Algorithm Search⌘K

Techniquecore

Controller discretization by emulation

Also called emulation design, digital redesign.

Designs a continuous controller and turns it into a discrete one by Tustin, matched pole-zero or hold equivalents.

Emulation design first designs a continuous controller C(s)C(s) by the usual tools, then replaces it by a discrete controller Cd(z)C_d(z) that runs on a computer with the sampling period hh. The plant still gets its input through a zero-order hold. The common maps are the Tustin (bilinear) map, Tustin with prewarping, the matched pole-zero map, the hold equivalent of CC, and the Euler maps. This page covers the choice among them and what each does to the margins of the loop. For the map s=(2/h)(z−1)/(z+1)s = (2/h)(z - 1)/(z + 1) itself and its use for filters, see the bilinear transform; for the exact discrete model of the plant, see zero-order hold discretization. The emulated loop is an approximation: the hold adds a delay of about h/2h/2, which costs phase margin, and this cost is the main check.

In plain words

Most controllers are designed with continuous formulas, but they run on a computer that reads the sensor and sets the actuator only at fixed times. Emulation keeps the continuous design and turns its formula into a rule that updates at each sample. There are several ways to do this. The best common way keeps the behaviour of the controller at low and middle frequencies close to the original and never turns a well-behaved controller into a badly behaved one. All ways have one cost that no formula removes: the actuator value is held between the samples, which acts like a small delay of half a sample. This delay reduces the safety margin of the loop. If the samples are frequent compared with the speed of the loop, the loss is small; if not, design the controller with the delay in mind or design it directly in discrete time.

When it applies

  • A continuous controller exists, or the designer prefers continuous tools such as loop shaping or PID rules.
  • The sampling is fast compared with the loop: the crossover frequency ωc\omega_c and the period hh give a small ωch\omega_c h, so that the loss ωch/2\omega_c h/2 rad of phase is acceptable.
  • An anti-aliasing filter before the sampler is in the design or its lag is small at ωc\omega_c; see aliasing.
  • If ωch\omega_c h is large, or the plant has fast dynamics near the Nyquist frequency π/h\pi/h, a direct discrete design on the exact sampled plant is better.

The template

  1. Design C(s)C(s) with some margin to spare for the hold: plan on losing about ωch/2\omega_c h/2 rad of phase margin (a rule of thumb from the delay of h/2h/2 of the hold).
  2. Choose hh. Take hh so that ωch/2\omega_c h/2 is a few degrees, and so that the anti-aliasing filter has little lag at ωc\omega_c.
  3. Map C(s)C(s) to Cd(z)C_d(z):
    • Tustin: s←2hz−1z+1s \leftarrow \dfrac{2}{h} \dfrac{z - 1}{z + 1}.
    • Tustin with prewarping at ω0\omega_0: s←ω0tan⁡(ω0h/2)z−1z+1s \leftarrow \dfrac{\omega_0}{\tan(\omega_0 h/2)} \dfrac{z - 1}{z + 1}, which makes CdC_d equal to CC exactly at ω0\omega_0, usually the crossover or a notch frequency.
    • Matched pole-zero: map each pole and zero pp to ephe^{p h}, put zeros at z=−1z = -1 for excess poles if wanted, and match the gain at s=0s = 0 (or at another frequency).
    • Hold equivalent: Cd(z)=(1−z−1) Z{C(s)/s}C_d(z) = (1 - z^{-1}) \, \mathcal{Z}\{C(s)/s\}, exact for inputs that are constant between samples.
    • Euler: forward s←(z−1)/hs \leftarrow (z - 1)/h or backward s←(z−1)/(hz)s \leftarrow (z - 1)/(h z).
  4. Write the difference equation. From Cd(z)=(b0+b1z−1)/(1+a1z−1)C_d(z) = (b_0 + b_1 z^{-1})/(1 + a_1 z^{-1}) comes uk=−a1uk−1+b0ek+b1ek−1u_k = -a_1 u_{k-1} + b_0 e_k + b_1 e_{k-1}. For PID controllers, see the PID controller page for the usual forms and the anti-windup.
  5. Check the sampled loop. Discretize the plant exactly with the zero-order hold, close the loop with CdC_d, and compute the phase margin, MsM_s and the closed-loop poles in zz (all inside the unit circle for an asymptotically stable loop).

What each map preserves (theorems).

