Also called Fourier diffraction theorem.

Under the Born approximation the scattered field of each plane wave gives the object Fourier transform on an arc, which a Fourier method can invert.

Diffraction tomography reconstructs a weakly scattering object from the waves it scatters when plane waves from many directions pass through it. It is the version of computed tomography for wavelengths that are not small compared with the details of the object, as in ultrasound, microwaves and optical microscopy. There the waves bend around the object, and straight rays are a poor model. Under the first Born approximation the scattered field is linear in the object. The Fourier transform of the field measured on a line behind the object gives the Fourier transform of the object on a circular arc through the origin (Wolf 1969; Kak and Slaney, Chapter 6). In 3D the arc is a cap of a sphere. As the direction of the incident wave turns, the arcs fill a disk, and the object follows by interpolation onto a grid and an inverse FFT, or by the filtered backpropagation of Devaney (1982). When the wavelength goes to zero, the arcs become straight lines and the method becomes the Fourier slice theorem of straight ray tomography.

In plain words

In X-ray CT the rays go straight through the body, and each view gives one straight line through the centre of the Fourier transform of the image. Sound and microwaves do not go straight: they bend and spread around the details.

If the object changes the wave only a little, the part of the wave that it scatters is a sum of small waves from every point of the object. Measure that part along a line behind the object and take its Fourier transform. Each frequency of the measurement tells you one frequency of the object, but these frequencies lie on a circle and not on a line. Turn the source around the object, collect all the circles, and put them together to rebuild the object.

When it applies

  • Coherent waves of one frequency with a known wavenumber k0=2π/λk_0 = 2\pi / \lambda in the background medium. Broadband data are processed one frequency at a time.
  • Weak scattering. The first Born approximation needs a small total phase shift through the object. The Rytov approximation allows larger objects with small changes of the refractive index (Slaney, Kak and Larsen 1984 study both limits).
  • Measured amplitude and phase of the field on a line (2D) or a plane (3D) behind the object, for many directions of incidence.
  • Known incident field. The scattered field is the total field minus the field without the object.

Under these conditions, the theorem below links the data to the object.

The key theorem

Model. In 2D, the field uu solves (∇2+k02) u=−o(r) u(\nabla^2 + k_0^2)\, u = -o(r)\, u with the object function o(r)=k02(n(r)2−1)o(r) = k_0^2 (n(r)^2 - 1), where nn is the refractive index relative to the background. The incident field is the plane wave u0=eik0yu_0 = e^{i k_0 y}, and the scattered field is us=u−u0u_s = u - u_0.

Born approximation. Replace uu by u0u_0 on the right. Then us(r)=∫g(r−r′) o(r′) u0(r′) dr′u_s(r) = \int g(r - r')\, o(r')\, u_0(r')\, dr' with the Green's function g(r)=i4H0(1)(k0∣r∣)g(r) = \frac{i}{4} H_0^{(1)}(k_0 |r|) of the Helmholtz equation.

Theorem. Let O(K)=∫o(r) e−iK⋅r drO(K) = \int o(r)\, e^{-i K \cdot r}\, dr and let Us(α)=∫us(x,l) e−iαx dxU_s(\alpha) = \int u_s(x, l)\, e^{-i \alpha x}\, dx be the Fourier transform of the scattered field on the line y=ly = l, beyond the object. For ∣α∣<k0|\alpha| < k_0 and γ=k02−α2\gamma = \sqrt{k_0^2 - \alpha^2},

Us(α)=i2γ eiγl O(α, γ−k0).U_s(\alpha) = \frac{i}{2\gamma}\, e^{i \gamma l}\, O(\alpha,\, \gamma - k_0).

The points (α,γ−k0)(\alpha, \gamma - k_0) lie on the circle of radius k0k_0 centred at (0,−k0)(0, -k_0): an arc that passes through the origin.

