Definitionintro
Zero-crossing rate
Also called ZCR, zero-crossing count.
The fraction of adjacent samples in a frame whose signs differ, high for unvoiced fricatives and low for voiced speech.
The zero-crossing rate of a frame of audio is the fraction of pairs of adjacent samples whose signs differ. It is a cheap measure of how much of the energy of the frame lies at high frequencies: hiss such as "s" or "f" crosses zero often, and voiced speech, whose energy is mostly below 1 kHz, crosses rarely. It is a measurement of one frame, not a decision; a voice activity detector or the Rabiner-Sambur endpoint detector uses it, together with the energy, to decide which frames are speech, and a likelihood ratio VAD uses a model of the spectrum in its place.
Definition
Let be one frame with , and let for and for , so that 0 counts as positive. The zero-crossing count of the frame is
and the zero-crossing rate is , a number between 0 and 1. Some texts divide by in place of , some report itself per frame of fixed length, as Rabiner and Sambur do per 10 ms, and some report crossings per second, . Some count a crossing only when the product is negative, so that samples equal to 0 never count. All these variants are proportional to each other for frames of a fixed length, except for the treatment of zeros.
Facts that follow from the definition.
- Gain invariant (theorem). Multiplying the frame by any does not change . Multiplying by does not change it either when no sample is 0.
- Sinusoid (theorem, up to the frame edges). The sampled sinusoid with changes sign times per sample on average, so a frame of samples has about crossings.
- Gaussian noise (theorem). For a stationary zero-mean Gaussian sequence with normalized first autocorrelation , the probability that two adjacent samples differ in sign is , so the expected ZCR is . This is the cosine formula used by Kedem: .
- Not offset invariant. Adding a constant to the frame can change a lot. A DC offset larger than the signal makes .
Examples and non-examples
- A short frame. For the signs are , since 0.0 counts as positive. The sign changes between samples 2 and 3, 4 and 5, 6 and 7, and 7 and 8, so and .
- White noise. Independent zero-mean Gaussian samples have and .
- Low-pass noise. A first order autoregressive sequence with has an expected ZCR of 0.1436, and one with of 0.0638, about 10 crossings in a frame of 160 samples.
- A tone. At 16 kHz a 300 Hz tone has a ZCR of , about 6 crossings per 10 ms frame, and a 4 kHz tone has 0.5.
- Speech. Voiced frames have a low ZCR because their energy is mostly below 1 kHz, and unvoiced fricatives have a high one because their energy is mostly above 3 kHz. In the example of the Rabiner-Sambur endpoint detector, background frames have about 9 crossings per 160 samples and fricative frames between 62 and 96 (measurement on synthetic signals).
- Non-example: pitch. The ZCR of a voiced frame is not twice its fundamental frequency. Strong harmonics, such as a first formant at 700 Hz on a voice at 120 Hz, add crossings between the pitch periods. Pitch detection uses the autocorrelation or similar methods.
- Non-example: frequency of a mixture. For a sum of tones, the ZCR is not a weighted mean of their frequencies; a small high tone added to a large low one adds no crossings until its amplitude is large enough to make the sum change sign.
Related definitions
- Short-time energy. The energy , or the sum of magnitudes, of a frame. Together with the ZCR it separates silence, voiced and unvoiced frames in simple detectors.
- Autocorrelation. By the cosine formula, the ZCR of a Gaussian sequence determines its normalized first autocorrelation and back.
- Higher order crossings. Kedem's higher order crossings are the zero-crossing counts of the sequence after it has been differenced times. They describe the spectrum in more detail than the single count.
- Level-crossing rate. The rate at which the signal crosses a level , or a band of around 0, which makes the count less sensitive to low-level noise.
- Spectral centroid. The mean frequency of the power spectrum, a spectral measure that rises and falls with the ZCR on many signals, but needs an FFT.
References
- Benjamin Kedem, Spectral analysis and discrimination by zero-crossings, Proceedings of the IEEE 74(11), 1986, 1477 to 1493, the cosine formula that links the expected number of zero crossings of a stationary Gaussian sequence to its first autocorrelation, and the higher order crossings
- L. R. Rabiner and M. R. Sambur, An algorithm for determining the endpoints of isolated utterances, The Bell System Technical Journal 54(2), 1975, 297 to 315, the zero-crossing count of 10 ms frames and its use to find weak fricatives
- L. R. Rabiner and R. W. Schafer, Digital Processing of Speech Signals, Prentice Hall, 1978, Chapter 4 (time domain processing of speech), the short-time average zero-crossing rate
Where this leads