  • Tustin. With z=ejωdhz = e^{j\omega_d h}, (z−1)/(z+1)=jtan⁡(ωdh/2)(z - 1)/(z + 1) = j \tan(\omega_d h/2). So Cd(ejωdh)=C(jω)C_d(e^{j\omega_d h}) = C(j \omega) with ω=(2/h)tan⁡(ωdh/2)\omega = (2/h) \tan(\omega_d h/2): the discrete response is the exact continuous response at a warped frequency. The map sends the open left half-plane onto the open unit disc, so a BIBO stable CC gives a BIBO stable CdC_d of the same order, and the gain at ω=0\omega = 0 is exact. Prewarping changes the constant so that ω0\omega_0 maps to itself.
  • Backward Euler sends the left half-plane into the disc ∣z−1/2∣<1/2|z - 1/2| < 1/2, so BIBO stability is kept.
  • Forward Euler sends a pole pp to 1+hp1 + h p, which is inside the unit circle if and only if ∣1+hp∣<1|1 + hp| < 1; for a real p<0p < 0 this needs h<2/∣p∣h < 2/|p|. It can turn a BIBO stable CC into a CdC_d that is not.
  • Matched pole-zero places the poles exactly at ephe^{p h}, the poles of the sampled version of CC.
  • Hold equivalent gives the exact samples of the output of CC when its input is held, so it treats the controller as if it had a hold at its input.

Classic examples

The lead network of the lead-lag page. Take P=10/(s(s+1))P = 10/(s(s + 1)) and the lead C=(1+0.45284s)/(1+0.11321s)C = (1 + 0.45284 s)/(1 + 0.11321 s) from the lead-lag compensator page: crossover 4.41659 rad/s, phase margin 49.63 degrees and Ms=1.42139M_s = 1.42139 in continuous time. The plant is discretized exactly with the zero-order hold, and the controller by each map. Measured phase margins of the sampled loop, in degrees; the column "rule" is 49.63−ωch/249.63 - \omega_c h/2 in degrees:

hh rule forward Euler backward Euler Tustin Tustin, prewarped at ωc\omega_c matched hold equivalent
0.01 s 48.36 49.13 47.61 48.36 48.36 48.35 48.82
0.02 s 47.10 48.65 45.61 47.10 47.10 47.04 47.88
0.05 s 43.30 47.31 39.71 43.30 43.33 42.98 44.23
0.1 s 36.98 45.50 30.25 36.94 37.13 35.76 35.15
0.2 s 24.32 43.64 12.83 24.14 25.34 20.25 7.20

Measured peak sensitivity MsM_s:

hh forward Euler backward Euler Tustin prewarped matched hold equivalent
0.05 s 1.514 1.762 1.638 1.636 1.647 1.661
0.1 s 1.597 2.295 1.935 1.921 1.985 2.153
0.2 s 1.644 5.308 3.030 2.849 3.495 10.502

All closed loops in the table have their poles inside the unit circle. What the numbers show:

  • Tustin follows the rule ωch/2\omega_c h/2 to within 0.2 degrees for all hh: the map itself is nearly exact near ωc\omega_c, and the loss is the hold.
  • Prewarping helps only a little here (25.34 against 24.14 degrees at h=0.2h = 0.2 s), since the warp moves ωc\omega_c only from 4.417 to 4.347 rad/s at h=0.1h = 0.1 s and to 4.159 rad/s at h=0.2h = 0.2 s.
  • The Euler maps turn the frequency variable: (ejωh−1)/h=ejωh/2(2j/h)sin⁡(ωh/2)(e^{j\omega h} - 1)/h = e^{j\omega h/2} (2j/h) \sin(\omega h/2), so forward Euler evaluates CC at jωj\omega turned by +ωh/2+\omega h/2, and backward Euler at jωj\omega turned by −ωh/2-\omega h/2. On this lead, backward Euler loses the most margin among the Euler and Tustin maps.
  • Forward Euler keeps the most phase margin on this lead, because its turn offsets part of the hold. This is a property of this example, not a rule: its controller pole 1−h/0.113211 - h/0.11321 is −0.767-0.767 at h=0.2h = 0.2 s, which makes uu alternate in sign from sample to sample, and for h>0.2264h > 0.2264 s the pole leaves the unit circle.
  • The hold equivalent of the lead raises the crossover (5.43 rad/s at h=0.1h = 0.1 s, 6.39 rad/s at h=0.2h = 0.2 s) and is the worst at large hh.

