Definitioncore
Model resolution matrix
Also called resolution kernel.
For a linear estimate x_est = G y of y = A x + e, the matrix R = G A, so that x_est = R x_true when e = 0. Its rows show how each estimated value averages the true model.
The model resolution matrix of a linear estimate for the inverse problem is the matrix . For noise-free data, , so tells exactly how the estimate sees the truth: row shows which weighted average of the true model the -th estimated value is, and column shows the estimate of a spike at position . If , every value is resolved perfectly; a regularized estimate has , and the difference is its bias. The noise part of the estimate is measured separately, by and its covariance.
Definition
Let be the forward operator and a linear inverse, for example a pseudoinverse or a regularized inverse. With ,
- The model resolution matrix is .
- The resolution kernel (or averaging kernel) of the estimate is row of : when . In the continuous setting, , and is a kernel.
- The point spread function of the estimate at position is column of , the estimate of the unit spike .
- The data resolution matrix is , with predicted data . Since , the two matrices have the same trace.
From the definition follow three facts:
- The bias of the estimate is for zero-mean noise.
- The noise part has covariance when has covariance .
- annihilates the null space of : if , then . No linear method can resolve what the data do not see.
Measures of resolution. One number per estimate or per method:
- The Dirichlet spread , which is for perfect resolution.
- The Backus-Gilbert spread of row , (with a weight that grows with the distance from ), which is small when the row is a narrow peak at .
- The trace , read as the effective number of parameters that the data determine. In generalized cross-validation, is the number of degrees of freedom of the residual.
Spectral methods. For a filter method with spectral filter factors , and
So is symmetric, its eigenvalues are the filter factors, and .
Examples and non-examples
Least squares with full column rank. gives : perfect resolution and no bias. For an ill-conditioned this is a bad estimate, because is huge. Resolution alone does not measure quality.
Truncated SVD. , the orthogonal projection onto the first right singular vectors. Its trace is and its Dirichlet spread is . For the rectangle-rule matrix of the integration operator with and , row 12 (at ) of is . The peak is at the right place, but it is wide, and it has negative side lobes (down to ) and a far tail. The row sums to . These are the ringing and the loss of detail of the sharp cutoff (see truncated SVD).
Tikhonov regularization. , with . For the same matrix with , row 12 is at positions 7 to 17, and zero to three decimals elsewhere. It is a narrow positive peak, with and Dirichlet spread . This value of keeps more components than TSVD with , so it resolves more and amplifies more noise.
A diagonal check. For and Tikhonov with , . The first value is resolved, the second is halved, and the third is almost lost. The trace is exactly , since .
The linear Gaussian model. For the linear Gaussian inverse problem with prior covariance , the posterior mean has . The resolution and the posterior covariance are two views of the same matrix.
Backus-Gilbert. The Backus-Gilbert method picks each row of to make the resolution kernel of that estimate as narrow as possible under a bound on its variance. There the resolution matrix is the design goal, not a diagnostic.
Non-example: a nonlinear estimate. If the estimate is not a fixed linear map of , as for TSVD or Tikhonov with a parameter chosen from the data, for CGLS stopped by a rule, or for total variation, there is no single . A local resolution matrix can be defined from the derivative of the estimate with respect to the data, but it changes with .
Non-example: the data resolution matrix. acts on the data, not on the model. means the estimate fits the data exactly, which for noisy data is a sign of overfitting, not of good resolution.
Related definitions
- Spectral filter factors: the eigenvalues of for a filter method.
- Point spread function: the response of an imaging system to a point; the columns of are the point spread functions of the whole chain, measurement plus reconstruction.
- Regularization method: on the range of as the parameter goes to zero, which is the pointwise convergence for noise-free data.
- Linear Gaussian inverse problem: the posterior covariance, which measures the error that the resolution matrix leaves out.
References
- George Backus and Freeman Gilbert, The resolving power of gross earth data, Geophysical Journal of the Royal Astronomical Society 16(2), 1968, 169 to 205, the averaging (resolving) kernels of linear estimates, their spread, and the trade-off between resolution and error
- William Menke, Geophysical Data Analysis, Discrete Inverse Theory, fourth edition, Academic Press, 2018, the chapters Solution of the Linear Gaussian Inverse Problem, Viewpoint 2, Generalized Inverses (the model and data resolution matrices), and Nonuniqueness and Localized Averages
Where this leads
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W4 complete |
|
Tag WFYBWJ Edit this page History Report an error Markdown