Proof. The plane wave expansion of the Green's function is g(x,y)=i4π∫1γ ei(αx+γ∣y∣) dαg(x, y) = \frac{i}{4\pi} \int \frac{1}{\gamma}\, e^{i(\alpha x + \gamma |y|)}\, d\alpha, with γ\gamma imaginary and of positive imaginary part for ∣α∣>k0|\alpha| > k_0. Insert it into the Born formula with y=l>y′y = l > y':

us(x,l)=i4π∫1γ eiαx+iγl∫o(x′,y′) e−i(αx′+(γ−k0)y′) dx′ dy′ dα=12π∫i2γ eiγl O(α,γ−k0) eiαx dα.u_s(x, l) = \frac{i}{4\pi} \int \frac{1}{\gamma}\, e^{i \alpha x + i \gamma l} \int o(x', y')\, e^{-i(\alpha x' + (\gamma - k_0) y')}\, dx'\, dy'\, d\alpha = \frac{1}{2\pi} \int \frac{i}{2\gamma}\, e^{i \gamma l}\, O(\alpha, \gamma - k_0)\, e^{i \alpha x}\, d\alpha.

The right side is an inverse Fourier transform in xx, which gives the formula. □\square

The Fourier sign here is e−iK⋅re^{-i K \cdot r} with the angular frequency K=2πξK = 2\pi \xi, the convention e−2πix⋅ξe^{-2\pi i x \cdot \xi} of the encyclopedia. For ∣α∣>k0|\alpha| > k_0 the factor eiγle^{i\gamma l} decays: those components are evanescent and do not reach the detectors.

The template

  1. DIFFRACTION-TOMOGRAPHY(u for each view φ, k0, l)
  2. 1for each direction φ of the incident wave
  3. 2u_s ← u - u_0 ▷ Born; Rytov: u_0 ln(u / u_0)
  4. 3U_s(α) ← FFT of u_s along the detector line
  5. 4for each α with |α| < k0
  6. 5γ ← sqrt(k0² - α²)
  7. 6K ← α t(φ) + (γ - k0) s(φ) ▷ s: direction of the wave, t: the detector line
  8. 7O(K) ← (2γ / i) e^(-i γ l) U_s(α)
  9. 8put the values on the arcs onto a Cartesian grid ▷ hole: interpolation or filtered backpropagation
  10. 9o ← inverse 2D FFT of O
  11. 10return n ← sqrt(1 + o / k0²)

Lines L4 to L7 apply the theorem to one view, rotated so that the wave travels along s(φ)s(\varphi). Line L8 is the hard part. The samples lie on arcs, densely near the origin and sparsely far from it. Interpolation onto a grid is fast but its errors spread over the whole image (Pan and Kak 1983). Filtered backpropagation (Devaney 1982) instead filters each view and propagates it back into the object along the field of the wave, the analogue of filtered back-projection. A nonuniform FFT is a modern way to do line L8.

Classic examples

Coverage of the Fourier plane. For transmission data from all directions φ\varphi in [0,2π)[0, 2\pi), the arcs fill the disk ∣K∣≤2 k0|K| \le \sqrt{2}\, k_0. A detector line on the same side as the source records reflection data, which lie on the other half of each circle and reach ∣K∣=2k0|K| = 2 k_0. Ultrasound at 5 MHz in water (c=1540c = 1540 m/s) has λ=0.308\lambda = 0.308 mm and k0=20.4k_0 = 20.4 rad/mm, so transmission data reach ∣K∣=28.8|K| = 28.8 rad/mm.

A point scatterer. For o(r)=σδ(r)o(r) = \sigma \delta(r), O(K)=σO(K) = \sigma for all KK, and the theorem gives Us(α)=iσ2γeiγlU_s(\alpha) = \frac{i \sigma}{2 \gamma} e^{i \gamma l}, the plane wave expansion of the cylindrical wave σg(x,l)\sigma g(x, l). The data of every view are the same up to rotation, and the reconstruction is the point blurred by the disk of coverage.

The limit of short waves. As k0→∞k_0 \to \infty with α\alpha fixed, γ−k0→0\gamma - k_0 \to 0, and the arc becomes the straight line K=α t(φ)K = \alpha\, t(\varphi) through the origin. This is the Fourier slice theorem of X-ray CT, and filtered backpropagation becomes filtered back-projection.

Ultrasound computed tomography. Ring and cylindrical arrays around the breast record transmission data at many frequencies. Diffraction tomography gives the speed of sound and attenuation at a higher resolution than straight ray methods.

Optical diffraction tomography. Holographic microscopes measure the field of a cell for many directions of illumination and reconstruct its 3D refractive index on spherical caps, as in Wolf's original setting.

