Definitioncore
Miller coupling factor
Also called switch factor, coupling capacitance multiplier.
The factor, usually 0 to 2, by which a coupling capacitance is scaled when it is grounded for delay analysis, depending on whether the neighbor switches with or against the net.
Definition
A victim net is joined to a neighbor net, the aggressor, by a coupling capacitance , and to ground by . Delay calculators work with grounded capacitances. To fold into a grounded model, they replace it by to ground, so the victim sees . The number is the Miller coupling factor, also called the switch factor. The name comes from the Miller effect of amplifiers, where a capacitor between two nodes whose voltages move in opposite directions looks larger from one of them.
There are two common ways to fix . They agree in the simple cases and disagree in others, so a statement about must say which one it uses.
Charge-based factor. The victim voltage makes a transition of size that starts at , and its delay is measured at the threshold , usually , reached at . The aggressor voltage is . The charge that the victim driver must put on up to is , where is the change over . A grounded capacitance would take the charge , so
Delay-based factor. is the value for which the victim's threshold delay in the grounded model equals its delay in the coupled circuit.
The three textbook values come from the charge-based form with ramps of equal slew that start together: a quiet aggressor () gives ; an aggressor that switches in the same direction () gives ; an aggressor that switches in the opposite direction () gives .
Theorem (equal slews give 0 to 2). Let the victim be a ramp of rise time and the aggressor a ramp of the same swing and the same rise time, in either direction, starting at any time. Then .
Proof. The victim's window is , and . The aggressor's slope is at most in absolute value, so over a window of length it changes by at most : . Then .
Unequal slews go beyond 2. If the aggressor rise time is while the victim's is , the same argument gives , so
and both limits are reached: by an aggressor that ramps during the whole window when , and by one whose whole transition lies inside the window when . For and the range is . For example, a victim rising in 100 ps and an aggressor falling in 40 ps that starts at 5 ps finishes its whole swing before the victim reaches 50 percent at 50 ps, so and . Kahng, Muddu and Sarto (DAC 2000) showed by analysis of coupled RC lines that the switch factor ranges from to 3, not from 0 to 2, once slews and alignment vary.
Examples and non-examples
Delay-based factor of a step. The victim driver is a step from 0 to at through a resistance into , and joins the victim to an aggressor that steps from to 0 at the same instant. Let and . At charge sharing puts the victim at , and then , so the 50 percent delay is . The grounded model gives . Setting the two equal gives
which lies strictly between 2 and for . Both edges are steps, so the slews are equal, and still . The theorem above is about the charge-based factor with ramp waveforms that the coupling does not change. Here the coupling changes the victim waveform itself: it starts below 0.
| , opposite step | , same direction | |||
|---|---|---|---|---|
| 1 | 0.001 | 0.001 | 2.442 | |
| 9 | 1 | 0.1 | 2.375 | |
| 3 | 1 | 0.25 | 2.288 | |
| 1 | 1 | 0.5 | 2.170 | |
| 1 | 3 | 0.75 | 2.077 | delay 0, so |
For the same direction, and the delay is when , which gives . When the coupling alone lifts the victim to 50 percent at , the delay is 0, and only reproduces it: a smaller makes , and so the delay of the grounded model, negative.
Charge-based factor, aligned ramps. With equal ramps that start together and : quiet aggressor, , ; same direction, , ; opposite, , .
Not a Miller factor: the noise on a quiet victim. When the victim does not switch, and is undefined. The quantity of interest is then the noise peak, which the Devgan metric bounds.
Not a constant of the layout. depends on the waveforms, the alignment and the threshold, not only on the geometry. Parasitic extraction gives ; the factor comes from timing.
Related definitions
- Coupling capacitance : the capacitance between two nets, given by extraction. The victim's total capacitance in a grounded model is , and the Elmore delay or a nonlinear delay model then uses this value.
- Crosstalk delay. The change of the victim delay caused by coupling, the delay noise part of crosstalk noise. A factor slows the victim, and speeds it up.
- Timing windows. In static timing analysis, the aggressor can switch only inside its window of arrival times. If its window does not overlap the victim's transition, is safe. Tools iterate: the delays set the windows, and the windows set the factors.
- Switching power. The energy drawn from the supply per transition of the victim also depends on what the aggressor does, so dynamic power estimates that use are an average over aggressor activity.
- Common practice. Many flows use for setup checks (the victim slowed by an opposite aggressor) and for hold checks (the victim sped up). By the results above these values are not safe bounds in general when slews differ, and the delay-based factor of a step already exceeds 2.
References
- Andrew B. Kahng, Sudhakar Muddu and Egino Sarto, On switch factor based analysis of coupled RC interconnects, Proceedings of the 37th ACM/IEEE Design Automation Conference, 79 to 84, June 2000, the analysis of the switch factor under different slews and alignments of the aggressor, which gives the range from -1 to 3 in place of the usual range from 0 to 2
- Jan M. Rabaey, Anantha Chandrakasan and Borivoje Nikolic, Digital Integrated Circuits, A Design Perspective, 2nd edition, Prentice Hall, 2003, the chapter on coping with interconnect, section on capacitive crosstalk and its effect on delay
- John M. Miller, Dependence of the input impedance of a three-electrode vacuum tube upon the load in the plate circuit, Scientific Papers of the Bureau of Standards 15, 1920, the original Miller effect, a capacitance between the input and the output of an inverting amplifier of gain A that looks 1 + A times larger from the input
About this page
The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.
| Ladder | Level | What the next level needs |
|---|---|---|
| Human proof | H0 no proof |
|
| Lean | L0 no Lean part |
|
| Visual | V0 none |
|
| Writing | W0 stub |
|
Tag ZQ5VTR Edit this page History Report an error Markdown