Techniqueintro
Block diagram reduction
Also called block diagram algebra.
Rules that merge series, parallel and feedback blocks of a linear diagram, and move summing and takeoff points, until one transfer function from the input to the output is left.
In plain words
A block diagram shows a linear system as boxes joined by arrows. Each box multiplies its incoming signal by a transfer function, each circle adds or subtracts signals, and each branch point copies a signal. Block diagram reduction replaces small patterns in the diagram by single boxes with the same input-output behaviour: two boxes in a row become their product, two boxes side by side become their sum, and a feedback loop becomes one fraction. When no pattern fits, one moves an adder or a branch point past a box, with a correction box, until a pattern appears. At the end one box is left, and its transfer function is the answer.
When it applies
- Every block is linear and time invariant, with a transfer function (a rational function, or one with a delay factor ). The result is the transfer function of the system at rest, with zero initial conditions.
- The diagram is well posed, so that each signal is uniquely defined. For proper blocks and a negative feedback loop with loop gain , this is .
- The diagram is small enough to reduce by hand, with a few nested loops. For a tangled diagram with many interlocking loops, Mason's gain formula is shorter, and for numeric work a state-space interconnection is safer.
- With several inputs and outputs, the blocks are matrices and the order of products matters. The same rules hold with the matrix forms below.
The template
The three merge rules, for scalar blocks:
| pattern | replaced by |
|---|---|
| then in series | |
| and in parallel into an adder | |
| forward block , feedback block , negative feedback | |
| forward block , feedback block , positive feedback |
The four move rules, which keep every signal that leaves the diagram unchanged:
| move | correction |
|---|---|
| adder from after to before | the side input passes through |
| adder from before to after | the side input passes through |
| branch point from after to before | the branch passes through |
| branch point from before to after | the branch passes through |
BLOCK-DIAGRAM-REDUCE(D, r, y)- 1
name every signal of D; check that each block is LTI and that D is well posed - 2
repeat - 3
merge every pair of blocks in series, and every pair in parallel - 4
pick a LOOP of D with no outside adder input or branch point between its blocks - 5
if such a loop exists then replace it by G / (1 + G H), with the SIGN of its adder - 6
else move one ADDER OR BRANCH POINT past one block by the move rules, to free a loop - 7
until D is one block from r to y - 8
write the block as N(s)/D(s), cancel common factors, and list each factor cancelled - 9
return the block
The holes are the choice of LOOP at L4 (innermost loops first keeps the algebra small), the SIGN convention at each adder, and the choice of ADDER OR BRANCH POINT to move at L6. Line L8 matters: each factor cancelled there is a mode that the input-output map does not show, and the pitfalls below explain when it is dangerous.
Why the feedback rule holds. With negative feedback, and , so and . When , .
A worked example. Take the diagram with the signals
No loop is free: the loop through starts at , after , and ends before , so the branch point of for sits inside it. Move the branch point for from back to ; by the move rules the branch now passes through , so the feedback block becomes . Now the loop around alone is free, and it becomes . In series with , inside the positive loop through , this gives
In series with and closed by the unity feedback of :
With , , , and , multiplying the top and the bottom by gives . Mason's formula gives the same result in one step: the three loops , and all pass through , so they all touch, and the one forward path touches all of them.
Classic examples
- The unity feedback loop. In the feedback control loop with controller and plant , the reference-to-output map is , and the disturbance at the plant input reaches the output through . Both are one application of the feedback rule.
- Cascade control. In cascade control, an inner loop with controller around the plant part is reduced first, to . The outer loop then sees , and the reference-to-output map is .
- The Smith predictor. In the Smith predictor, the controller has an inner feedback through the model . The feedback rule gives the equivalent controller . With the plant equal to the model , the reference-to-output map reduces to , so the delay leaves the characteristic equation.
- Internal model control. In internal model control, the controller acts on the error between the output and a model driven by the same input. The feedback rule turns this into an ordinary feedback controller .
- Two degrees of freedom. In two-degree-of-freedom control, with a prefilter . The series rule and the feedback rule give : shapes the response to without changing the loop.
Variations
- Mason's gain formula. The gain formula on the signal-flow graph of the diagram gives the result with no moves, from the paths and the loops.
- Several inputs and outputs. With matrix blocks, series is (the later block on the left), and negative feedback gives . The push-through rule moves a matrix past a loop. See transfer function matrix.
- State-space interconnection. Software connects the realizations of the blocks into one state-space model and reduces it to a minimal realization only at the end. This keeps every mode in view and is the safe form for numeric work.
- Linear fractional transformations. A linear fractional transformation writes any interconnection as one feedback loop between a fixed block and the part of interest, for example an uncertainty block.
Pitfalls
- Cancellation hides modes. A reduced transfer function can be stable while the system is not internally stable. With and , the reference-to-output map is , but the map from a disturbance at the plant input is , which is unstable (see poles and zeros). Check the four maps , , and of a loop (the gang of four), not one, where is the sensitivity function.
- Signs. Write the sign at each adder before reducing. A positive feedback loop gives in the denominator; a wrong sign here changes the closed-loop poles completely.
- Order of matrix products. With matrices, in general, and is not ; they even have different sizes when is not square.
- Algebraic loops. If for a loop, the signals are not defined, although the formula can still give a rational function. A loop around a constant gain is the plainest case.
- Moves through . The move rules that use need . If is strictly proper or has zeros in the right half plane, the intermediate diagram has an improper or an unstable block. This is fine as algebra, but that intermediate diagram is not a system one can build or simulate.
- Initial conditions. The result holds only for a system at rest. A response to initial conditions needs the state-space model or the Laplace transform with the initial values.
Exercises
- Two blocks and in parallel are closed by a negative feedback block . Show that the closed-loop map is .
- In the worked example, set and keep the other blocks. Show that .
- Reduce the worked example a second way: first move the adder of from before to after . Check that the result is the same.
- Show the push-through rule for matrices of compatible sizes, when both inverses exist. Hint: multiply on both sides.
- For the internal model control structure, show that if is stable and the plant equals the stable model , the reference-to-output map is .
References
- Katsuhiko Ogata, Modern Control Engineering, fifth edition, Prentice Hall, 2010, Chapter 2, Mathematical Modeling of Control Systems (block diagrams and their simplification)
- Gene F. Franklin, J. David Powell and Abbas Emami-Naeini, Feedback Control of Dynamic Systems, eighth edition, Pearson, 2019, Section 3.2.1, The Block Diagram, and Section 3.2.2, Block-Diagram Reduction Using Matlab
- Karl Johan Åström and Richard M. Murray, Feedback Systems, An Introduction for Scientists and Engineers, second edition, Princeton University Press, 2021, Chapter 9, Transfer Functions (block diagrams and transfer functions, and the gang of four)
- Sigurd Skogestad and Ian Postlethwaite, Multivariable Feedback Control, Analysis and Design, second edition, Wiley, 2005, Chapter 3, Introduction to Multivariable Control (transfer functions of block diagrams with several inputs and outputs, and the push-through rule)