With ωch=0.22\omega_c h = 0.22 (at h=0.05h = 0.05 s) the loss is about 6 degrees, which most designs accept.

Variations

  • Discrete design. Discretize the plant exactly and design CdC_d in the zz-domain, by root locus or loop shaping in zz or by a state-space method. This avoids the approximation of emulation and is needed for slow sampling.
  • Account for the hold in the design. Add a delay e−sh/2e^{-sh/2}, or a Padé approximation of it, to the plant before the continuous design, then emulate. The design then sees the loss of phase and can make up for it.
  • Delta operator. Writing the discrete controller in the variable (z−1)/h(z - 1)/h improves the numerical behaviour at fast sampling, when the poles in zz crowd near 1.
  • PID specific forms. Backward differences for the derivative with the filter, forward or Tustin for the integral; see the PID controller page.
  • Digital redesign. Methods that choose CdC_d to match the continuous closed loop, not only CC, at the sampling instants or in a norm.

Pitfalls

  • Slow sampling. The hold costs ωch/2\omega_c h/2 rad of phase whatever map is used. At h=0.2h = 0.2 s the example lost about 25 degrees with Tustin and more with the others.
  • Forward Euler on fast poles. It maps a pole pp to 1+hp1 + hp, which leaves the unit circle when h>2/∣p∣h > 2/|p|.
  • Warping of sharp features. A notch or a resonance moves in frequency with Tustin. Prewarp at that frequency.
  • No anti-aliasing filter. Noise above π/h\pi/h folds down into the band of the loop; the filter itself adds lag that must enter the margin check.
  • Checking only CdC_d against CC. The comparison must include the hold and the exact sampled plant; a CdC_d that matches CC well can still give a poor loop.
  • Numbers at fast sampling. With very small hh, the coefficients of CdC_d in zz are close to each other and lose digits; use the delta operator or a state-space form.

Exercises

  1. Apply Tustin to C=(1+as)/(1+bs)C = (1 + a s)/(1 + b s). (Answer: Cd=(1+2a/h)z+(1−2a/h)(1+2b/h)z+(1−2b/h)C_d = \dfrac{(1 + 2a/h) z + (1 - 2a/h)}{(1 + 2b/h) z + (1 - 2b/h)}.)
  2. For the lead of the example and h=0.2h = 0.2 s, where does forward Euler put the controller pole, and what is the largest hh that keeps it inside the unit circle? (Answer: 1−0.2/0.11321=−0.7671 - 0.2/0.11321 = -0.767; h<2×0.11321=0.2264h < 2 \times 0.11321 = 0.2264 s.)
  3. At h=0.1h = 0.1 s, to which discrete frequency does Tustin map the continuous frequency 4.41659 rad/s? (Answer: ωd=(2/h)arctan⁡(ωh/2)=4.347\omega_d = (2/h) \arctan(\omega h/2) = 4.347 rad/s.)
  4. Use the rule to predict the phase margin with Tustin at h=0.05h = 0.05 s. (Answer: ωch/2=0.1104\omega_c h/2 = 0.1104 rad =6.33= 6.33 degrees, so 43.30 degrees, as measured.)
  5. Compute the prewarped constant for ω0=4.41659\omega_0 = 4.41659 rad/s at h=0.1h = 0.1 s, and compare it with 2/h2/h. (Answer: ω0/tan⁡(ω0h/2)=19.674\omega_0/\tan(\omega_0 h/2) = 19.674, against 20.)

References

  1. Arnold Tustin, A method of analysing the behaviour of linear systems in terms of time series, Journal of the Institution of Electrical Engineers, Part IIA 94(1) (1947) 130-142, the whole paper (the bilinear substitution)
  2. Karl Johan Åström and Björn Wittenmark, Computer-Controlled Systems, third edition, Prentice Hall, 1997, Chapter 8 (approximation of continuous-time controllers)

About this page

The build computes these levels from the evidence in the repository. Each row says what the next level needs. Read what the levels mean.

LadderLevelWhat the next level needs
Human proofH0 no proof
  • add a proof in proofs/ (06.5)
LeanL0 no Lean part
  • name a Lean module in the lean field (07)
VisualV0 none
  • add viz/scene.ts or a figure (10)
WritingW3 standard