros)
  2. Kemin Zhou, John C. Doyle and Keith Glover, Robust and Optimal Control, Prentice Hall, 1996, Chapter 3, Linear Dynamical Systems (state-space realizations of transfer matrices, and Section 3.11, Multivariable System Poles and Zeros)
  3. Thomas Kailath, Linear Systems, Prentice Hall, 1980, Chapter 6, State-Space and Matrix-Fraction Descriptions of Multivariable Systems

Where this leads

About this page

The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.

LadderLevelWhat the next level needs
Human proofH0 no proof
  • add a proof in proofs/ (06.5)
LeanL0 no Lean part
  • name a Lean module in the lean field (07)
VisualV0 none
  • add viz/scene.ts or a figure (10)
WritingW4 complete
  • a review of the text: no review record reviews/66MNEX/text.yaml