Variations

  • Rytov approximation. Use the complex phase u0ln⁡(u/u0)u_0 \ln(u / u_0) in place of u−u0u - u_0. It allows objects much larger than the wavelength if the index changes slowly.
  • Three dimensions. The arcs become spherical caps of radius k0k_0, and the data come from holograms on a plane.
  • Filtered backpropagation (Devaney 1982) instead of Fourier interpolation.
  • Broadband data. Several frequencies give arcs of several radii and fill the Fourier plane with fewer views.
  • Distorted Born iterations and full waveform inversion drop the weak scattering assumption by solving the nonlinear problem iteratively.
  • Limited angle and reflection geometries, where the coverage of the Fourier plane has gaps that a prior must fill.

Pitfalls

  • Strong scattering. The Born approximation fails when the phase shift through the object is more than a fraction of a turn. The reconstruction then shrinks or rings, and refining the data does not help.
  • Phase errors. The method needs the phase of the field. A drift of the source phase between views, or an error in ll, rotates the data on each arc. Measure or calibrate the incident field.
  • Evanescent components. The factor 1/γ1/\gamma grows near ∣α∣=k0|\alpha| = k_0, and noise there is amplified. Use a window that goes to zero at the edge of the arc.
  • Uneven sampling. The arcs cross near the origin, where the samples are dense, and spread apart at large ∣K∣|K|. Simple nearest neighbour interpolation onto a grid gives strong artefacts. Use a density weight and a good interpolator.
  • Wrong background. k0k_0 and the incident field must be those of the background medium, such as water at the right temperature.

Exercises

  1. Show that the points (α,k02−α2−k0)(\alpha, \sqrt{k_0^2 - \alpha^2} - k_0) lie on the circle of radius k0k_0 centred at (0,−k0)(0, -k_0), and find where the arc ends for ∣α∣→k0|\alpha| \to k_0.
  2. Show that the arcs of transmission data from all directions fill exactly the disk ∣K∣≤2 k0|K| \le \sqrt{2}\, k_0.
  3. Expand γ−k0\gamma - k_0 for ∣α∣≪k0|\alpha| \ll k_0 and show how far the arc is from the straight slice of X-ray CT at the frequency α\alpha.
  4. For a cylinder of radius aa with a constant index nn, estimate the phase shift of the wave through its centre, and find the largest aa for a phase shift of π/2\pi/2 at 5 MHz with n=1.02n = 1.02.
  5. Why does a source and detector pair on the same side of the object give information at higher spatial frequencies than transmission data?

References

  1. Emil Wolf, Three-dimensional structure determination of semi-transparent objects from holographic data, Optics Communications 1(4), 1969, 153, the Fourier transform of the object on a sphere from the scattered field, under the first Born approximation (general locator)
  2. R. K. Mueller, M. Kaveh and G. Wade, Reconstructive tomography and applications to ultrasonics, Proceedings of the IEEE 67(4), 1979, 567, diffraction tomography for ultrasound (general locator)
  3. A. J. Devaney, A filtered backpropagation algorithm for diffraction tomography, Ultrasonic Imaging 4(4), 1982, 336, the filtered backpropagation algorithm (general locator)
  4. S. X. Pan and A. C. Kak, A computational study of reconstruction algorithms for diffraction tomography: interpolation versus filtered backpropagation, IEEE Transactions on Acoustics, Speech, and Signal Processing 31(5), 1983, 1262, comparison of Fourier interpolation and filtered backpropagation (general locator)
  5. Malcolm Slaney, Avinash C. Kak and Lawrence E. Larsen, Limitations of imaging with first-order diffraction tomography, IEEE Transactions on Microwave Theory and Techniques 32(8), 1984, 860, the limits of the Born and Rytov approximations (general locator)
  6. A. C. Kak and M. Slaney, Principles of Computerized Tomographic Imaging, SIAM Classics in Applied Mathematics 33, 2001, Chapter 6 (tomographic imaging with diffracting sources)

About this page

The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.

LadderLevelWhat the next level needs
Human proofH0 no proof
  • add a proof in proofs/ (06.5)
LeanL0 no Lean part
  • name a Lean module in the lean field (07)
VisualV0 none
  • add viz/scene.ts or a figure (10)
WritingW2 basic
  • three classic examples