Definitionintro
Fault coverage
Also called test coverage, fault efficiency.
The fraction of the faults of a fault list that a test set detects, with two related ratios that credit or exclude the faults proved undetectable.
Fault coverage is the fraction of the faults of a fault list that a test set detects. It is the main number that fault simulation gives, and the main measure of the quality of a manufacturing test. Two related ratios treat the faults that no test can detect in a different way: one counts the faults proved undetectable as covered, and one removes the undetectable faults from the count. A coverage number means little unless it says which ratio it is and which fault list it counts.
Definition
Let be a circuit, a finite list of faults of one fault model, for example the single stuck-at faults of the stuck-at fault model, and a set of tests. A test is an input vector for stuck-at faults, or a pair of vectors for delay faults. Write for the faults that some test of detects. Let be the faults that a tool has proved redundant, that is undetectable by any test, and let with be the faults that the tool classes as untestable for any reason, for example proved redundant or blocked by a constraint of the test setup.
The fault coverage of is
Two related ratios are in common use.
- The ratio that credits proved redundancy is . It reaches 1 exactly when every fault is either detected or proved undetectable, so it measures how complete the work of the test generator is.
- The ratio over the testable faults is . It removes the untestable faults from the denominator, so it measures how many of the faults that a test could find were found.
For the same , the fault coverage is never above either of the two others, since and . The three are equal when is empty. The names of the two related ratios are not the same in all tools and books, so a report should give the formula or the counts, not only a name.
The value also depends on the fault list . After fault collapsing, holds one fault per class of equivalent faults, and each class counts once. A class with many faults weighs as much as a class with one, so the collapsed and the uncollapsed coverage of the same test set differ.
Examples and non-examples
Same tests, two lists. Take , , with the stem and the branches and , which has 8 lines and 16 single stuck-at faults. The test set detects a/0, /0, g/1, /0, c/0, h/1, b/0 and z/0, so . At each NAND gate, an input stuck at 0 is equivalent to the output stuck at 1, which gives three classes of three faults: {a/0, /0, g/1}, {/0, c/0, h/1} and {g/0, h/0, z/1}. The collapsed list has classes. The same test set detects 4 of them, so its collapsed coverage is .
Redundant faults. The circuit , , , computes , and the term is the consensus of the two others. It has 14 lines and 28 faults. The faults r/0, /0 and /0 make , and stays the same function, so they are redundant. All 8 input vectors together detect the other 25 faults, and the four vectors 001, 010, 101 and 110 detect them too.
| tests | fault coverage | credit for | over testable | |||
|---|---|---|---|---|---|---|
| {110, 001} | 12 | 2 | 2 | 12/28 = 42.9% | 14/28 = 50.0% | 12/26 = 46.2% |
| {001, 010, 101, 110} | 25 | 2 | 2 | 25/28 = 89.3% | 27/28 = 96.4% | 25/26 = 96.2% |
| {001, 010, 101, 110} | 25 | 3 | 3 | 25/28 = 89.3% | 28/28 = 100% | 25/25 = 100% |
The first two rows assume that the tool proved r/0 and /0 redundant but stopped on /0 before a proof. The complete test set has a fault coverage below 100% in every row, because 100% is not reachable for this circuit. So a fault coverage below 100% does not mean that a test is missing.
Non-example: the fraction of vectors. The number of distinct vectors applied, divided by , is not a coverage. In the consensus circuit, 4 of the 8 vectors already detect every detectable fault.
Non-example: a fault list of another model. A test set with 100% stuck-at coverage can have a low coverage of transition faults, since a single vector does not launch a transition. A coverage number holds for one fault model only.
Related definitions
- Detected fault. A fault is detected by a test if the good circuit and the circuit with give different values at some primary output. For a pair of vectors, the second vector is the one that is observed.
- Redundant fault. A fault that no test detects. See redundant fault. Proving a fault redundant is as hard as automatic test pattern generation, so is often smaller than the set of all redundant faults.
- Aborted fault. A fault for which the test generator stopped, after a work limit, with neither a test nor a proof. It is in neither nor , and it lowers all three ratios.
- Multiple detection. The -detect coverage counts a fault as detected only if at least different tests detect it. See n-detect test.
- Defect level. The fraction of shipped chips that are bad. The Williams-Brown formula gives it from the yield and the fault coverage, under the assumption that every fault is equally likely.
References
- Michael L. Bushnell and Vishwani D. Agrawal, Essentials of Electronic Testing for Digital, Memory and Mixed-Signal VLSI Circuits, Kluwer, 2000, the chapters Fault Modeling and Logic and Fault Simulation (fault coverage, its ratios and the fault list they use)
- Miron Abramovici, Melvin A. Breuer and Arthur D. Friedman, Digital Systems Testing and Testable Design, IEEE Press, 1994, the chapters on fault simulation and test generation (fault coverage, undetectable faults and test quality)
- T. W. Williams and N. C. Brown, Defect level as a function of fault coverage, IEEE Transactions on Computers C-30(12), 987 to 988, 1981, the use of fault coverage to predict the fraction of bad chips that pass the test
Where this leads